描述
3M Novec 7200 Engineered Fluid Higher Boiling Vapor Degreasing
Chemistry: Ethoxy-nonafluorobutane
Boiling Point: 76°C
GWP: 55
NVR: 1.0 ppm max
Packing: 5 kg / 20 kg drum
3M Novec 7200 Engineered Fluid is a clear, colorless, low-odor fluid based on ethoxy-nonafluorobutane (C₄F₉OC₂H₅). With a higher boiling point of 76°C compared to Novec 7100 (61°C), it reduces evaporative losses, making it ideal for vapor degreasing, cold cleaning, and specialty solvent applications. This proprietary fluid offers zero ozone depletion potential and an exceptionally low GWP of 55, with an atmospheric lifetime of less than one year. Its low surface tension (13.6 dynes/cm) and low viscosity (0.61 cP) ensure excellent wetting and penetration for effective cleaning of complex geometries.
Novec 7200 provides a unique combination of properties: high purity (99.0% min) with non-volatile residue (NVR) as low as 1.0 ppm maximum, making it suitable for precision cleaning of sensitive electronic components. Its chemical and thermal stability, nonflammability (no flash point), and low toxicity (exposure guideline 200 ppm) make it a safe and sustainable replacement for CFCs, HCFCs, HFCs, and chlorinated solvents. Applications include vapor degreasing, cold cleaning, lubricant carrier for fluorocarbons/hydrocarbons/silicones, specialty solvents, dispersion media, reaction media, extraction solvents, and heat transfer fluids.
Genuine 3M Imported Stock and Technical Support
We supply stable spot inventory of genuine 3M Novec 7200 engineered fluid. Official TDS, SDS, and batch COA documents are available for vapor degreasing, cold cleaning, and precision cleaning applications.
Request Novec 7200 Quotation, TDS, SDS, and Sample
Complete SDS, COA, and technical documentation available
Core Advantages of 3M Novec 7200 Engineered Fluid
- Higher boiling point: 76°C — reduced evaporative losses for vapor degreasing and cold cleaning
- Ultra-low GWP: 55 — among the lowest global warming potential of any cleaning solvent
- Short atmospheric lifetime: 0.77 years — rapid degradation in the environment
- High purity: NVR ≤1.0 ppm — suitable for sensitive electronics and precision cleaning
- Zero ozone depletion potential — environmentally sustainable alternative
- Low surface tension: 13.6 dynes/cm — excellent wetting and penetration
- Nonflammable — no flash point, safe for industrial use
- Broad material compatibility — compatible with most metals, plastics, and elastomers
Main Applications
- Vapor degreasing — effective cleaning of metal, plastic, and glass components
- Cold cleaning — wipe solvent for flex circuits and sensitive assemblies
- Light-duty cleaning — removal of particulates, fluorolubes, light oils, and fluoropolymers
- Lubricant carrier — deposition of fluorocarbon, hydrocarbon, and silicone lubricants
- Specialty solvents — dispersion medium, reaction medium, extraction solvent
- Spray contact cleaner — replacement for CFC, HCFC, HFC, and PFC cleaners
- Heat transfer fluid — thermal management in electronic and industrial applications
Full Technical Parameters
| Property | Typical Value | Test Method |
| Chemical Name | Ethoxy-nonafluorobutane (C₄F₉OC₂H₅) | — |
| Appearance | Clear colorless liquid | Visual |
| Purity | 99.0% minimum | — |
| Non-Volatile Residue (NVR) | 1.0 ppm maximum | — |
| Molecular Weight | 264 | — |
| Boiling Point | 76°C | ASTM D1078 |
| Freeze Point | -138°C | ASTM D97 |
| Liquid Density (25°C) | 1.43 g/ml | ASTM D891 |
| Surface Tension | 13.6 dynes/cm | — |
| Vapor Pressure (25°C) | 109 mmHg | — |
| Viscosity (25°C) | 0.61 cP | — |
| Solubility in Water | <20 ppmw | — |
| Water Solubility | 92 ppmw | — |
| Heat of Vaporization | 30 cal/g | — |
| Specific Heat | 0.29 cal/g°C | — |
| Ozone Depletion Potential | 0.00 | — |
| Global Warming Potential | 55 | — |
| Atmospheric Lifetime | 0.77 years | — |
| Flash Point | None | — |
| Flammability Range in Air | 2.4 – 12.4% | ASTM E681-94 |
| Exposure Guideline (8hr TWA) | 200 ppm | 3M Medical Dept. |
| Acute Toxicity (4h LC50 Rat) | >92,000 ppm | — |
Note: All listed figures are typical values and may vary by production batch. Complete independent qualification testing is required before mass production deployment.
Handling and Storage Recommendations
| Storage Rules | Store sealed original containers in a dry, well-ventilated area away from heat sources and direct sunlight. |
| Forbidden Environments | Avoid exposure to open flames, strong oxidizing agents, and reactive metal powders. |
| Operation Protection | Maintain adequate ventilation. Wear nitrile protective gloves and anti-splash safety goggles during handling. |
Official Technical Documentation
| Document Type | Document Introduction | Document Request |
| TDS | 3M Novec 7200 original factory technical data sheet | Request TDS |
| SDS | Safety data sheet covering transport, storage, and handling guidelines | Request SDS |
| COA | Batch-specific certificate of analysis with purity and NVR specifications | Request COA |
Frequently Asked Questions
What is the boiling point of Novec 7200?
Novec 7200 has a boiling point of 76°C, which is higher than Novec 7100 (61°C), reducing evaporative losses and making it ideal for vapor degreasing and cold cleaning applications.
What is the GWP of Novec 7200?
Novec 7200 has an exceptionally low GWP of 55 (100-year ITH), one of the lowest among fluorinated solvents, with an atmospheric lifetime of only 0.77 years.
Is Novec 7200 flammable?
Novec 7200 is nonflammable under normal operating and storage conditions, with no flash point. It does have flammability limits of 2.4-12.4% by volume in air, similar to materials like HCFC-141b.
What is the purity and NVR of Novec 7200?
Novec 7200 has a minimum purity of 99.0% and a non-volatile residue (NVR) specification of 1.0 ppm maximum, making it suitable for precision cleaning and sensitive electronics applications.
What applications is Novec 7200 suitable for?
Novec 7200 is ideal for vapor degreasing, cold cleaning, light-duty cleaning of particulates and oils, lubricant carrier for fluorocarbons/hydrocarbons/silicones, specialty solvents, reaction media, and heat transfer fluids.
What is the exposure guideline for Novec 7200?
Novec 7200 has an 8-hour time-weighted average exposure guideline of 200 ppm, established by the 3M Medical Department, with a 4-hour rat LC50 of >92,000 ppm.
Related 3M Novec Engineered Fluids
Compare 3M Novec engineered fluids for different cleaning and application requirements.
| Product Grade | Boiling Point | GWP | NVR | Exposure Guideline | Core Application |
| Novec 7200 | 76°C | 55 | 1.0 ppm | 200 ppm | Vapor degreasing, cold cleaning |
| Novec 7100 | 61°C | 320 | 2.0 ppm | 750 ppm | Solvent cleaning, heat transfer |
| Novec 7000 | 34°C | 370 | 25 ppm | 75 ppm | Ultra-low temperature heat transfer |
Get 3M Novec 7200 Bulk Pricing and Technical Support
We supply genuine 3M Novec 7200 engineered fluid for vapor degreasing, cold cleaning, and specialty solvent applications. Contact us for bulk pricing, sample availability, technical documents, and application support.
Request Novec 7200 Technical Details
Disclaimer: All technical data on this page are for general guidance only and are not product specifications. Buyers must carry out independent trials and verify suitability before bulk ordering. Actual values may vary between production lots.