Hostaform MT2U01 – Medical Grade High Molecular Weight POM-C

基础信息

品名
Hostaform MT2U01
牌号
MT2U01
厂商
Celanese
材料类型
Polyoxymethylene (POM) Copolymer
产品形态
Resin Pellets
特点
High molecular weight grade for healthcare market with improved toughness, low residual monomers, and no animal-derived constituents

描述

Hostaform MT2U01 is a high molecular weight, medical grade POM‑C (Polyoxymethylene Copolymer) developed by Celanese for healthcare market applications. As an authorized distributor and trader, we supply genuine material with full traceability and direct access to official Celanese technical documentation.

This unfilled acetal copolymer is a low melt flow, high molecular weight grade (MVR 2.5 cm³/10min) designed for extrusion and injection molding. The high molecular weight provides excellent melt strength and mechanical properties for demanding applications.

Hostaform MT2U01 is a special grade developed for medical industry applications, containing low residual monomers and no animal-derived constituents. It is a low melt flow injection molding and extrusion grade designed for good processing along with optimum properties including improved toughness in demanding applications.

We hold regular stock, supporting small trial orders and large‑volume bulk shipments for medical and healthcare end‑users.

Key Features of Hostaform MT2U01

  • High Molecular Weight / Low Melt Flow – MVR of 2.5 cm³/10min (190°C/2.16kg), providing excellent melt strength for extrusion and demanding applications

  • Medical Grade Compliance – Developed specifically for medical industry applications

  • Low Residual Monomers – Contains low residual monomers suitable for sensitive medical applications

  • No Animal-Derived Constituents – Formulated without animal products

  • Improved Toughness – Designed for optimum properties including improved toughness in demanding applications

  • High Stiffness – Tensile modulus of 2600 MPa

  • Good Strength – Yield stress of 62 MPa

  • Excellent Impact Resistance – Charpy notched impact strength of 8.5 kJ/m² at 23°C and 7 kJ/m² at -30°C

  • High Unnotched Impact Strength – Charpy impact strength of 250 kJ/m² at 23°C and -30°C

  • Good Heat Resistance – Melting temperature of 165°C and heat deflection temperature of 101°C at 1.8 MPa

  • Good Dimensional Stability – Molding shrinkage: parallel 2.1%, normal 1.8%

  • Versatile Processing – Suitable for injection molding, profile extrusion, and sheet extrusion

  • Contains Release Agent – Facilitates easy demolding during processing

  • Regional Availability – Available in Africa & Middle East, Asia Pacific, Europe, North America

Typical Applications for Hostaform MT2U01

Industry Typical Components & Considerations
Medical & Healthcare Medical devices, surgical instruments, drug delivery devices, diagnostic equipment components. High molecular weight provides excellent mechanical properties and toughness for demanding healthcare applications.
Medical / Healthcare Extrusion Extruded profiles, sheets, and tubing for medical applications. Low melt flow/high molecular weight provides excellent melt strength for extrusion processing.
Medical Injection Molding Injection molded medical components requiring high toughness and biocompatibility
Automotive Gears, bearings, fuel system components requiring high toughness and chemical resistance
Electrical & Electronics Connectors, switches, precision housings requiring dimensional stability
Industrial Machinery Gears, cams, guide rails, pump valves, conveyor rollers, fasteners

Explore our full range of engineering plastics solutions for more industry‑specific case studies. See also our full POM product portfolio .

Material Advantages of Hostaform MT2U01

What makes Hostaform MT2U01 the preferred material for medical and healthcare applications? Below are its core practical advantages:

High Molecular Weight for Superior Properties
With high molecular weight and low melt flow (MVR 2.5 cm³/10min), Hostaform MT2U01 provides excellent melt strength for extrusion processing and superior mechanical properties including improved toughness for demanding applications.

Medical Grade Compliance
This grade is developed specifically for medical industry applications. It contains low residual monomers and no animal-derived constituents, making it suitable for sensitive healthcare applications.

Excellent Mechanical Properties
With a tensile modulus of 2600 MPa, yield stress of 62 MPa, and nominal strain at break of 32%, this material delivers reliable structural performance.

Outstanding Impact Resistance
Charpy notched impact strength of 8.5 kJ/m² at 23°C and 7 kJ/m² at -30°C, plus Charpy unnotched impact strength of 250 kJ/m² at both temperatures, ensure exceptional durability.

Good Thermal Properties
Melting temperature of 165°C and heat deflection temperature of 101°C at 1.8 MPa ensure thermal stability during processing and service.

Versatile Processing Capabilities
Hostaform MT2U01 is suitable for multiple processing methods including injection molding, profile extrusion, and sheet extrusion.

Good Dimensional Stability
Molding shrinkage: parallel 2.1%, normal 1.8%. CLTE of 110 E-6/K ensures predictable dimensional behavior.

Biocompatible
Hostaform MT2U01 is designed for healthcare market applications with appropriate biocompatibility characteristics.

Heavy‑Metal Free
Environmentally friendly formulation.

Batch‑to‑Batch Consistency
Celanese manufactures this grade under strict ISO quality standards for consistent property across shipments.

Reliable Supply
We maintain active inventory and stable supply chains. For more supply‑chain details, visit our company background page .

Typical Properties (ISO Standards)

Typical properties of Hostaform MT2U01 measured to ISO standards are listed below:

Property Test Standard Typical Value Unit
Physical Properties
Density ISO 1183 1410 kg/m³
Melt Volume Flow Rate (MVR) ISO 1133 (190°C/2.16kg) 2.5 cm³/10min
Molding Shrinkage, Parallel ISO 294-4, 2577 2.1 %
Molding Shrinkage, Normal ISO 294-4, 2577 1.8 %
Water Absorption (23°C/sat) Sim. to ISO 62 0.65 %
Humidity Absorption (23°C/50% RH) Sim. to ISO 62 0.2 %
Mechanical Properties
Tensile Modulus ISO 527 2600 MPa
Yield Stress ISO 527 62 MPa
Yield Strain ISO 527 9 %
Nominal Strain at Break ISO 527 32 %
Charpy Unnotched Impact (23°C) ISO 179/1eU 250 kJ/m²
Charpy Unnotched Impact (-30°C) ISO 179/1eU 250 kJ/m²
Charpy Notched Impact (23°C) ISO 179/1eA 8.5 kJ/m²
Charpy Notched Impact (-30°C) ISO 179/1eA 7 kJ/m²
Thermal Properties
Melting Temperature ISO 11357-1/-3 165 °C
Heat Deflection Temp (1.8 MPa) ISO 75-1/-2 101 °C
CLTE, Parallel ISO 11359-1/-2 110 E-6/K

Important Notes on Typical Data:

  1. Values listed are typical and sourced from Celanese official data sheets for Hostaform MT2U01. They do not constitute binding product specification.

  2. Batch‑to‑batch deviations may exist. For critical applications, validate performance with batch‑specific COA certificate.

  3. Final part performance depends on component design, processing parameters and end‑use environment.

  4. Celanese original TDS shall serve as definitive technical reference. Request the latest official Hostaform MT2U01 TDS from our sales team.

Processing Guidelines (Injection Molding & Extrusion)

Recommended processing parameters for Hostaform MT2U01:

Parameter Recommended Setting
Drying Recommended Recommended for medical grade applications
Drying Temperature 100 – 120°C
Drying Time (Dehumidified Dryer) 3 – 4 hours
Max. Processing Moisture Content ≤0.2%
Optimum Melt Temperature 190 – 210°C
Optimum Mold Temperature 80 – 120°C
Hold Pressure Range 60 – 120 MPa
Back Pressure 4 MPa

Critical Processing Warnings for Hostaform MT2U01:

  • Extrusion Considerations: With low melt flow/high molecular weight (MVR 2.5 cm³/10min), Hostaform MT2U01 is designed for extrusion processing including profile extrusion and sheet extrusion. Adjust extrusion parameters (die design, melt temperature, draw ratio) accordingly for optimal results.

  • Injection Molding: Suitable for injection molding of medical components requiring high toughness and biocompatibility.

  • Medical Grade Purity: Strictly prevent cross‑contamination with other polymer grades or non-medical materials. Contamination will compromise the medical compliance and biocompatibility of the material.

  • Drying: Drying is recommended for this medical grade material to achieve optimal performance and part quality. If material has come into contact with moisture through improper storage or handling, drying is necessary to prevent splay and odor.

  • Thermal Degradation Risk: POM‑based material can decompose under excessive heat and release formaldehyde vapors. Guarantee sufficient ventilation; avoid overly long barrel residence times.

  • Regrind / Recycled Material Notice: We do not recommend adding regrind for this medical grade specialty material. Reprocessing may compromise the biocompatibility, mechanical properties, and medical compliance. If regrind usage is mandatory, keep percentage below 10% and complete pre‑validation testing first.

  • Storage Guidance: Store pellets in cool, dry conditions; keep sealed in original factory packaging whenever possible to maintain low residual monomer content.

Related Products

Technical Documents

We provide complete supporting documentation for material selection and compliance verification.

Document Type Description & Source
Celanese Official TDS Complete physical, thermal, mechanical and processing properties of Hostaform MT2U01, issued by Celanese original.
Celanese Official SDS GHS‑compliant chemical safety documentation, original Celanese document.
Celanese Distributor Authorization Certificate Proof of our authorized‑distributor qualification for Celanese Hostaform series, available upon request.
Biocompatibility Documentation Medical compliance documentation for healthcare applications.
RoHS / REACH Compliance Declarations Available upon customer request.
Processing & Molding/Extrusion Guide Detailed processing operation guidance for medical grade high molecular weight POM.

Request any document above by:

  • Email: ruiqingchem@gmail.com

  • Online form: Our contact page

We reply within one working business day. Please clearly state material grade (Hostaform MT2U01) and document type you require.

External Reference

For further authoritative information, please visit the official Celanese Hostaform product portal and download the latest datasheet for Hostaform MT2U01.

Major technical standards referenced inside this article:

  • ISO 1043-1 / ISO 11469 – Resin identification and part marking

  • ISO 1183 – Density measurement

  • ISO 527 – Tensile properties

  • ISO 179/1eU / 1eA – Impact resistance

  • ISO 75-1/-2 – Heat deflection temperature

  • ISO 1133 – Melt volume-flow rate

  • ISO 11357-1/-3 – Melting temperature

  • ISO 294-4, 2577 – Mold shrinkage

  • ISO 11359-1/-2 – Coefficient of linear thermal expansion

  • ISO 62 – Water/humidity absorption

Our technical team can supply relevant standard excerpts for your engineering reference.

FAQ

Q1: What is Hostaform MT2U01 and what is it used for?
A: Hostaform MT2U01 is a high molecular weight, medical grade POM‑C (Polyoxymethylene Copolymer) developed by Celanese for the healthcare market. It is a low melt flow grade designed for extrusion and injection molding with improved toughness in demanding applications. It is widely used in medical devices, surgical instruments, drug delivery devices, diagnostic equipment components, extruded medical profiles, sheets, and tubing.

Q2: What does “MT2U01” mean in the grade name?
A: MT indicates Medical Technology grade; 2 denotes the product series with high molecular weight / low melt flow characteristics; U indicates the specific formulation variant within the medical series; 01 denotes the specific grade iteration.

Q3: What makes this grade different from standard POM grades?
A: Hostaform MT2U01 is a high molecular weight medical grade with low melt flow (MVR 2.5 cm³/10min) providing excellent melt strength for extrusion. It contains low residual monomers and no animal‑derived constituents, making it suitable for healthcare applications. It also offers improved toughness for demanding applications.

Q4: What are the key mechanical properties?
A: Tensile modulus 2600 MPa, yield stress 62 MPa, yield strain 9%, nominal strain at break 32%, Charpy notched impact strength 8.5 kJ/m² (23°C) / 7 kJ/m² (-30°C), Charpy unnotched impact strength 250 kJ/m², melting temperature 165°C, and heat deflection temperature 101°C at 1.8 MPa.

Q5: What is the MVR?
A: Melt‑volume‑flow‑rate equals 2.5 cm³/10min measured under 190°C / 2.16 kg test condition.

Q6: What processing methods is this material suitable for?
A: Hostaform MT2U01 is suitable for injection molding, profile extrusion, and sheet extrusion.

Q7: Is this material biocompatible?
A: Yes, Hostaform MT2U01 is a special grade developed for medical industry applications with appropriate biocompatibility characteristics for healthcare applications.

Q8: Does this material contain animal-derived products?
A: No, Hostaform MT2U01 is formulated with no animal-derived constituents.

Q9: Is drying required before processing?
A: Drying is recommended for this medical grade material. If material has come into contact with moisture through improper storage or handling, drying is necessary to prevent splay and odor.

Q10: What regions is this material available in?
A: Hostaform MT2U01 is available in Africa & Middle East, Asia Pacific, Europe, and North America.

Q11: Can I buy this material and what is lead‑time?
A: Yes. Submit your inquiry via our quick inquiry form or email ruiqingchem@gmail.com, specify quantity, application and delivery address. Regular orders 1‑5 tons ship within 7‑10 working days after payment confirmation. Large‑volume or urgent orders can be negotiated separately.

Q12: What are limitations?
A: POM‑C does not resist strong mineral acids, powerful oxidizing agents, or continuous exposure to hot water >80°C. Consult our technical team for chemical‑compatibility data for your exact working environment.

CTA (Call to Action)

Ready to order Hostaform MT2U01?

To get precise quotation and professional technical support, please share these details:

  • Required quantity (kg or tons)

  • Destination port or delivery address

  • Target application and part brief (medical device, extrusion profile, injection molded component, etc.)

  • Core performance requirements (high molecular weight, toughness, biocompatibility, etc.)

  • Document requirement (TDS, SDS, biocompatibility documentation, compliance certificates, etc.)

Sample Policy:

  • Samples are for laboratory validation tests only, not for mass‑production use.

  • Buyer bears international sample‑shipping freight.

  • If bulk‑material performance deviates from sample reference, Celanese official TDS serves as authoritative benchmark.

Take action now:

  • Send Inquiry – Use our quick inquiry form

  • Email Us – ruiqingchem@gmail.com

  • Live Chat – Click bottom‑right chat widget to speak directly with our team

After-Sales Support

Service Details
Quality Inspection Period All quality‑related claims must be submitted within 7 working‑days after delivery, supported by test data and photographic evidence.
Return / Exchange Policy Confirmed material defects caused by our side trigger replacement or refund. Terms and conditions apply. Please check our full Terms & Conditions.
Logistics Damage Report shipping damage directly to carrier immediately upon goods receipt. We assist with claim‑document preparation.
Technical Support Remote technical guidance available. On‑site extrusion or molding troubleshooting service can be arranged upon special request.
Export Documentation We supply standard export documents: commercial invoice, packing list, bill of lading, COA. Additional compliance certificates (e.g., biocompatibility documentation) can be provided on request.

Disclaimer

DISCLAIMER: All technical data is referenced from original Celanese typical values for Hostaform MT2U01. Our company acts as authorized distributor/trader rather than original manufacturer. Final component performance depends on part geometry, processing setup and end‑use environment. Buyers shall independently validate material suitability for individual applications, particularly for medical device applications where regulatory compliance and biocompatibility testing are required. Our firm bears no liability for finished‑part failure caused by improper design or improper processing. Always reference latest Celanese official TDS of Hostaform MT2U01 as definitive specification.