描述
NORYL HNA055 Resin is a non-reinforced blend of polyphenylene ether (PPE) and high impact polystyrene (HIPS), manufactured by SABIC. This injection moldable grade was specifically designed to withstand extended duty high heat autoclave sterilization exceeding 2,500 cycles.
NORYL HNA055 exhibits good chemical resistance to lipids and typical hospital cleansers. This grade is US FDA Food Contact approved, biocompatible (ISO10993 or USP Class VI) , and RoHS compliant. It is subject to SABIC’s Healthcare management of change and formulation lock. NORYL HNA055 may be an excellent candidate for applications requiring extended duty sterilization cycles. Physical property data is determined using test methods established by ASTM International and ISO, the globally recognized standards organizations.
For more NORYL grades and technical information, please visit our PPO/PPE product page.
Key Features of NORYL HNA055 Resin
-
Extended Duty Autoclavable – Designed to withstand >2500 cycles of high heat autoclave sterilization
-
US FDA Food Contact Approved – Compliant with FDA regulations for food contact applications
-
Biocompatible – ISO10993 and USP Class VI compliant for medical device applications
-
RoHS Compliant – Meets global environmental and hazardous substance regulations
-
Good Chemical Resistance – Resists lipids and typical hospital cleansers
-
Multiple Sterilization Options – Supports steam, radiation, gamma, ethylene oxide (EtO), and E-beam sterilization
-
Non-Reinforced PPE/HIPS Blend – Unfilled formulation for balanced performance
-
Good Dimensional Stability – Low warpage for precise part geometry
-
High Stiffness – Flexural modulus of 2490 MPa (ISO) / 2540 MPa (ASTM)
-
Good Impact Strength – Notched Izod impact of 293 J/m (ASTM)
-
Low Moisture Absorption – Maintains properties in humid environments
-
Healthcare Grade – Subject to SABIC Healthcare management of change and formulation lock
Typical Applications for NORYL HNA055 Resin
| Industry | Typical Components & Considerations |
|---|---|
| Medical Devices | Sterilization trays, dental trays – extended duty autoclave cycles, FDA approved, biocompatible |
| Healthcare | Surgical instrument handles – multiple sterilization options, chemical resistance |
| Laboratory | Animal cages – autoclavable, chemical resistance |
| Pharmaceutical | Pharmaceutical packaging – FDA approved, sterilizable |
| Dental | Dental instruments and trays – extended duty sterilization |
Typical Properties of NORYL HNA055 Resin
| Property | Value | Test Method |
|---|---|---|
| Physical | ||
| Specific Gravity | 1.08 g/cm³ | ASTM D792 |
| Density | 1.08 g/cm³ | ISO 1183 |
| Linear Mold Shrinkage, Flow (3.2mm) | 0.6 – 0.8% | SABIC Method |
| Melt Flow Index (MFI) (300°C/5.0kg) | 6.2 g/10min | ASTM D1238 |
| Melt Volume Rate (MVR) (300°C/5.0kg) | 5 cm³/10min | ISO 1133 |
| Mechanical (ASTM) | ||
| Tensile Modulus | 2480 MPa | ASTM D638 |
| Tensile Strength at Yield | 67 MPa | ASTM D638 |
| Tensile Strength at Break | 55 MPa | ASTM D638 |
| Elongation at Yield | 4.8% | ASTM D638 |
| Elongation at Break | 16.3% | ASTM D638 |
| Flexural Modulus | 2540 MPa | ASTM D790 |
| Notched Izod Impact (1/8 in) | 293 J/m | ASTM D256 |
| Mechanical (ISO) | ||
| Tensile Modulus | 2400 MPa | ISO 527 |
| Tensile Stress at Yield | 67 MPa | ISO 527 |
| Tensile Stress at Break | 57 MPa | ISO 527 |
| Elongation at Break | 12.6% | ISO 527 |
| Flexural Modulus | 2490 MPa | ISO 178 |
| Charpy Notched Impact (23°C) | 27 kJ/m² | ISO 179/1eA |
| Notched Izod Impact (23°C, 4mm) | 24 kJ/m² | ISO 180/1A |
| Notched Izod Impact (-30°C, 4mm) | 14 kJ/m² | ISO 180/1A |
| Thermal | ||
| HDT, 1.82 MPa | Refer to full TDS | ASTM D648 / ISO 75 |
| Flammability | ||
| UL Rating | Non UL Rated | — |
Important Notes on Typical Data:
Values listed are typical and sourced from manufacturer data sheets. They do not constitute binding product specification.
Batch-to-batch deviations may exist. For critical applications, validate performance with batch-specific COA certificate.
Final performance depends on processing conditions and part design.
Manufacturer official TDS shall serve as definitive technical reference. Request the latest official TDS from our sales team.
Processing Guidelines for NORYL HNA055 Resin
| Step | Process |
|---|---|
| Processing Method | Injection molding |
| Drying | Refer to full TDS for specific drying conditions |
| Melt Temperature | Refer to full TDS |
| Mold Temperature | Refer to full TDS |
| Storage | Store in original, sealed packaging in a cool, dry place away from direct sunlight |
Critical Processing Warnings:
Injection Molding: NORYL HNA055 is specifically designed for injection molding.
Drying: Proper drying is critical to prevent hydrolysis and achieve optimal mechanical properties.
Sterilization Compatibility: This grade supports multiple sterilization methods including steam, radiation, gamma, ethylene oxide (EtO), and E-beam.
FDA & Biocompatibility Compliance: This grade is US FDA Food Contact approved and biocompatible (ISO10993 or USP Class VI). Ensure processing conditions maintain compliance.
UL Rating: NORYL HNA055 is Non UL Rated.
Storage: Store in original, sealed packaging in a cool, dry place away from direct sunlight.
Related Products
Explore Engineering Plastics – Browse all engineering plastic materials
About Our Company – Learn more about our supply capabilities and quality assurance
Technical Documents for NORYL HNA055 Resin
| Document Type | Description & Source |
|---|---|
| Manufacturer Official TDS | Complete physical, thermal, and mechanical properties of NORYL HNA055 |
| Manufacturer Official SDS | GHS-compliant safety documentation |
| COA (Certificate of Analysis) | Batch-specific quality certification |
| FDA Compliance Documentation | Food-contact compliance certificates |
| Biocompatibility Documentation | ISO10993 / USP Class VI certification |
Request any document above by:
Email: ruiqingchem@gmail.com
Online form: Our contact page
We reply within one working business day. Please clearly state product (NORYL HNA055) and document type you require.
FAQ about NORYL HNA055 Resin
Q1: What is NORYL HNA055?
A: NORYL HNA055 is a non-reinforced blend of polyphenylene ether (PPE) and high impact polystyrene (HIPS) from SABIC. It is an injection moldable grade designed to withstand extended duty high heat autoclave sterilization exceeding 2,500 cycles.
Q2: What are the key features of NORYL HNA055?
A: It offers extended duty autoclave resistance (>2500 cycles), US FDA Food Contact approval, biocompatibility (ISO10993 or USP Class VI), RoHS compliance, good chemical resistance to lipids and hospital cleansers, multiple sterilization options (steam, radiation, gamma, EtO, E-beam), good dimensional stability, and high stiffness.
Q3: What are the typical applications for NORYL HNA055?
A: Typical applications include sterilization trays, dental trays, surgical instrument handles, animal cages, and pharmaceutical packaging.
Q4: Is NORYL HNA055 FDA compliant?
A: Yes, NORYL HNA055 is US FDA Food Contact approved.
Q5: Is NORYL HNA055 biocompatible?
A: Yes, NORYL HNA055 is biocompatible per ISO10993 and USP Class VI standards.
Q6: Is NORYL HNA055 UL rated?
A: No, NORYL HNA055 is Non UL Rated.
Q7: What is the recommended processing method for NORYL HNA055?
A: NORYL HNA055 is designed for injection molding.
Q8: What is the specific gravity of NORYL HNA055?
A: The specific gravity is 1.08 g/cm³.
Q9: What is the tensile strength of NORYL HNA055?
A: Tensile strength at yield is 67 MPa and tensile strength at break is 55 MPa per ASTM D638.
Q10: What regions is NORYL HNA055 available in?
A: It is available in the Americas, Asia Pacific, and Europe.
Q11: What is the lead time for orders?
A: Regular orders ship within 7-10 working days after payment confirmation. Large-volume orders can be negotiated separately.
CTA (Call to Action)
Ready to order NORYL HNA055?
To get a precise quotation and professional technical support, please share:
-
Required quantity (kg)
-
Destination port or delivery address
-
Target application (sterilization trays, dental trays, surgical instruments, etc.)
-
Document requirement (TDS, SDS, COA, FDA/USP docs, etc.)
Sample Policy:
-
Samples are for laboratory validation tests only, not for production use.
-
Buyer bears international sample-shipping freight.
-
If bulk-product performance deviates from sample reference, manufacturer official TDS serves as the authoritative benchmark.
Take action now:
-
📧 Email Us – ruiqingchem@gmail.com
-
📝 Send Inquiry – Use our quick inquiry form
-
💬 Live Chat – Click the bottom-right chat widget to speak directly with our team
After-Sales Support
| Service | Details |
|---|---|
| Quality Inspection Period | All quality-related claims must be submitted within 7 working days after delivery, supported by test data and photographic evidence. |
| Return / Exchange Policy | Confirmed product defects caused by our side trigger replacement or refund. Terms and conditions apply. |
| Logistics Damage | Report shipping damage directly to carrier immediately upon goods receipt. We assist with claim-document preparation. |
| Technical Support | Remote technical guidance available. On-site troubleshooting can be arranged upon special request. |
| Export Documentation | We supply commercial invoice, packing list, bill of lading, COA, and additional compliance certificates on request. |
Disclaimer
DISCLAIMER: All technical data is referenced from original manufacturer typical values for NORYL HNA055. Our company acts as authorized distributor/trader rather than original manufacturer. Final performance depends on processing conditions and part design. Buyers shall independently validate product suitability for individual applications. Our firm bears no liability for product failure caused by improper processing or improper usage. Always reference the latest manufacturer official TDS of NORYL HNA055 as the definitive specification.