Fortron 1140L4 HR is a 40% glass fiber reinforced polyphenylene sulfide (PPS) injection molding grade from Celanese Corporation, featuring improved hydrolysis resistance. It is recognized as the strongest and toughest product available in the Fortron PPS portfolio .
The “HR” suffix designates Hydrolysis Resistance, making this grade particularly suitable for applications exposed to hot water, steam, or aggressive coolants—environments where standard PPS grades may experience performance degradation over time .
With 40% glass fiber reinforcement, Fortron 1140L4 HR delivers exceptional mechanical performance, including a tensile modulus of 15,600 MPa and tensile strength of 200 MPa . It exhibits outstanding heat resistance with a heat deflection temperature (HDT) of 270°C at 1.80 MPa, and excellent chemical resistance to acids, bases, and automotive fuels .
The high hardness and rigidity at elevated temperatures allows for good load bearing performance. This product has good weldability due to the modest filler level . Key applications include electronic components (bobbins, lamp housings, brush holders) and automotive parts requiring strength and resistance to aggressive chemicals (heaters, pumps, valves, fuel rails) .
For more PPS grades and technical information, please visit our PPS/Polyphenylene Sulfide product page. You can also explore Celanese’s official Fortron PPS portfolio for additional manufacturer insights.
Key Features of Fortron 1140L4 HR
-
40% Glass Fiber Reinforcement – Highest mechanical properties and stiffness
-
Improved Hydrolysis Resistance – “HR” designation for long-term performance in contact with hot water, steam, and coolants
-
Strongest & Toughest Grade – Unmatched mechanical performance in the Fortron PPS portfolio
-
High Strength – Tensile strength of 200 MPa; flexural strength of 290 MPa
-
High Stiffness – Tensile modulus of 15,600 MPa; flexural modulus of 14,600 MPa
-
Excellent Heat Resistance – HDT of 270°C at 1.80 MPa; continuous use up to 240°C
-
Inherent Flame Retardancy – V-0 at 0.38mm thickness; Oxygen Index 47%
-
Good Weldability – Modest filler level enables secondary welding operations
-
Excellent Chemical Resistance – Resists all solvents below 200°C, acids, bases, automotive fuels
-
Very Low Moisture Absorption – 0.02% water absorption
-
Regulatory Compliance – RoHS and REACH compliant
-
Global Supply – Available across North America, Europe, Asia Pacific, Latin America, Africa & Middle East
Typical Applications for Fortron 1140L4 HR
| Industry | Typical Components & Considerations |
|---|---|
| Automotive | Heaters (PTC heater housings), pumps (water pump impellers/housings), valves (thermostat/control valves), fuel rails – long-term contact with hot water, coolants, and aggressive chemicals |
| Electrical & Electronics | Bobbins, lamp housings, brush holders, connectors, sensors – requiring heat resistance and V-0 flammability |
| Appliances | Microwave oven rings, dishwasher components, water heater parts – requiring heat resistance and hot water contact |
| Industrial & Chemical | Distillation column packings, chemical pump components, valve bodies – requiring corrosion resistance |
Typical Properties of Fortron 1140L4 HR
| Property | Value | Test Method |
|---|---|---|
| Physical | ||
| Density | 1.66 – 1.70 g/cm³ | ISO 1183 |
| Water Absorption (Saturation) | 0.02% | ISO 62 |
| Molding Shrinkage – Parallel | 0.3% | ISO 294-4 |
| Molding Shrinkage – Transverse | 0.6% | ISO 294-4 |
| Mechanical | ||
| Tensile Modulus | 15,600 MPa | ISO 527 |
| Tensile Stress at Break | 200 MPa | ISO 527 |
| Tensile Strain at Break | 1.8% | ISO 527 |
| Flexural Modulus | 14,600 MPa | ISO 178 |
| Flexural Strength | 290 MPa | ISO 178 |
| Impact | ||
| Charpy Notched Impact (23°C) | 10 kJ/m² | ISO 179/1eA |
| Izod Notched Impact (23°C) | 8.5 kJ/m² | ISO 180/1A |
| Hardness, Rockwell M | 100 | ISO 2039-2 |
| Thermal | ||
| Melting Temperature | 280°C | ISO 11357 |
| Glass Transition Temperature | 90°C | ISO 11357 |
| HDT @ 1.80 MPa | 270°C | ISO 75 |
| Continuous Use Temperature | Up to 240°C | — |
| Thermal Conductivity, Flow | 0.47 W/(m·K) | ISO 22007-2 |
| Flammability | ||
| Flammability @ 0.38mm | V-0 | IEC 60695-11-10 |
| Oxygen Index | 47% | ISO 4589 |
Important Notes on Typical Data
📌 Values are typical – The data listed above is sourced from manufacturer data sheets for reference only and does not constitute binding product specifications for Fortron 1140L4 HR .
📌 Batch variations – Batch-to-batch deviations may exist. For critical applications, validate performance with batch-specific COA certificates.
📌 Final performance – Actual performance depends on processing conditions and part design. Refer to ISO testing standards for detailed methodology.
📌 Authoritative reference – The manufacturer’s official TDS shall serve as the definitive technical reference for Fortron 1140L4 HR. Request the latest official TDS from our sales team.
Processing Guidelines for Fortron 1140L4 HR
| Step | Process |
|---|---|
| Processing Methods | Injection Molding |
| Drying Recommended | Yes |
| Drying Temperature | 120 – 140°C |
| Drying Time | 3 – 4 hours |
| Suggested Max Moisture | ≤ 0.02% |
| Dew Point Requirement | ≤ -30°C |
| Melt Temperature | 330 – 340°C |
| Mold Temperature | 140 – 160°C |
| Hold Pressure | 30 – 70 MPa |
| Back Pressure | < 3.0 MPa |
| Storage | Store in original, sealed packaging in a cool, dry place away from direct sunlight |
Critical Processing Warnings for Fortron 1140L4 HR
⚠️ Drying Requirement – Fortron 1140L4 HR requires drying prior to processing. Dry at 120-140°C for 3-4 hours using a dehumidified air dryer with dew point ≤ -30°C . The time between drying and processing should be as short as possible.
⚠️ Moisture Control – Maximum residual moisture content should be ≤ 0.02% . Proper drying is essential to prevent void formation and ensure optimal part quality.
⚠️ Melt Temperature – The recommended melt temperature range is 330-340°C. Avoid exceeding 340°C to prevent material degradation .
⚠️ Reinforced Grade – Contains 40% glass fiber reinforcement, which may require consideration for equipment wear and proper screw design.
⚠️ Hydrolysis Resistance – The “HR” designation indicates improved resistance to hydrolysis, making this grade particularly suitable for long-term contact with hot water and coolants .
⚠️ Storage – Store in original, sealed packaging in a cool, dry place away from direct sunlight. For subsequent storage, the material should be stored dry until processed.
Comparison: Fortron 1140L4 HR vs. Fortron 1140L4 DW vs. Fortron 1140L0
| Feature | Fortron 1140L4 HR | Fortron 1140L4 DW | Fortron 1140L0 |
|---|---|---|---|
| Glass Fiber Content | 40% | 40% | 40% |
| Key Feature | Improved hydrolysis resistance | Drinking water approved | Extrusion grade |
| Primary Processing | Injection Molding | Injection Molding | Extrusion |
| Tensile Modulus | 15,600 MPa | 14,700 MPa | 7,600-12,000 MPa |
| Tensile Strength | 200 MPa | 195 MPa | 124-185 MPa |
| HDT @ 1.80 MPa | 270°C | 270°C | 240°C |
| Density | 1.66-1.70 g/cm³ | 1.66-1.70 g/cm³ | 1.65-1.66 g/cm³ |
| Special Feature | Hydrolysis resistance for coolants | Drinking water contact | Rod/slab/profile extrusion |
Related Products
-
PPS/Polyphenylene Sulfide – View our full range of PPS products
-
Fortron 1140L4 DW – 40% glass reinforced PPS for drinking water applications
-
Fortron 1140L0 – 40% glass reinforced PPS for extrusion (rods, slabs, profiles)
-
Fortron 1132L4 – 30% glass reinforced PPS for high-strength injection molding
-
Explore Engineering Plastics – Browse all engineering plastic materials
-
About Our Company – Learn more about our supply capabilities and quality assurance
Technical Documents for Fortron 1140L4 HR
| Document Type | Description & Source |
|---|---|
| Manufacturer Official TDS | Complete physical, thermal, and mechanical properties of Fortron 1140L4 HR |
| Manufacturer Official SDS | GHS-compliant safety documentation |
| COA (Certificate of Analysis) | Batch-specific quality certification for Fortron 1140L4 HR |
| UL Yellow Card | UL safety certification (UL94 V-0) |
Request any document above by:
📧 Email: ruiqingchem@gmail.com
📝 Online form: Our contact page
We reply within one working business day. Please clearly state product (Fortron 1140L4 HR) and document type you require.
FAQ about Fortron 1140L4 HR
Q1: What is Fortron 1140L4 HR?
A: Fortron 1140L4 HR is a 40% glass fiber reinforced PPS injection molding grade from Celanese with improved hydrolysis resistance, recognized as the strongest and toughest product in the Fortron PPS portfolio .
Q2: What does the “HR” suffix mean?
A: The “HR” suffix designates Hydrolysis Resistance, meaning this grade has enhanced resistance to degradation when in contact with hot water, steam, or aggressive coolants .
Q3: What are the key features of Fortron 1140L4 HR?
A: 40% glass reinforcement; improved hydrolysis resistance; strongest & toughest grade; tensile strength 200 MPa; HDT 270°C; V-0 at 0.38mm; excellent chemical resistance; good weldability .
Q4: What are the typical applications for Fortron 1140L4 HR?
A: Automotive heaters, pumps, valves, fuel rails; electronic components (bobbins, lamp housings, brush holders); microwave oven rings; distillation column packings .
Q5: What is the recommended drying condition for Fortron 1140L4 HR?
A: Dry at 120-140°C for 3-4 hours using a dehumidified air dryer with dew point ≤ -30°C. Maximum residual moisture ≤ 0.02% .
Q6: What is the density of Fortron 1140L4 HR?
A: 1.66 – 1.70 g/cm³ .
Q7: What is the HDT @ 1.80 MPa of Fortron 1140L4 HR?
A: 270°C .
Q8: What regions is Fortron 1140L4 HR available in?
A: North America, Europe, Asia Pacific, Latin America, Africa & Middle East .
Q9: Is Fortron 1140L4 HR flame retardant?
A: Yes. V-0 at 0.38mm thickness; Oxygen Index 47% .
Q10: What is the difference between Fortron 1140L4 HR and Fortron 1140L4 DW?
A: Both have 40% glass reinforcement and similar mechanical properties. Fortron 1140L4 HR is designed for improved hydrolysis resistance in contact with hot water and coolants, while Fortron 1140L4 DW is specifically developed for drinking water contact applications .
Q11: Is Fortron 1140L4 HR RoHS compliant?
A: Yes, it complies with RoHS regulations .
CTA (Call to Action)
Ready to order Fortron 1140L4 HR?
To get a precise quotation and professional technical support for Fortron 1140L4 HR, please share:
-
Required quantity (kg)
-
Destination port or delivery address
-
Target application (injection molding, automotive, electrical, etc.)
-
Document requirements (TDS, SDS, COA, UL docs)
Sample Policy:
-
Samples of Fortron 1140L4 HR are for laboratory validation tests only, not for production use.
-
Buyer bears international sample-shipping freight.
-
If bulk-product performance deviates from sample reference, the manufacturer’s official TDS serves as the authoritative benchmark.
Take action now:
📧 Email Us – ruiqingchem@gmail.com
📝 Send Inquiry – Use our quick inquiry form
💬 Live Chat – Click the bottom-right chat widget to speak directly with our team
After-Sales Support
| Service | Details |
|---|---|
| Quality Inspection Period | All quality-related claims must be submitted within 7 working days after delivery, supported by test data and photographic evidence. |
| Return / Exchange Policy | Confirmed product defects caused by our side trigger replacement or refund. Terms and conditions apply. |
| Logistics Damage | Report shipping damage directly to carrier immediately upon goods receipt. We assist with claim-document preparation. |
| Technical Support | Remote technical guidance available. On-site troubleshooting can be arranged upon special request. |
| Export Documentation | We supply commercial invoice, packing list, bill of lading, COA, and additional compliance certificates on request. |
Disclaimer
DISCLAIMER: All technical data is referenced from original manufacturer typical values for Fortron 1140L4 HR . Our company acts as supplier/trader rather than original manufacturer. Final performance depends on processing conditions and part design. Buyers shall independently validate product suitability for individual applications. Our firm bears no liability for product failure caused by improper processing or improper usage. Always reference the latest manufacturer official TDS of Fortron 1140L4 HR as the definitive specification.