CYROLITE MD ZK6 High Impact Medical Acrylic USP VI

基础信息

品名
CYROLITE MD ZK6 High Impact Medical Acrylic USP VI
牌号
CYROLITE MD ZK6
厂商
Röhm GmbH
材料类型
PMMA-based copolymer
产品形态
Pellets
特点
3x impact resistance, bonds to PVC, ultrasonic/laser weldable, USP VI

描述


CYROLITE MD ZK6 High Impact Medical Acrylic USP VI

Grade: CYROLITE MD ZK6
Material: Impact Modified PMMA
MFR: 1.7 g/10min
Impact: 3x Unmodified Acrylic
Transmission: 91.5%
Haze: 1%
Packing: 1500 lb boxes
🔬 High Impact Highlight
CYROLITE MD ZK6 delivers 3 times the impact resistance of unmodified acrylics with 91.5% light transmission, 1% haze, and excellent bonding to PVC tubing — ideal for durable medical devices and diagnostic components.

CYROLITE MD ZK6 is an impact modified thermoplastic injection molding and extrusion compound based on polymethyl methacrylate (PMMA) for the medical industry. It delivers high impact and break resistance with 3 times the impact resistance of unmodified acrylics, combined with medium heat resistance and excellent dimensional stability. The material maintains high light transmission of 91.5% with only 1% haze, ensuring optical clarity for diagnostic applications.

CYROLITE MD ZK6 offers excellent bonding to PVC tubing and can be thermal bonded, ultrasonic welded, and laser welded for reliable assembly of medical devices. It provides improved tensile elongation and is processable on standard injection molding machines and extrusion lines with 3-zone general purpose screws. Meeting USP Class VI (colorless), ISO 10993-1 (colorless), and FDA 21 CFR 176.170 food contact requirements, this material is suitable for a wide range of medical and diagnostic applications.

Genuine Roehm CYROLITE Imported Stock and Technical Support
We supply stable spot inventory of genuine CYROLITE MD ZK6 high impact medical acrylic. Official TDS, batch COA, and biocompatibility documentation (USP Class VI, ISO 10993) are available for medical device applications.

Request CYROLITE MD ZK6 Quotation, TDS, and Sample
Complete TDS, COA, and regulatory documentation available

Core Advantages of CYROLITE MD ZK6

  • 3 times the impact resistance — exceptional durability compared to unmodified acrylics
  • Excellent bonding to PVC tubing — reliable assembly with thermal, ultrasonic, and laser welding
  • High optical clarity — 91.5% light transmission with 1% haze
  • Medium heat resistance — Vicat softening point of 94°C for reliable performance
  • Excellent dimensional stability — precise and consistent component geometry
  • Improved tensile elongation — enhanced ductility for durable medical devices
  • Medical grade compliance — USP Class VI (colorless), ISO 10993-1 (colorless), FDA 21 CFR 176.170
  • Versatile processing — injection molding and extrusion with standard equipment

Main Applications

  • Cassettes — diagnostic test cassettes
  • Test Packs — integrated diagnostic test devices
  • Filter Housings — medical and diagnostic filter components
  • Lenses — optical lenses for diagnostic instruments
  • Microfluidics — precision fluid handling components
  • Guard Clips — protective clips for medical devices
  • Luers and Luer Locks — syringe and fluid connectors
  • Tube Connectors — PVC tubing connection components
  • IV Catheter Hubs — intravenous catheter connection hubs
  • Y Sites — Y-shaped fluid connection sites

Full Technical Parameters

Property Typical Value Test Method
Material Type Impact modified PMMA-based polymer
Medical Compliance USP Class VI (colorless), ISO 10993-1 (colorless), FDA 21 CFR 176.170
Melt Flow Rate (230°C/3.8kg) 1.7 g/10min ASTM D1238
Light Transmission (3.2mm) 91.5% ASTM D1003
Haze (3.2mm) 1% ASTM D1003
Tensile Strength 43.4 MPa ASTM D638
Tensile Modulus 1.5 GPa ASTM D638
Tensile Elongation @ Yield 5% ASTM D638
Tensile Elongation @ Break 55% ASTM D638
Flexural Strength 59.3 MPa ASTM D790
Flexural Modulus 1.5 GPa ASTM D790
Notched Izod Impact (23°C) 58.1 J/m ASTM D256
Notched Izod Impact (0°C) 36.8 J/m ASTM D256
Rockwell Hardness 40 M Scale ASTM D785
Vicat Softening Point 94°C ASTM D1525
HDT (1.8 MPa) 90°C ASTM D648
Specific Gravity 1.16 ASTM D792
Water Absorption 0.3% max ASTM D570
Mold Shrinkage 0.004-0.007 in/in ASTM D955
Bulk Density 0.71 g/cc ASTM D1895
Impact Resistance 3x unmodified acrylics
Bonding Excellent bonding to PVC tubing

Note: All listed figures are typical values and may vary by production batch. Complete independent qualification testing is required before mass production deployment.

Recommended Processing Conditions

Parameter Recommended Value
Processing Method Injection Molding, Extrusion
Screw Type 3-zone general purpose screw
Drying Temperature 180-190°F (82-88°C)
Drying Time 3-4 hours
Melt Temperature 440-500°F (227-260°C)
Mold Temperature 120-180°F (49-82°C)

Handling and Storage Recommendations

Storage Rules Store in dry, cool conditions away from direct sunlight and heat sources.
Packaging 1500 lb gaylor boxes; other packaging available on request.
Operation Protection Follow standard safety practices for handling thermoplastic pellets. Use appropriate PPE during processing.

Official Technical Documentation

Document Type Document Introduction Document Request
TDS CYROLITE MD ZK6 original factory technical data sheet Request TDS
COA Batch-specific certificate of analysis Request COA
Biocompatibility USP Class VI and ISO 10993-1 documentation Request Documentation

Frequently Asked Questions

What is CYROLITE MD ZK6?

CYROLITE MD ZK6 is an impact modified medical acrylic with 3x the impact resistance of unmodified acrylics, 91.5% light transmission, 1% haze, and USP Class VI biocompatibility for medical device and diagnostic applications.

What is the melt flow rate of CYROLITE MD ZK6?

CYROLITE MD ZK6 has a melt flow rate of 1.7 g/10min (230°C/3.8kg), which is lower than other MD series grades, making it suitable for applications requiring higher impact strength and structural integrity.

How does CYROLITE MD ZK6 compare to standard acrylic?

CYROLITE MD ZK6 offers 3 times the impact resistance of unmodified acrylics while maintaining excellent optical clarity with 91.5% light transmission, 1% haze, and improved tensile elongation for greater durability in medical devices.

What medical certifications does CYROLITE MD ZK6 hold?

CYROLITE MD ZK6 meets USP Class VI (colorless), ISO 10993-1 (colorless), and FDA 21 CFR 176.170 food contact requirements, making it suitable for medical devices and diagnostic components.

Can CYROLITE MD ZK6 be bonded to PVC tubing?

Yes. CYROLITE MD ZK6 offers excellent bonding to PVC tubing and can be thermal bonded, ultrasonic welded, and laser welded for assembly of medical devices.

What applications is CYROLITE MD ZK6 suitable for?

CYROLITE MD ZK6 is ideal for injection molded medical devices including cassettes, test packs, filter housings, lenses, microfluidics, guard clips, luers, luer locks, tube connectors, IV catheter hubs, and Y sites.

Related CYROLITE Products

Compare CYROLITE medical diagnostic polymers for different application requirements.

Product Key Feature MFR HDT Impact Core Application
ZK6 3x impact + bonds to PVC 1.7 90°C 58.1 J/m IV hubs, connectors, housings
L40 Highest flow + lubricant 26.0 74°C 19 J/m Thin-wall diagnostics
H12 High flow + UV transparency 7.0 95°C Cuvettes, microfluidics
H15 High heat + high melt strength 2.2 96°C Well plates, test packs

Get CYROLITE MD ZK6 Bulk Pricing and Technical Support

We supply genuine CYROLITE MD ZK6 high impact medical acrylic for medical device and diagnostic applications. Contact us for bulk pricing, sample availability, technical documents, and application support.

Request CYROLITE MD ZK6 Technical Details

Disclaimer: All technical data on this page are for general guidance only and are not product specifications. Buyers must carry out independent trials and verify suitability before bulk ordering. Actual values may vary between production lots.

Technical Documents

Download technical data sheets, safety data sheets and certificates for this material.

TDS Files

Technical document available for review or download.

1 Files

MSDS Files

Technical document available for review or download.

0 Files
No MSDS file uploaded yet.