描述
NORYL N190 Resin is a non-reinforced, heat stabilized and impact modified blend of polyphenylene ether (PPE) and high impact polystyrene (HIPS), manufactured by SABIC. This injection moldable grade contains non-brominated, non-chlorinated flame retardant and carries a UL94 flame rating of 5VA at 3mm and V-0 at 1.5mm, along with a UL746C Outdoor Suitability rating of F1.
NORYL N190 Resin exhibits high impact strength, dimensional stability, low warpage, hydrolytic stability, and very low moisture absorption. This material is an excellent candidate for a variety of applications such as solar frames, unattended power supply (UPS) inverter/charger, indoor and outdoor electrical enclosures/housings/connectors, and wall plates/sockets/switches. This grade is also referred to as NORYL N1900 in several regions. Physical property data is determined using test methods established by ASTM International and ISO, the globally recognized standards organizations.
For more NORYL grades and technical information, please visit our PPO/PPE product page.
Key Features of NORYL N190 Resin
-
Halogen-Free Flame Retardant – Non-brominated, non-chlorinated flame retardant system
-
UL94 5VA & V-0 Rated – 5VA at 3mm; V-0 at 1.5mm
-
UL746C F1 Outdoor Suitability – Suitable for outdoor exposure with UV and weather resistance
-
High Impact Strength – Notched Izod impact of 283 J/m (ASTM D256)
-
Dimensional Stability – Precise part geometry with low warpage
-
Low Warpage – Minimizes deformation during processing and use
-
Hydrolytic Stability – Resists degradation in wet environments
-
Very Low Moisture Absorption – 0.07% water absorption (23°C/24hrs)
-
Heat Stabilized – Maintains properties under thermal exposure
-
Impact Modified – Enhanced impact resistance for demanding applications
-
Non-Reinforced PPE/HIPS Blend – Unfilled formulation for balanced performance
-
Injection Moldable – Suitable for standard injection molding processes
-
RoHS Compliant – Meets global environmental standards
Typical Applications for NORYL N190 Resin
| Industry | Typical Components & Considerations |
|---|---|
| Renewable Energy | Solar frames – UL746C F1 outdoor rating, weatherability, dimensional stability |
| Power Systems | Unattended power supply (UPS) inverter/charger – flame retardant, heat resistance |
| Electrical & Electronics | Indoor and outdoor electrical enclosures, housings, connectors – UL94 5VA/V-0, UL746C F1 |
| Building & Construction | Wall plates, sockets, switches – flame retardant, dimensional stability, low warpage |
| Drones | Drone structural components – lightweight, flame retardant, impact resistance |
Typical Properties of NORYL N190 Resin
| Property | Value | Test Method |
|---|---|---|
| Physical | ||
| Density / Specific Gravity | 1.08 g/cm³ (1080 kg/m³) | ASTM D792 / ISO 1183 |
| Water Absorption (23°C/24hrs) | 0.07% | ASTM D570 |
| Water Absorption (Saturated, 23°C) | 0.32% | ISO 62-1 |
| Moisture Absorption (23°C/50% RH) | 0.06% | ISO 62 |
| Mold Shrinkage, Flow (3.2mm) | 0.5 – 0.7% | SABIC Method |
| Melt Flow Rate (250°C/10.0kg) | 29.8 g/10min | ASTM D1238 |
| Melt Volume Rate (280°C/2.16kg) | 8 cm³/10min | ISO 1133 |
| Mechanical (ASTM) | ||
| Flexural Modulus | 2260 MPa | ASTM D790 |
| Flexural Strength | 68 MPa | ASTM D790 |
| Notched Izod Impact (1/8 in) | 283 J/m | ASTM D256 |
| Mechanical (ISO) | ||
| Tensile Modulus (1 mm/min) | 2300 MPa | ISO 527 |
| Tensile Stress, Yield (50 mm/min) | 50 MPa | ISO 527 |
| Tensile Stress, Break (50 mm/min) | 40 MPa | ISO 527 |
| Tensile Strain, Yield (50 mm/min) | 3% | ISO 527 |
| Tensile Strain, Break (50 mm/min) | 20% | ISO 527 |
| Flexural Modulus (2 mm/min) | 2200 MPa | ISO 178 |
| Flexural Yield Strength (2 mm/min) | 75 MPa | ISO 178 |
| Ball Indentation Hardness (H358/30) | 87 MPa | ISO 2039-1 |
| Thermal | ||
| HDT, 1.82 MPa (6.4mm, unannealed) | 90°C | ASTM D648 |
| CTE (-30°C to 30°C) | 7.1E-05 1/°C | TMA |
| Flammability | ||
| Flame Rating (3.0mm) | 5VA | UL 94 |
| Flame Rating (1.5mm) | V-0 | UL 94 |
| UL746C Outdoor Suitability | F1 | UL 746C |
| UL Yellow Card | E45587-237048 | UL |
Important Notes on Typical Data:
Values listed are typical and sourced from manufacturer data sheets. They do not constitute binding product specification.
Batch-to-batch deviations may exist. For critical applications, validate performance with batch-specific COA certificate.
Final performance depends on processing conditions and part design.
Manufacturer official TDS shall serve as definitive technical reference. Request the latest official TDS from our sales team.
Processing Guidelines for NORYL N190 Resin
| Step | Process |
|---|---|
| Drying Temperature | 80 – 100°C |
| Drying Time | Refer to full TDS |
| Hopper Temperature | 60 – 80°C |
| Front Zone 3 Temperature | 260 – 280°C |
| Melt Temperature | Refer to full TDS |
| Mold Temperature | Refer to full TDS |
| Process | Injection Molding |
| Storage | Store in original, sealed packaging in a cool, dry place away from direct sunlight |
Critical Processing Warnings:
Injection Molding: NORYL N190 is specifically designed for injection molding.
Drying: Proper drying is critical to prevent hydrolysis and achieve optimal mechanical properties. Dry at 80–100°C.
UL746C F1 Rating: This grade is UL746C F1 rated for outdoor suitability. Ensure processing conditions maintain compliance.
Storage: Store in original, sealed packaging in a cool, dry place away from direct sunlight.
Related Products
Explore Engineering Plastics – Browse all engineering plastic materials
About Our Company – Learn more about our supply capabilities and quality assurance
Technical Documents for NORYL N190 Resin
| Document Type | Description & Source |
|---|---|
| Manufacturer Official TDS | Complete physical, thermal, and mechanical properties of NORYL N190 |
| Manufacturer Official SDS | GHS-compliant safety documentation |
| COA (Certificate of Analysis) | Batch-specific quality certification |
| UL Yellow Card | E45587-237048 – UL safety certification |
Request any document above by:
Email: ruiqingchem@gmail.com
Online form: Our contact page
We reply within one working business day. Please clearly state product (NORYL N190) and document type you require.
FAQ about NORYL N190 Resin
Q1: What is NORYL N190?
A: NORYL N190 is a non-reinforced, heat stabilized and impact modified blend of polyphenylene ether (PPE) and high impact polystyrene (HIPS) from SABIC. It is an injection moldable grade with non-halogenated flame retardancy, UL94 5VA and V-0 ratings, UL746C F1 outdoor suitability, high impact strength, dimensional stability, low warpage, hydrolytic stability, and very low moisture absorption.
Q2: What are the key features of NORYL N190?
A: It offers halogen-free flame retardancy (UL94 5VA at 3mm & V-0 at 1.5mm), UL746C F1 outdoor rating, high impact strength (283 J/m notched Izod), dimensional stability, low warpage, hydrolytic stability, very low moisture absorption (0.07%), and heat stabilization.
Q3: What are the typical applications for NORYL N190?
A: Typical applications include solar frames, unattended power supply (UPS) inverter/charger, indoor and outdoor electrical enclosures/housings/connectors, wall plates/sockets/switches, and drone components.
Q4: What are the flame ratings of NORYL N190?
A: UL94 5VA at 3.0mm thickness and V-0 at 1.5mm thickness.
Q5: Is NORYL N190 suitable for outdoor use?
A: Yes, NORYL N190 carries a UL746C outdoor suitability rating of F1.
Q6: Is NORYL N190 halogen-free?
A: Yes, it contains non-brominated, non-chlorinated flame retardant.
Q7: What is the recommended processing method for NORYL N190?
A: NORYL N190 is designed for injection molding.
Q8: What is the recommended drying condition for NORYL N190?
A: Dry at 80–100°C for the appropriate time prior to processing.
Q9: What is the front zone temperature for NORYL N190?
A: The recommended front zone temperature is 260 – 280°C.
Q10: What is the UL Yellow Card number for NORYL N190?
A: E45587-237048.
Q11: What regions is NORYL N190 available in?
A: Asia Pacific and Europe.
Q12: What is the lead time for orders?
A: Regular orders ship within 7-10 working days after payment confirmation. Large-volume orders can be negotiated separately.
CTA (Call to Action)
Ready to order NORYL N190?
To get a precise quotation and professional technical support, please share:
-
Required quantity (kg)
-
Destination port or delivery address
-
Target application (solar frames, UPS, electrical enclosures, wall plates, etc.)
-
Document requirement (TDS, SDS, COA, UL docs, etc.)
Sample Policy:
-
Samples are for laboratory validation tests only, not for production use.
-
Buyer bears international sample-shipping freight.
-
If bulk-product performance deviates from sample reference, manufacturer official TDS serves as the authoritative benchmark.
Take action now:
-
📧 Email Us – ruiqingchem@gmail.com
-
📝 Send Inquiry – Use our quick inquiry form
-
💬 Live Chat – Click the bottom-right chat widget to speak directly with our team
After-Sales Support
| Service | Details |
|---|---|
| Quality Inspection Period | All quality-related claims must be submitted within 7 working days after delivery, supported by test data and photographic evidence. |
| Return / Exchange Policy | Confirmed product defects caused by our side trigger replacement or refund. Terms and conditions apply. |
| Logistics Damage | Report shipping damage directly to carrier immediately upon goods receipt. We assist with claim-document preparation. |
| Technical Support | Remote technical guidance available. On-site troubleshooting can be arranged upon special request. |
| Export Documentation | We supply commercial invoice, packing list, bill of lading, COA, and additional compliance certificates on request. |
Disclaimer
DISCLAIMER: All technical data is referenced from original manufacturer typical values for NORYL N190. Our company acts as authorized distributor/trader rather than original manufacturer. Final performance depends on processing conditions and part design. Buyers shall independently validate product suitability for individual applications. Our firm bears no liability for product failure caused by improper processing or improper usage. Always reference the latest manufacturer official TDS of NORYL N190 as the definitive specification.