描述
ULTEM Resin 1100F is a standard flow, unreinforced, amorphous polyetherimide (PEI) engineering thermoplastic manufactured by SABIC. As an authorized distributor and trader, we supply genuine SABIC materials with full traceability. For more product options and company information, please visit our website at https://szrqchem.com/.
ULTEM 1100F is a standard flow, unreinforced grade designed for injection molding applications. Key attributes include:
-
High Heat Resistance – Glass transition temperature (Tg) of 217°C ; RTI (Relative Thermal Index) of 170°C
-
Inherent Flame Retardancy – UL94 V-0 (0.75mm), V-2 (0.4mm) and 5VA (3.0mm) ratings without additives
-
Food Contact Approved – Complies with US FDA and EU Food Contact regulations
-
High Strength & Modulus – Tensile strength of 110 MPa; flexural modulus of 3,720 MPa
-
Excellent Dimensional Stability – Low mold shrinkage (0.50-0.70%)
-
ECO Conforming – Meets environmental compliance standards
-
Good Flow – Standard flow grade suitable for complex injection molded parts
Key Features of ULTEM 1100F
-
Standard Flow Grade – Designed for injection molding with good flow characteristics
-
High Heat Resistance – Glass transition temperature of 217°C; heat deflection temperature of 199°C at 1.8 MPa; RTI of 170°C
-
Inherent Flame Retardancy – UL94 V-0 (0.75mm) , V-2 (0.4mm) and 5VA (3.0mm) ratings; oxygen index of 47%
-
Food Contact Approved – Complies with US FDA and EU Food Contact regulations; suitable for food processing and food contact applications
-
High Mechanical Strength – Tensile strength of 110 MPa; flexural modulus of 3,720 MPa; Rockwell hardness M106
-
Excellent Dimensional Stability – Low mold shrinkage (0.50-0.70%); low creep and low warpage
-
Good Chemical Resistance – Resists automotive fluids, aircraft fluids, alcohols, acids, and weak aqueous solutions
-
Outstanding Electrical Properties – Excellent electrical insulation; arc resistance PLC 5
-
Low Smoke & Low Toxicity – Inherently low smoke and toxicity; suitable for aerospace and mass transit applications
-
ECO Conforming – Meets environmental compliance standards
Typical Applications for ULTEM 1100F
| Industry | Typical Applications |
|---|---|
| Food Processing | Food contact equipment, food processing components, FDA compliant parts |
| Aerospace | Aircraft interior components, panels, trim – FAR 25.853 compliant |
| Electrical & Electronics | High-temperature connectors, IC sockets, insulation parts, circuit boards, lighting |
| Automotive | Under-hood sensors, connectors, valves, transmission components, lamp reflectors |
| Semiconductor | High-temperature wafer carriers, sockets, and fluid handling components |
| Mass Transportation | Specialty vehicles, mass transportation components |
| Industrial | High-performance structural components, fasteners, and precision parts |
Typical Properties
| Property | ULTEM 1100F | Unit | Test Method |
|---|---|---|---|
| Density / Specific Gravity | 1.36 | g/cm³ | ASTM D792 |
| Melt Flow Rate (337°C/6.6kg) | 8.8 | g/10min | ASTM D1238 |
| Melt Volume Rate (MVR) | 12 | cm³/10min | ISO 1133 |
| Glass Transition Temperature (Tg) | 217 | °C | – |
| Heat Deflection Temp. (1.8MPa) | 199 | °C | ASTM D648 |
| RTI (Elec/Imp/Str) | 170 | °C | UL 746 |
| Tensile Strength (Yield) | 110 | MPa | ASTM D638 |
| Tensile Modulus | 3,720 | MPa | ASTM D638 |
| Flexural Strength | 165 | MPa | ASTM D790 |
| Flexural Modulus | 3,720 | MPa | ASTM D790 |
| Elongation at Break | 70 | % | ASTM D638 |
| Izod Impact (Notched, 23°C) | 37 | J/m | ASTM D256 |
| Unnotched Izod Impact | 1,500 | J/m | ASTM D256 |
| Rockwell Hardness | M106 | – | ASTM D785 |
| Mold Shrinkage (Flow) | 0.50-0.70 | % | SABIC Method |
| UL 94 Flammability | V-0 (0.75mm), V-2 (0.4mm), 5VA (3.0mm) | – | UL 94 |
| Oxygen Index (LOI) | 47 | % | ASTM D2863 |
Important Notes on Typical Data:
-
Values listed are typical and sourced from SABIC official data sheets. They do not constitute binding product specification.
-
Batch-to-batch deviations may exist. For critical applications, validate performance with batch-specific COA certificate.
-
Final performance depends on processing conditions, mold design, and part geometry.
-
SABIC official TDS shall serve as definitive technical reference. Request the latest official TDS from our sales team.
Processing Guidelines
| Parameter | Recommended Conditions |
|---|---|
| Drying | 150°C for 4-6 hours |
| Melt Temperature | 360-400°C |
| Mold Temperature | 140-180°C |
| Back Pressure | 0.3-0.7 MPa |
| Screw Speed | 40-70 rpm |
Critical Processing Warnings:
-
Drying: ULTEM 1100F is hygroscopic and must be dried to <0.02% moisture before processing. Dry at 150°C for 4-6 hours.
-
Melt Temperature: Recommended melt temperature range is 360-400°C. Avoid excessive residence times to prevent thermal degradation.
-
Mold Temperature: Higher mold temperatures (140-180°C) improve flow and reduce residual stress.
-
Not for Medical Applications: Effective June 2007, this grade is no longer supported with biocompatibility information and should not be used for medical applications which require biocompatibility. For medical applications, please use alternative grade HU1100.
-
Food Contact: Complies with US FDA and EU Food Contact regulations.
-
Gate Design: Use large gates and runners to minimize flow resistance and reduce molded-in stress.
Related Products
-
Explore PEI / Polyetherimide – Browse all ULTEM PEI resin options
-
Explore Engineering Plastics – Browse all engineering plastic materials
-
About Our Company – Learn more about our supply capabilities and quality assurance
Technical Documents
| Document Type | Description & Source |
|---|---|
| SABIC Official TDS | Complete physical, thermal, and mechanical properties of ULTEM 1100F |
| SABIC Official SDS | GHS-compliant chemical safety documentation |
| UL Yellow Card | UL certification E121562-101048254 |
| FDA Compliance Declaration | US FDA food contact compliance |
| EU Food Contact Compliance | EU Regulation (EU) 10/2011 compliance |
| COA (Certificate of Analysis) | Batch-specific quality certification |
| Processing Guide | Detailed processing guidelines for ULTEM resins |
Request any document above by:
-
Email:
ruiqingchem@gmail.com -
Online form: Our contact page
We reply within one working business day. Please clearly state product (ULTEM 1100F) and document type you require.
FAQ
Q1: What is ULTEM 1100F and what is it used for?
A: ULTEM 1100F is a standard flow, unreinforced polyetherimide (PEI) resin manufactured by SABIC. It combines high heat resistance (Tg 217°C), inherent flame retardancy (UL94 V-0), and food contact compliance (FDA & EU). It is widely used in food processing equipment, electrical/electronic components, automotive under-hood applications, aerospace interiors, and mass transportation.
Q2: Is ULTEM 1100F FDA compliant?
A: Yes. ULTEM 1100F complies with US FDA and EU Food Contact regulations.
Q3: What is the difference between ULTEM 1000 and ULTEM 1100F?
A: ULTEM 1100F offers food contact compliance (FDA & EU) and slightly higher flow compared to ULTEM 1000, making it suitable for applications requiring food contact approval. 1100F also has slightly higher density (1.36 vs 1.27 g/cm³).
Q4: What is the glass transition temperature of ULTEM 1100F?
A: The glass transition temperature (Tg) is 217°C.
Q5: What is the density of ULTEM 1100F?
A: The density is 1.36 g/cm³.
Q6: Is ULTEM 1100F flame retardant?
A: Yes. ULTEM 1100F is inherently flame retardant with UL94 V-0 (0.75mm), V-2 (0.4mm) and 5VA (3.0mm) ratings.
Q7: Can ULTEM 1100F be used for medical applications?
A: No. Effective June 2007, this grade is no longer supported with biocompatibility information and should not be used for medical applications which require biocompatibility. For medical applications, please use alternative grade HU1100.
Q8: What processing methods can be used for ULTEM 1100F?
A: ULTEM 1100F is primarily processed by injection molding.
Q9: What is the tensile strength of ULTEM 1100F?
A: Tensile strength is 110 MPa.
Q10: What is the lead time for orders?
A: Regular orders ship within 7-10 working days after payment confirmation. Large-volume or urgent orders can be negotiated separately.
CTA (Call to Action)
Ready to order ULTEM 1100F?
To get a precise quotation and professional technical support, please share:
-
Required quantity (kg)
-
Destination port or delivery address
-
Target application (food processing, aerospace, electrical, automotive, etc.)
-
Processing method (injection molding, etc.)
-
Color requirement (natural amber or custom color)
-
Document requirement (TDS, SDS, FDA compliance, COA, etc.)
Sample Policy:
-
Samples are for laboratory validation tests only, not for production use.
-
Buyer bears international sample-shipping freight.
-
If bulk-product performance deviates from sample reference, SABIC official TDS serves as the authoritative benchmark.
Take action now:
-
📧 Email Us –
ruiqingchem@gmail.com -
📝 Send Inquiry – Use our quick inquiry form
-
💬 Live Chat – Click the bottom-right chat widget to speak directly with our team
After-Sales Support
| Service | Details |
|---|---|
| Quality Inspection Period | All quality-related claims must be submitted within 7 working-days after delivery, supported by test data and photographic evidence. |
| Return / Exchange Policy | Confirmed product defects caused by our side trigger replacement or refund. Terms and conditions apply. |
| Logistics Damage | Report shipping damage directly to carrier immediately upon goods receipt. We assist with claim-document preparation. |
| Technical Support | Remote technical guidance available. On-site troubleshooting can be arranged upon special request. |
| Export Documentation | We supply commercial invoice, packing list, bill of lading, COA, and additional compliance certificates (e.g., FDA, EU, UL, RoHS) on request. |
Disclaimer
DISCLAIMER: All technical data is referenced from original SABIC typical values for ULTEM 1100F. Our company acts as authorized distributor/trader rather than original manufacturer. Final performance depends on processing conditions, mold design, and part geometry. Buyers shall independently validate product suitability for individual applications. Our firm bears no liability for product failure caused by improper processing or improper usage. Always reference the latest SABIC official TDS of ULTEM 1100F as the definitive specification.