Fortron 6850L6 – 50% Mineral/Glass Reinforced PPS with Lowest Warpage for Thin-Wall Applications

基础信息

品名
Fortron 6850L6
牌号
6850L6
厂商
Celanese Corporation
材料类型
Unfilled Polyphenylene Sulfide (PPS)
产品形态
Pellets (Injection Molding Grade)
特点
Lowest warpage among Fortron grades; most isotropic grade; easy flow for thin-wall applications; 50% mineral/glass reinforcement; HDT 270°C; V-0 at 0.38mm; excellent dimensional stability; high hardness and rigidity

描述

Fortron 6850L6 is a 50% mineral and glass fiber reinforced polyphenylene sulfide (PPS) injection molding grade from Celanese Corporation. This grade offers the lowest warpage available among Fortron grades and is the most isotropic grade in the product line .

The easy flowing nature allows Fortron 6850L6 to be injection molded into thin-walled applications, particularly those with unfavorable flow length-to-wall thickness ratios . The excellent balance of mineral and glass fibers results in superior heat resistance and dimensional stability .

As a linear, semi-crystalline PPS, Fortron 6850L6 is relatively impermeable to gases, hydrocarbons, and other liquids compared to other materials . It provides low coefficient of friction, low shrinkage, excellent mechanical properties, creep resistance at high temperatures, a high continuous use temperature (160°C to 240°C), and very low moisture absorption .

This grade is inherently flame-retardant along with high hardness and rigidity . It offers high hardness, rigidity, and excellent resistance to corrosion, hydrolysis, oxidation, and paraffin buildup . It shows excellent chemical resistance to all solvents below 200°C, acids, bases, typical and alternative automotive fuels, and petroleum fluids at elevated temperatures . The material complies with RoHS, PFOS and PFOA regulations and is suitable for lead-free soldering and metal replacement applications .

For more PPS grades and technical information, please visit our PPS/Polyphenylene Sulfide product page. You can also explore Celanese’s official Fortron PPS portfolio for additional manufacturer insights.

Key Features of Fortron 6850L6

  • Lowest Warpage – Offers the lowest warpage among Fortron grades 

  • Most Isotropic Grade – The most isotropic grade in the Fortron series 

  • Easy Flow – Excellent flow for thin-walled applications with unfavorable flow length-to-wall thickness ratios 

  • 50% Mineral/Glass Reinforcement – Excellent balance of mineral and glass fibers for superior heat resistance and dimensional stability 

  • High Stiffness – Tensile modulus of 18,500 MPa ; flexural modulus of 16,800 MPa 

  • High Strength – Tensile strength of 125 MPa 

  • Excellent Heat Resistance – HDT of 270°C at 1.80 MPa ; melting temperature of 280°C 

  • Inherent Flame Retardancy – V-0 at 0.38mm and 1.5mm thickness 

  • Excellent Dimensional Stability – Low shrinkage: 0.3-0.6% parallel, 0.4-0.6% transverse 

  • Very Low Moisture Absorption – 0.02% water absorption 

  • Excellent Chemical Resistance – Resists solvents, acids, bases, and automotive fuels below 200°C 

  • Automotive Approved – Meets CONTINENTAL TST N 055 58.12 specification 

  • Regulatory Compliance – RoHS, PFOS, and PFOA compliant 

  • Global Supply – Available across North America, Europe, Asia Pacific, Latin America, Africa & Middle East 

Typical Applications for Fortron 6850L6

Industry Typical Components & Considerations
Thin-Wall Injection Molding Components with unfavorable flow length-to-wall thickness ratios – utilizing easy flow and lowest warpage 
Electronic Components Connectors, sensors, coil bobbins, SMT components – requiring V-0 flammability, low warpage, and dimensional stability
Automotive Under-the-hood components – meeting Continental specification 
Lead-Free Soldering Electronic components suitable for lead-free soldering processes 
Metal Replacement Applications requiring metal replacement with high-performance polymer 

Typical Properties of Fortron 6850L6

Property Value Test Method
Physical
Density 1.80 g/cm³ (1800 kg/m³) ISO 1183 
Water Absorption (Saturation) 0.02% ISO 62 
Molding Shrinkage – Parallel 0.3 – 0.6% ISO 294-4 
Molding Shrinkage – Transverse 0.4 – 0.6% ISO 294-4 
Mechanical
Tensile Modulus 18,500 MPa ISO 527 
Tensile Strength at Break 125 MPa ISO 527 
Tensile Strain at Break 1.0% ISO 527 
Flexural Modulus 16,800 MPa ISO 178 
Flexural Strength 190 MPa ISO 178 
Impact
Charpy Notched Impact (23°C) 4 kJ/m² ISO 179/1eA 
Charpy Unnotched Impact (23°C) 16 kJ/m² ISO 179/1eU 
Hardness, Rockwell M 96 ISO 2039-2 / ASTM D785 
Thermal
Melting Temperature 280°C ISO 11357 
Glass Transition Temperature 90°C ISO 11357 
HDT @ 1.80 MPa 270°C ISO 75 
HDT @ 8.00 MPa 215°C ISO 75 
CTE – Parallel 15 × 10⁻⁶/K ISO 11359 
CTE – Transverse 31 × 10⁻⁶/K ISO 11359 
Electrical
Volume Resistivity >1×10¹³ Ω·m IEC 62631 
Surface Resistivity >1×10¹⁵ Ω IEC 62631 
Dielectric Strength 25 kV/mm IEC 60243 
Flammability
Flammability @ 0.38mm V-0 UL 94 
Flammability @ 1.5mm V-0 UL 94 

Important Notes on Typical Data

📌 Values are typical – The data listed above is sourced from manufacturer data sheets for reference only and does not constitute binding product specifications for Fortron 6850L6.

📌 Batch variations – Batch-to-batch deviations may exist. For critical applications, validate performance with batch-specific COA certificates.

📌 Final performance – Actual performance depends on processing conditions and part design. Refer to ISO testing standards for detailed methodology.

📌 Authoritative reference – The manufacturer’s official TDS shall serve as the definitive technical reference for Fortron 6850L6. Request the latest official TDS from our sales team.

Processing Guidelines for Fortron 6850L6

Step Process
Processing Methods Injection Molding 
Drying Recommended Yes 
Drying Temperature 130 – 140°C 
Drying Time 3 – 4 hours
Suggested Max Moisture ≤ 0.02%
Dew Point Requirement ≤ -30°C 
Melt Temperature Range 330 – 340°C
Manifold / Hot Runner Temperature 330 – 340°C 
Mold Temperature 140 – 160°C 
Zone 1 Temperature 290 – 300°C
Zone 2 Temperature 310 – 320°C
Zone 3 Temperature 330 – 340°C
Zone 4 Temperature 330 – 340°C
Injection Pressure 50 – 100 MPa
Hold Pressure 30 – 70 MPa
Back Pressure ≤ 3 MPa
Screw Speed 0.2 – 0.3 m/s
Storage Store in original, sealed packaging in a cool, dry place away from direct sunlight

Critical Processing Warnings for Fortron 6850L6

⚠️ Drying Requirement – Fortron 6850L6 requires drying prior to processing. Because of the necessary low maximum residual moisture content, the use of dry air dryers is recommended. The dew point should be ≤ -30°C. The time between drying and processing should be as short as possible .

⚠️ Moisture Control – Maximum residual moisture content should be ≤ 0.02%. Proper drying is essential to prevent void formation and ensure optimal part quality.

⚠️ Melt Temperature – The recommended melt temperature range is 330–340°C. Avoid exceeding 340°C to prevent material degradation.

⚠️ Lowest Warpage / Most Isotropic – Fortron 6850L6 offers the lowest warpage and is the most isotropic grade available, making it ideal for thin-walled applications with unfavorable flow length-to-wall thickness ratios . Ensure proper part design to maximize these characteristics.

⚠️ Easy Flow Characteristics – This grade features easy flow for thin-walled applications. Adjust processing parameters accordingly to optimize fill and reduce pressure requirements .

⚠️ Storage – Store in original, sealed packaging in a cool, dry place away from direct sunlight. For subsequent storage, the material should be stored dry until processed.

Comparison: Fortron 6850L6 vs. Fortron 4665B6 vs. Fortron 6165A4

Feature Fortron 6850L6 Fortron 4665B6 Fortron 6165A4
Filler Content 50% Mineral/Glass 65% Mineral/Glass 65% Mineral/Glass
Key Feature Lowest warpage, Most isotropic, Easy flow High CTI (250), Very low warpage Highest stiffness, 5VA, Load bearing
Tensile Modulus 18,500 MPa 17,300 MPa 19,000 MPa
Tensile Strength 125 MPa 110-125 MPa 130 MPa
HDT @ 1.80 MPa 270°C 270°C 270°C
Flame Retardancy V-0 @ 0.38mm V-0 5VA @ 3.0mm
Density 1.80 g/cm³ 2.03 g/cm³ 1.95 g/cm³
Primary Application Thin-wall, lowest warpage applications High-voltage electronics, low warpage High-load structural components

Related Products

  • PPS/Polyphenylene Sulfide – View our full range of PPS products

  • Fortron 4665B6 – 65% mineral/glass reinforced PPS with high CTI (250)

  • Fortron 6165A4 – 65% mineral/glass reinforced PPS with highest stiffness and 5VA

  • Fortron 6162A7 – 60% mineral/glass reinforced PPS with high flow and CTI 225V

  • Explore Engineering Plastics – Browse all engineering plastic materials

  • About Our Company – Learn more about our supply capabilities and quality assurance

Technical Documents for Fortron 6850L6

Document Type Description & Source
Manufacturer Official TDS Complete physical, thermal, and mechanical properties of Fortron 6850L6
Manufacturer Official SDS GHS-compliant safety documentation
COA (Certificate of Analysis) Batch-specific quality certification for Fortron 6850L6
UL Yellow Card UL safety certification (E107854) 
Automotive Specification CONTINENTAL TST N 055 58.12 

Request any document above by:

📧 Email: ruiqingchem@gmail.com

📝 Online form: Our contact page

We reply within one working business day. Please clearly state product (Fortron 6850L6) and document type you require.

FAQ about Fortron 6850L6

Q1: What is Fortron 6850L6?
A: Fortron 6850L6 is a 50% mineral and glass fiber reinforced PPS injection molding grade from Celanese, offering the lowest warpage and the most isotropic properties in the Fortron series .

Q2: What are the key features of Fortron 6850L6?
A: Lowest warpage among Fortron grades; most isotropic grade; easy flow for thin-wall applications; tensile modulus 18,500 MPa; tensile strength 125 MPa; HDT 270°C; V-0 at 0.38mm; excellent chemical resistance; meets Continental specification .

Q3: What are the typical applications for Fortron 6850L6?
A: Thin-wall injection molded components with unfavorable flow length-to-wall thickness ratios, electronic components, automotive under-the-hood parts, lead-free soldering applications, and metal replacement applications .

Q4: What is the recommended drying condition for Fortron 6850L6?
A: Dry using a dehumidified air dryer with dew point ≤ -30°C. The time between drying and processing should be as short as possible . Maximum residual moisture should be ≤ 0.02%.

Q5: What is the density of Fortron 6850L6?
A: 1.80 g/cm³ (1800 kg/m³) .

Q6: What is the HDT @ 1.80 MPa of Fortron 6850L6?
A: 270°C .

Q7: What regions is Fortron 6850L6 available in?
A: North America, Europe, Asia Pacific, Latin America, Africa & Middle East .

Q8: Is Fortron 6850L6 flame retardant?
A: Yes, V-0 at 0.38mm and 1.5mm thickness (UL 94) .

Q9: What automotive specifications does Fortron 6850L6 meet?
A: CONTINENTAL TST N 055 58.12 .

Q10: Is Fortron 6850L6 the most isotropic grade?
A: Yes, it is the most isotropic grade in the Fortron series .

Q11: Is Fortron 6850L6 RoHS compliant?
A: Yes, it complies with RoHS, PFOS, and PFOA regulations .

Q12: What does “most isotropic” mean?
A: “Most isotropic” means the material exhibits the most balanced properties in all directions, minimizing directional variations in shrinkage and mechanical properties, which contributes to the lowest warpage.

Q13: What color options are available for Fortron 6850L6?
A: Black (SD3002 BLACK) is available .

CTA (Call to Action)

Ready to order Fortron 6850L6?

To get a precise quotation and professional technical support for Fortron 6850L6, please share:

  • Required quantity (kg)

  • Destination port or delivery address

  • Target application (thin-wall molding, electronic components, automotive, etc.)

  • Document requirements (TDS, SDS, COA, UL docs, Continental spec)

Sample Policy:

  • Samples of Fortron 6850L6 are for laboratory validation tests only, not for production use.

  • Buyer bears international sample-shipping freight.

  • If bulk-product performance deviates from sample reference, the manufacturer’s official TDS serves as the authoritative benchmark.

Take action now:

📧 Email Us – ruiqingchem@gmail.com

📝 Send Inquiry – Use our quick inquiry form

💬 Live Chat – Click the bottom-right chat widget to speak directly with our team

After-Sales Support

Service Details
Quality Inspection Period All quality-related claims must be submitted within 7 working days after delivery, supported by test data and photographic evidence.
Return / Exchange Policy Confirmed product defects caused by our side trigger replacement or refund. Terms and conditions apply.
Logistics Damage Report shipping damage directly to carrier immediately upon goods receipt. We assist with claim-document preparation.
Technical Support Remote technical guidance available. On-site troubleshooting can be arranged upon special request.
Export Documentation We supply commercial invoice, packing list, bill of lading, COA, and additional compliance certificates on request.

Disclaimer

DISCLAIMER: All technical data is referenced from original manufacturer typical values for Fortron 6850L6. Our company acts as supplier/trader rather than original manufacturer. Final performance depends on processing conditions and part design. Buyers shall independently validate product suitability for individual applications. Our firm bears no liability for product failure caused by improper processing or improper usage. Always reference the latest manufacturer official TDS of Fortron 6850L6 as the definitive specification.

Technical Documents

Download technical data sheets, safety data sheets and certificates for this material.

TDS Files

Technical document available for review or download.

0 Files
No TDS file uploaded yet.

MSDS Files

Technical document available for review or download.

0 Files
No MSDS file uploaded yet.