描述
Hostaform MT24U01 is a high flow, medical grade POM‑C (Polyoxymethylene Copolymer) injection molding grade, genuinely manufactured by Celanese and imported as original product. As an authorized distributor and trader, we supply genuine material with full traceability and direct access to official Celanese technical documentation.
This unfilled acetal copolymer is a low melt viscosity grade with very high flow (MVR 24 cm³/10min), designed for fast cycling and thin walled injection molding. The exceptional flowability enables filling of complex, thin wall geometries while maintaining good mechanical properties.
Hostaform MT24U01 is a special grade developed for medical industry applications, containing low residual monomers and no animal‑derived constituents. It complies with ISO 10993 and USP Class VI biocompatibility standards, is FDA 21 CFR and BfR food contact approved, and is listed in the Drug Master File (DMF) and Device Master File (MAF). It also complies with RoHS, PFOS and PFOA regulations and is compatible with Ethylene Oxide (EtO) sterilization and steam sterilization.
We hold regular stock, supporting small trial orders and large‑volume bulk shipments for demanding end‑users.
Key Features of Hostaform MT24U01
-
High Flow / Low Melt Viscosity – MVR of 24 cm³/10min (190°C/2.16kg), providing exceptional flow for thin wall parts and enabling fast cycling
-
Medical Grade Compliance – Developed specifically for medical industry applications
-
Low Residual Monomers – Contains low residual monomers suitable for sensitive medical applications
-
No Animal-Derived Constituents – Formulated without animal products
-
Biocompatible – ISO 10993 and USP Class VI certified
-
FDA & BfR Food Contact Approved – FDA 21 CFR and BfR food contact approved
-
FDA Compliant – Listed in Drug Master File (DMF) and Device Master File (MAF)
-
Sterilizable – Compatible with Ethylene Oxide (EtO) sterilization and steam sterilization
-
High Stiffness – Tensile modulus of 2900 MPa
-
Good Strength – Yield stress of 65 MPa
-
Good Impact Resistance – Charpy notched impact strength of 5.5 kJ/m² at 23°C
-
Good Heat Resistance – Melting temperature of 166°C and heat deflection temperature of 106°C at 1.8 MPa
-
Good Dimensional Stability – Molding shrinkage: parallel 1.9%, normal 1.8%
-
Contains Release Agent – Facilitates easy demolding during processing
-
Sustainable Option – ECO‑B variant uses bio‑based feedstocks via mass‑balance approach
-
Regional Availability – Available in North America, Europe, South and Central America, and Near East/Africa
Typical Applications for Hostaform MT24U01
| Industry | Typical Components & Considerations |
|---|---|
| Medical & Healthcare | Drug delivery devices, inhalers, insulin injection pens, surgical instruments, portable diagnostic medical equipment. Fast cycling and thin wall capability enables high‑volume production of precision components. |
| Medical / Nursing Supplies | Thin walled medical products and nursing supplies |
| Thin Wall Applications | Thin walled parts requiring exceptional flowability and fast cycle times |
| Pharmaceutical | Drug Master File (DMF) listed components and pharmaceutical applications |
| Automotive | Interior components, gears, bearings, fuel system components |
| Electrical & Electronics | Connectors, switches, coil formers, precision housings |
| Industrial Machinery | Gears, cams, guide rails, pump valves, conveyor rollers, fasteners |
| Consumer Goods | Sporting equipment, personal care devices, furniture mechanisms |
Explore our full range of engineering plastics solutions for more industry‑specific case studies. See also our full POM product portfolio .
Material Advantages of Hostaform MT24U01
What makes Hostaform MT24U01 the preferred material for medical and high‑flow applications? Below are its core practical advantages:
High Flow for Fast Cycling & Thin Walls
With an MVR of 24 cm³/10min – the highest flow in the MT series – Hostaform MT24U01 offers exceptional flowability for filling thin wall geometries and enables fast cycling for high‑volume production.
Medical Grade Compliance
This grade is developed specifically for medical industry applications. It complies with ISO 10993 and USP Class VI biocompatibility standards, contains low residual monomers and no animal‑derived constituents, and is FDA 21 CFR and BfR food contact approved with DMF and MAF listings.
Excellent Mechanical Properties
With a tensile modulus of 2900 MPa, yield stress of 65 MPa, and nominal strain at break of 17%, this material delivers reliable structural performance.
Good Impact Resistance
Charpy notched impact strength of 5.5 kJ/m² at both 23°C and -30°C, plus Charpy unnotched impact strength of 170 kJ/m², ensure excellent durability.
Good Thermal Properties
Melting temperature of 166°C and heat deflection temperature of 106°C at 1.8 MPa ensure thermal stability during processing and service.
Sterilizable
Hostaform MT24U01 is compatible with both Ethylene Oxide (EtO) sterilization and steam sterilization.
Food Contact & Regulatory Compliance
Approved for food contact according to FDA 21 CFR and BfR. Complies with RoHS, PFOS and PFOA regulations.
ECO‑B Sustainable Option
The ECO‑B variant uses a mass‑balance approach with biogenic feedstocks to offset fossil‑based raw materials and decrease greenhouse gas emissions.
Heavy‑Metal Free
Environmentally friendly formulation.
Batch‑to‑Batch Consistency
Celanese manufactures this grade under strict ISO quality standards for consistent property across shipments.
Reliable Supply
We maintain active inventory and stable supply chains. For more supply‑chain details, visit our company background page .
Typical Properties (ISO Standards)
Typical properties of Hostaform MT24U01 measured to ISO standards are listed below:
| Property | Test Standard | Typical Value | Unit |
|---|---|---|---|
| Physical Properties | |||
| Density | ISO 1183 | 1410 | kg/m³ |
| Melt Volume Flow Rate (MVR) | ISO 1133 (190°C/2.16kg) | 24 | cm³/10min |
| Molding Shrinkage, Parallel | ISO 294-4, 2577 | 1.9 | % |
| Molding Shrinkage, Normal | ISO 294-4, 2577 | 1.8 | % |
| Water Absorption (23°C/sat) | Sim. to ISO 62 | 0.65 | % |
| Humidity Absorption (23°C/50% RH) | Sim. to ISO 62 | 0.2 | % |
| Mechanical Properties | |||
| Tensile Modulus | ISO 527-1/-2 | 2900 | MPa |
| Yield Stress | ISO 527-1/-2 | 65 | MPa |
| Yield Strain | ISO 527-1/-2 | 7.5 | % |
| Nominal Strain at Break | ISO 527-1/-2 | 17 | % |
| Flexural Modulus | ISO 178 | 2800 | MPa |
| Charpy Unnotched Impact (23°C) | ISO 179/1eU | 170 | kJ/m² |
| Charpy Unnotched Impact (-30°C) | ISO 179/1eU | 170 | kJ/m² |
| Charpy Notched Impact (23°C) | ISO 179/1eA | 5.5 | kJ/m² |
| Charpy Notched Impact (-30°C) | ISO 179/1eA | 5.5 | kJ/m² |
| Tensile Creep Modulus, 1 h | ISO 899-1 | 2500 | MPa |
| Tensile Creep Modulus, 1000 h | ISO 899-1 | 1300 | MPa |
| Thermal Properties | |||
| Melting Temperature | ISO 11357-1/-3 | 166 | °C |
| Heat Deflection Temp (1.8 MPa) | ISO 75-1/-2 | 106 | °C |
| CLTE, Parallel | ISO 11359-1/-2 | 110 | E-6/K |
| Certifications | |||
| Medical Compliance | – | ISO 10993, USP Class VI | – |
| Food Contact | – | FDA 21 CFR, BfR | – |
| Sterilization | – | EtO, Steam (autoclave) | – |
Important Notes on Typical Data:
Values listed are typical and sourced from Celanese official data sheets for Hostaform MT24U01.
Batch‑to‑batch deviations may exist. For critical applications, validate performance with batch‑specific COA certificate.
Final part performance depends on component design, processing parameters and end‑use environment.
Celanese original TDS shall serve as definitive technical reference. Request the latest official Hostaform MT24U01 TDS from our sales team.
Processing Guidelines (Injection Molding)
Recommended processing parameters for Hostaform MT24U01:
| Parameter | Recommended Setting |
|---|---|
| Drying Recommended | Not normally required |
| Drying Temperature (if required) | 100 – 120°C |
| Drying Time (Dehumidified Dryer) | 3 – 4 hours |
| Max. Processing Moisture Content | ≤0.2% |
| Zone 1 Temperature | 170 – 180°C |
| Zone 2 Temperature | 180 – 190°C |
| Optimum Melt Temperature | 190 – 210°C |
| Optimum Mold Temperature | 80 – 120°C |
| Hold Pressure Range | 60 – 120 MPa |
| Back Pressure | 4 MPa |
Critical Processing Warnings for Hostaform MT24U01:
Fast Cycling Capability: With high flow (MVR 24 cm³/10min) – the highest in the MT series – Hostaform MT24U01 is designed for fast cycling and thin walled parts. Adjust cycle parameters to maximize throughput while maintaining part quality.
Drying: Drying is not normally required for this material. If material has come into contact with moisture through improper storage or handling, drying may be necessary to prevent splay and odor problems.
Medical Grade Purity: Strictly prevent cross‑contamination with other polymer grades or non-medical materials. Contamination will compromise the medical compliance and biocompatibility of the material.
Thermal Degradation Risk: POM‑based material can decompose under excessive heat and release formaldehyde vapors. Guarantee sufficient ventilation; avoid overly long barrel residence times.
Regrind / Recycled Material Notice: We do not recommend adding regrind for this medical grade specialty material. Reprocessing may compromise the biocompatibility, mechanical properties, and medical compliance. If regrind usage is mandatory, keep percentage below 10% and complete pre‑validation testing first.
Storage Guidance: Store pellets in cool, dry conditions; keep sealed in original factory packaging whenever possible to maintain low residual monomer content.
Related Products
-
Explore Our Full POM Product Portfolio – Browse all POM copolymer and homopolymer grades we supply
-
Medical Grade POM Grades – Discover other medical compliant POM grades
-
High Flow POM Grades – View grades with exceptional flowability for thin wall applications
-
Hostaform MT12U01 – View the standard flow medical grade
-
Hostaform MT12U03 – View the high stiffness medical grade
-
Hostaform MT24F01 – View the PTFE‑filled medical tribological grade
-
About Our Company – Learn more about our supply capabilities and quality assurance
Technical Documents
We provide complete supporting documentation for material selection and compliance verification.
| Document Type | Description & Source |
|---|---|
| Celanese Official TDS | Complete physical, thermal, mechanical and processing properties of Hostaform MT24U01, issued by Celanese original. |
| Celanese Official SDS | GHS‑compliant chemical safety documentation, original Celanese document. |
| Celanese Distributor Authorization Certificate | Proof of our authorized‑distributor qualification for Celanese Hostaform series, available upon request. |
| ISO 10993 Biocompatibility Report | Biocompatibility certification documentation for medical applications. |
| USP Class VI Certification | USP Class VI biocompatibility compliance documentation. |
| FDA Compliance Declaration | FDA 21 CFR compliance statement; Drug Master File (DMF) and Device Master File (MAF) listings. |
| BfR Food Contact Compliance | Food contact approval documentation. |
| RoHS / REACH / PFOS / PFOA Compliance Declarations | Compliance documentation. |
| Processing & Molding Guide | Detailed molding operation guidance for medical grade high flow POM. |
Request any document above by:
-
Email:
ruiqingchem@gmail.com -
Online form: Our contact page
We reply within one working business day. Please clearly state material grade (Hostaform MT24U01) and document type you require.
External Reference
For further authoritative information, please visit the official Celanese Hostaform product portal and download the latest datasheet for Hostaform MT24U01.
Major technical standards referenced inside this article:
-
ISO 1043-1 / ISO 11469 – Resin identification and part marking
-
ISO 1183 – Density measurement
-
ISO 527-1/-2 – Tensile properties
-
ISO 178 – Flexural properties
-
ISO 179/1eU / 1eA – Impact resistance
-
ISO 75-1/-2 – Heat deflection temperature
-
ISO 1133 – Melt volume-flow rate
-
ISO 11357-1/-3 – Melting temperature
-
ISO 294-4, 2577 – Mold shrinkage
-
ISO 11359-1/-2 – Coefficient of linear thermal expansion
-
ISO 899-1 – Tensile creep modulus
-
ISO 62 – Water/humidity absorption
-
ISO 10993 – Biological evaluation of medical devices
-
USP Class VI – United States Pharmacopeia biocompatibility standard
-
FDA 21 CFR – U.S. Food and Drug Administration food contact regulation
Our technical team can supply relevant standard excerpts for your engineering reference.
FAQ
Q1: What is Hostaform MT24U01 and what is it used for?
A: Hostaform MT24U01 is a high flow, low melt viscosity medical grade POM‑C (Polyoxymethylene Copolymer) developed by Celanese. It is designed for fast cycling and thin walled injection molding. It is widely used in medical and healthcare applications including drug delivery devices, inhalers, insulin injection pens, surgical instruments, portable diagnostic medical equipment, thin walled medical products and nursing supplies, as well as automotive, electrical & electronics, industrial machinery, and consumer goods.
Q2: What does “MT24U01” mean in the grade name?
A: MT indicates Medical Technology grade; 24 denotes the product series and high flow level; U indicates the specific formulation variant within the medical series; 01 denotes the specific grade iteration.
Q3: What makes this grade different from standard POM grades?
A: Hostaform MT24U01 is a medical grade with full ISO 10993 and USP Class VI biocompatibility certification, contains low residual monomers and no animal‑derived constituents, and is FDA 21 CFR and BfR food contact approved with DMF and MAF listings. It also features the highest flow in the MT series (MVR 24 cm³/10min) for fast cycling and thin wall applications.
Q4: What are the key mechanical properties?
A: Tensile modulus 2900 MPa, yield stress 65 MPa, yield strain 7.5%, nominal strain at break 17%, flexural modulus 2800 MPa, Charpy notched impact strength 5.5 kJ/m² (23°C and -30°C), Charpy unnotched impact strength 170 kJ/m², melting temperature 166°C, and heat deflection temperature 106°C at 1.8 MPa.
Q5: What is the MVR?
A: Melt‑volume‑flow‑rate equals 24 cm³/10min measured under 190°C / 2.16 kg test condition.
Q6: What medical certifications does this material hold?
A: This material complies with ISO 10993 (biological evaluation of medical devices) and USP Class VI biocompatibility standards. It is FDA 21 CFR and BfR food contact approved and listed in the Drug Master File (DMF) and Device Master File (MAF).
Q7: Is this material food contact compliant?
A: Yes, Hostaform MT24U01 has Food Contact approval according to BfR and FDA 21 CFR.
Q8: What sterilization methods are compatible with this material?
A: Hostaform MT24U01 is compatible with Ethylene Oxide (EtO) sterilization and steam sterilization (autoclaving).
Q9: Is drying required before processing?
A: Drying is not normally required for this material. If material has come into contact with moisture through improper storage or handling, drying may be necessary to prevent splay and odor problems.
Q10: What are recommended processing‑temperature windows?
A: Zone 1 temperature: 170-180°C; Zone 2 temperature: 180-190°C. Optimum mold temperature: 80-120°C.
Q11: What regions is this material available in?
A: Hostaform MT24U01 is available in North America, Europe, South and Central America, and Near East/Africa.
Q12: Is there a sustainable version available?
A: Yes, Hostaform MT24U01 ECO‑B is available as a sustainable version using a mass‑balance approach with biogenic feedstocks.
Q13: Can I buy this material and what is lead‑time?
A: Yes. Submit your inquiry via our quick inquiry form or email ruiqingchem@gmail.com, specify quantity, application and delivery address. Regular orders 1‑5 tons ship within 7‑10 working days after payment confirmation. Large‑volume or urgent orders can be negotiated separately.
Q14: What are limitations?
A: POM‑C does not resist strong mineral acids, powerful oxidizing agents, or continuous exposure to hot water >80°C. Consult our technical team for chemical‑compatibility data for your exact working environment.
CTA (Call to Action)
Ready to order Hostaform MT24U01?
To get precise quotation and professional technical support, please share these details:
-
Required quantity (kg or tons)
-
Destination port or delivery address
-
Target application and part brief (medical device, thin wall parts, fast cycling, etc.)
-
Core performance requirements (high flow, biocompatibility, sterilization method, etc.)
-
ECO‑B preference (standard or sustainable ECO‑B variant)
-
Document requirement (TDS, SDS, ISO 10993 report, USP Class VI certification, FDA compliance, etc.)
Sample Policy:
-
Samples are for laboratory validation tests only, not for mass‑production use.
-
Buyer bears international sample‑shipping freight.
-
If bulk‑material performance deviates from sample reference, Celanese official TDS serves as authoritative benchmark.
Take action now:
-
Send Inquiry – Use our quick inquiry form
-
Email Us –
ruiqingchem@gmail.com -
Live Chat – Click bottom‑right chat widget to speak directly with our team
After-Sales Support
| Service | Details |
|---|---|
| Quality Inspection Period | All quality‑related claims must be submitted within 7 working‑days after delivery, supported by test data and photographic evidence. |
| Return / Exchange Policy | Confirmed material defects caused by our side trigger replacement or refund. Terms and conditions apply. Please check our full Terms & Conditions. |
| Logistics Damage | Report shipping damage directly to carrier immediately upon goods receipt. We assist with claim‑document preparation. |
| Technical Support | Remote technical guidance available. On‑site molding troubleshooting service can be arranged upon special request. |
| Export Documentation | We supply standard export documents: commercial invoice, packing list, bill of lading, COA. Additional compliance certificates (e.g., ISO 10993 reports, USP Class VI certifications, FDA compliance documents) can be provided on request. |
Disclaimer
DISCLAIMER: All technical data is referenced from original Celanese typical values for Hostaform MT24U01. Our company acts as authorized distributor/trader rather than original manufacturer. Final component performance depends on part geometry, processing setup and end‑use environment. Buyers shall independently validate material suitability for individual applications, particularly for medical device applications where regulatory compliance and biocompatibility testing are required. Our firm bears no liability for finished‑part failure caused by improper design or improper processing. Always reference latest Celanese official TDS of Hostaform MT24U01 as definitive specification.


