ULTEM HU1110 – Enhanced Flow Healthcare Grade PEI Resin by SABIC

基础信息

品名
ULTEM Resin HU1110
牌号
HU1110
厂商
SABIC (Saudi Basic Industries Corporation)
材料类型
Polyetherimide (PEI) – Unreinforced, Amorphous
产品形态
Resin Pellets
特点
Enhanced flow healthcare PEI (Tg 217°C); biocompatible (ISO 10993 or USP Class VI); steam, gamma, EtO, and E-beam sterilizable; FDA & EU food contact compliant; UL94 V-0 & 5VA; high stiffness and strength; hydrolytic stability; chemical resistance; low smoke and toxicity; good dimensional stability; ECO conforming; PFAS-free

描述

ULTEM Resin HU1110 is an enhanced flow, healthcare grade polyetherimide (PEI) resin manufactured by SABIC. As an authorized distributor and trader, we supply genuine SABIC materials with full traceability. For more product options and company information, please visit our website at https://szrqchem.com/.

ULTEM HU1110 is an unreinforced, amorphous PEI resin specifically developed for medical devices and pharmaceutical applications. It features a glass transition temperature of 217°C and enhanced flow characteristics for easier processing of complex, thin-walled parts.

This grade is biocompatible per ISO 10993 or USP Class VI and supports multiple sterilization methods including steam, gamma irradiation, ethylene oxide (EtO), and E-beam. It is FDA and EU food contact compliant and ECO conforming.

With its inherent flame retardancy (UL94 V-0 and 5VA), high stiffness, enhanced flow, hydrolytic stability, and chemical resistance, ULTEM HU1110 is the trusted choice for demanding healthcare environments where performance, safety, and reliability are critical. It is also suitable for additive manufacturing (3D printing).

Key Features of ULTEM HU1110

  • Healthcare Grade – Specifically developed for medical devices and pharmaceutical applications; biocompatible (ISO 10993 or USP Class VI)

  • Enhanced Flow – Improved flow characteristics (MFR 16 g/10min, MVR 21 cm³/10min) for easier processing and better mold filling of complex, thin-walled parts

  • Multiple Sterilization Compatibility – Supports steam, gamma irradiation, ethylene oxide (EtO), and E-beam sterilization

  • High Heat Resistance – Glass transition temperature of 217°C; HDT of 210°C at 1.80 MPa

  • Inherent Flame Retardancy – UL94 V-0 (0.75mm)V-2 (0.4mm), and 5VA ratings

  • High Stiffness & Strength – Tensile modulus of 3,500 MPa; tensile yield strength of 110 MPa

  • Excellent Dimensional Stability – Low shrinkage (0.50-0.70%) and low creep sensitivity

  • Food Contact Compliant – FDA and EU food contact compliant

  • Good Chemical Resistance – Excellent resistance to automotive fluids, aircraft fluids, aliphatic hydrocarbons, alcohols, acids, and weak aqueous solutions

  • Hydrolytic Stability – Good resistance to moisture and hydrolysis

  • Low Smoke & Low Toxicity – Inherently low smoke and toxicity

  • ECO Conforming – Meets environmental compliance standards

  • PFAS-Free – No PFAS intentionally added during manufacturing

  • Versatile Processing – Suitable for injection molding; also compatible with additive manufacturing (3D printing)

Comparison: ULTEM HU1100 vs ULTEM HU1110

Property ULTEM HU1100 ULTEM HU1110
Flow Type Standard Flow Enhanced Flow
MFR (337°C/6.6kg) 8.8 g/10min 16 g/10min
MVR (360°C/5kg) 16 cm³/10min 21 cm³/10min
Density (ISO) 1.27 g/cm³ 1.27 g/cm³
Tg 217°C 217°C
HDT (1.80 MPa) 188°C 210°C
Tensile Modulus 3,200 MPa 3,500 MPa
Yield Stress 105 MPa 110 MPa
UL 94 V-2 (0.4mm), 5VA V-0 (0.75mm), V-2 (0.4mm), 5VA
Key Feature Standard flow Enhanced flow + higher HDT + higher stiffness

ULTEM HU1110 offers enhanced flow for easier processing, a higher heat deflection temperature (210°C vs 188°C) , and higher stiffness (3,500 MPa vs 3,200 MPa) compared to HU1100, while maintaining the same healthcare-grade biocompatibility and sterilization capabilities.

Typical Applications for ULTEM HU1110

Industry Typical Applications
Surgical Devices Surgical instruments, reusable medical devices – withstands multiple sterilization cycles
Pharmaceutical Packaging & Drug Delivery Drug delivery systems, pharmaceutical packaging – biocompatible, FDA compliant
Ophthalmics Ophthalmic surgical instruments and devices
Sterilization Trays & Containers Sterilization trays, containers – supports steam, gamma, EtO, and E-beam sterilization
Respiratory & Sleep Therapy Respiratory devices, sleep therapy equipment
Fluid & Blood Handling Fluid handling components, blood handling devices
Medical Facility Infrastructure Healthcare facility infrastructure components
Laboratory Ware & Clinical Diagnostics Lab ware, clinical diagnostics equipment
Personal Accessories Personal healthcare accessories
Additive Manufacturing 3D printed medical device prototypes and components

Typical Properties

Property HU1110 (ISO) HU1110 (ASTM) Unit Test Method
Physical
Density 1.27 1.36 g/cm³ ISO 1183 / ASTM D792 
Melt Volume Rate (MVR) – 360°C/5kg 21 cm³/10min ISO 1133 
Melt Flow Rate (MFR) – 337°C/6.6kg 16 g/10min ASTM D1238 
Mold Shrinkage, Flow (3.2mm) 0.50 – 0.70 %
Mechanical
Tensile Modulus 3,500 MPa ISO 527 
Tensile Strength (Yield) 110 110 MPa ISO 527 / ASTM D638 
Tensile Strength (Break) MPa
Yield Strain 6 % ISO 527 
Elongation at Break 50 % ISO 527 
Flexural Modulus 3,300 MPa ISO 178 
Impact
Izod Impact (Notched, 23°C) 4 kJ/m² ISO 180/1A 
Izod Impact (Notched, -30°C) 4 kJ/m² ISO 180/1A 
Charpy Impact (Notched, 23°C) 5 kJ/m² ISO 179/1eA 
Ball Indentation Hardness 145 MPa ISO 2039-1 
Thermal
Glass Transition Temperature (Tg) 217 217 °C
Heat Deflection Temp. (1.80 MPa) 210 °C ISO 75-1/-2 
Vicat Softening Temp. (A) 210 °C ISO 306 
Vicat Softening Temp. (B) 200 °C ISO 306 
Vicat Softening Temp. (120°C/h 50N) 205 °C ISO 306 
UL RTI (Elec/Imp/Str) 170 / 170 / 170 °C UL 746 
Flammability
UL 94 Flammability V-0 (0.75mm), V-2 (0.4mm), 5VA UL 94 
Glow Wire Flammability Index (GWFI, 3.2mm) 960 °C IEC 60695-2-12 
Other
Water Absorption (Saturation) 1.2 % ISO 62 

Important Notes on Typical Data:

  • Values listed are typical and sourced from SABIC official data sheets. They do not constitute binding product specification.

  • Batch-to-batch deviations may exist. For critical applications, validate performance with batch-specific COA certificate.

  • Final performance depends on processing conditions, mold design, and part geometry.

  • SABIC official TDS shall serve as definitive technical reference. Request the latest official TDS from our sales team.

Processing Guidelines (Injection Molding)

Parameter Recommended Conditions
Drying
Drying Temperature 150°C 
Drying Time 4 – 6 hours 
Maximum Moisture Content ≤0.02% 
Injection Molding
Suggested Shot Size 40 – 60% of cylinder capacity 
Rear Temperature
Middle Temperature
Front Temperature
Nozzle Temperature
Processing (Melt) Temperature 350 – 400°C 
Mold Temperature 135 – 165°C 
Back Pressure 0.3 – 0.7 MPa 
Screw Speed 40 – 70 rpm 
Vent Depth 0.025 – 0.076 mm 

Critical Processing Warnings:

  • Drying: ULTEM HU1110 is hygroscopic and must be dried to ≤0.02% moisture before processing. Dry at 150°C for 4-6 hours.

  • Enhanced Flow: This grade offers enhanced flow characteristics (MFR 16 g/10min, MVR 21 cm³/10min) for easier processing and better mold filling of complex, thin-walled parts.

  • Melt Temperature: Recommended melt temperature range is 350-400°C. Avoid excessive residence times to prevent thermal degradation.

  • Mold Temperature: Higher mold temperatures (135-165°C) improve flow and reduce residual stress.

  • Healthcare Applications: This grade is specifically designed for medical devices and pharmaceutical applications. It is biocompatible (ISO 10993 or USP Class VI) and healthcare management of change applies.

  • Sterilization: ULTEM HU1110 supports steam, gamma, EtO, and E-beam sterilization. Verify compatibility with your specific sterilization protocol.

  • Food Contact: This material is food contact compliant in most jurisdictions – exceptions may exist, request a declaration for details.

  • PFAS-Free: This product does not contain PFAS intentionally added during manufacturing.

  • Gate Design: Use large gates and runners to minimize flow resistance and reduce molded-in stress.

  • Regrind: Regrind can be used up to 20-25% with virgin material, provided it is clean and properly dried.

Related Products

Technical Documents

Document Type Description & Source
SABIC Official TDS Complete physical, thermal, and mechanical properties of ULTEM HU1110
SABIC Official SDS GHS-compliant chemical safety documentation
UL Yellow Card UL certification E121562-100044748 
ISO 10993 / USP Class VI Biocompatibility certification 
FDA Compliance Declaration FDA food contact compliance 
EU Food Contact Compliance European food contact compliance 
COA (Certificate of Analysis) Batch-specific quality certification
Processing Guide Detailed processing guidelines for ULTEM HU1110

Request any document above by:

We reply within one working business day. Please clearly state product (ULTEM HU1110) and document type you require.

FAQ

Q1: What is ULTEM HU1110 and what is it used for?
A: ULTEM HU1110 is an enhanced flow, healthcare grade polyetherimide (PEI) resin manufactured by SABIC. It is specifically developed for medical devices and pharmaceutical applications. It is widely used in surgical instruments, pharmaceutical packaging, drug delivery systems, sterilization trays, laboratory ware, ophthalmics, respiratory & sleep therapy devices, fluid & blood handling components, and general healthcare equipment.

Q2: Is ULTEM HU1110 biocompatible?
A: Yes. ULTEM HU1110 is biocompatible per ISO 10993 or USP Class VI, making it suitable for regulated medical and pharmaceutical applications.

Q3: Is ULTEM HU1110 FDA compliant?
A: Yes. ULTEM HU1110 is FDA and EU food contact compliant. It is food contact compliant in most jurisdictions – exceptions may exist, request a declaration for details.

Q4: What sterilization methods can ULTEM HU1110 withstand?
A: ULTEM HU1110 supports steam sterilization, gamma irradiation, ethylene oxide (EtO), and E-beam sterilization.

Q5: What is the glass transition temperature of ULTEM HU1110?
A: The glass transition temperature (Tg) is 217°C.

Q6: What is the density of ULTEM HU1110?
A: Density is 1.27 g/cm³ (ISO 1183)  and specific gravity is 1.36 g/cm³ (ASTM D792) .

Q7: Is ULTEM HU1110 flame retardant?
A: Yes. ULTEM HU1110 is inherently flame retardant with UL94 V-0 (0.75mm) , V-2 (0.4mm) , and 5VA ratings.

Q8: Is ULTEM HU1110 transparent?
A: Yes. ULTEM HU1110 is transparent, with all colors customizable.

Q9: Is ULTEM HU1110 PFAS-free?
A: Yes. ULTEM HU1110 has no PFAS intentionally added during manufacturing.

Q10: What is the melt flow rate of ULTEM HU1110?
A: The Melt Flow Rate (MFR) is 16 g/10min at 337°C, 6.6kg; the Melt Volume Rate (MVR) is 21 cm³/10min at 360°C, 5kg.

Q11: What is the tensile strength of ULTEM HU1110?
A: Tensile yield strength is 110 MPa.

Q12: What is the tensile modulus of ULTEM HU1110?
A: The tensile modulus is 3,500 MPa.

Q13: What is the heat deflection temperature of ULTEM HU1110?
A: Heat deflection temperature is 210°C at 1.80 MPa.

Q14: What is the difference between ULTEM HU1100 and ULTEM HU1110?
A: ULTEM HU1110 offers enhanced flow (MFR 16 vs 8.8 g/10min), a higher heat deflection temperature (210°C vs 188°C) , and higher stiffness (3,500 MPa vs 3,200 MPa) compared to HU1100, while maintaining the same healthcare-grade biocompatibility and sterilization capabilities.

Q15: What processing methods can be used for ULTEM HU1110?
A: ULTEM HU1110 is suitable for injection molding and is also compatible with additive manufacturing (3D printing) .

Q16: What is the recommended drying condition for ULTEM HU1110?
A: Dry at 150°C for 4-6 hours.

Q17: What is the recommended melt temperature for injection molding ULTEM HU1110?
A: Recommended melt temperature is 350-400°C.

Q18: What is the recommended mold temperature for ULTEM HU1110?
A: Recommended mold temperature is 135-165°C.

Q19: What is the lead time for orders?
A: Regular orders ship within 7-10 working days after payment confirmation. Large-volume or urgent orders can be negotiated separately.

CTA (Call to Action)

Ready to order ULTEM HU1110?

To get a precise quotation and professional technical support, please share:

  • Required quantity (kg)

  • Destination port or delivery address

  • Target application (surgical devices, pharmaceutical packaging, drug delivery, ophthalmics, respiratory, fluid handling, medical devices, etc.)

  • Processing method (injection molding, additive manufacturing, etc.)

  • Color requirement (transparent or custom color)

  • Document requirement (TDS, SDS, ISO 10993/USP Class VI certification, FDA compliance, UL, COA, etc.)

Sample Policy:

  • Samples are for laboratory validation tests only, not for production use.

  • Buyer bears international sample-shipping freight.

  • If bulk-product performance deviates from sample reference, SABIC official TDS serves as the authoritative benchmark.

Take action now:

  • 📧 Email Us – ruiqingchem@gmail.com

  • 📝 Send Inquiry – Use our quick inquiry form

  • 💬 Live Chat – Click the bottom-right chat widget to speak directly with our team

After-Sales Support

Service Details
Quality Inspection Period All quality-related claims must be submitted within 7 working-days after delivery, supported by test data and photographic evidence.
Return / Exchange Policy Confirmed product defects caused by our side trigger replacement or refund. Terms and conditions apply.
Logistics Damage Report shipping damage directly to carrier immediately upon goods receipt. We assist with claim-document preparation.
Technical Support Remote technical guidance available. On-site troubleshooting can be arranged upon special request.
Export Documentation We supply commercial invoice, packing list, bill of lading, COA, and additional compliance certificates (e.g., FDA, ISO 10993, USP Class VI, UL, RoHS) on request.

Disclaimer

DISCLAIMER: All technical data is referenced from original SABIC typical values for ULTEM HU1110. Our company acts as authorized distributor/trader rather than original manufacturer. Final performance depends on processing conditions, mold design, and part geometry. Buyers shall independently validate product suitability for individual applications, particularly for medical device applications where regulatory compliance must be verified under end-use conditions. Our firm bears no liability for product failure caused by improper processing or improper usage. Always reference the latest SABIC official TDS of ULTEM HU1110 as the definitive specification.

Technical Documents

Download technical data sheets, safety data sheets and certificates for this material.

TDS Files

Technical document available for review or download.

1 Files

MSDS Files

Technical document available for review or download.

0 Files
No MSDS file uploaded yet.