描述
ULTEM Resin UF5011S is an enhanced flow, specialty filtered polyetherimide (PEI) resin manufactured by SABIC. As an authorized distributor and trader, we supply genuine SABIC materials with full traceability.
This unreinforced, amorphous grade is designed for applications requiring superior chemical resistance and high purity. It offers a glass transition temperature of 225°C, which is higher than standard PEI grades (typically 217°C), providing exceptional thermal stability in demanding environments.
ULTEM UF5011S is a specialty filtered grade – a unique trait among PEI resins – making it particularly suitable for applications where material purity is critical. The enhanced flow characteristics enable easier processing of complex geometries, while the enhanced chemical resistance to strong acids, bases, aromatics, and ketones expands its utility in aggressive chemical environments.
The material is ECO conforming, meeting environmental compliance standards. It is used across multiple industries including medical devices, automotive, electrical/electronic components, and general industrial applications. ISCC+ certified renewable bio-based solutions are also available for this grade.
Key Features
-
Enhanced Flow – Improved flow characteristics for easier processing and better mold filling of complex parts
-
Specialty Filtered – High purity grade suitable for applications requiring material cleanliness and consistency
-
High Heat Resistance – Glass transition temperature (Tg) of 225°C, higher than standard PEI (217°C)
-
Enhanced Chemical Resistance – Superior resistance to strong acids, bases, aromatics, and ketones
-
High Strength & Stiffness – Tensile modulus of 2,900 MPa; tensile yield strength of 100 MPa
-
Excellent Dimensional Stability – Low creep sensitivity and good dimensional stability
-
Good Impact Resistance – Notched Izod impact of 59 J/m (ASTM); unnotched Izod impact of 2,100 J/m
-
ECO Conforming – Meets environmental compliance standards
-
Medical Grade Potential – Suitable for medical device applications (surgical instruments, medical equipment housings) with appropriate certifications
-
Versatile Processing – Suitable for injection molding
Typical Applications
| Industry | Typical Components & Considerations |
|---|---|
| Medical Devices | Surgical instruments, medical device housings, sterilization containers – requires high purity and chemical resistance |
| Electrical & Electronics | Electrical components, connectors, housings – high heat resistance and insulation properties |
| Automotive | Under-hood components, sensors, connectors – heat and chemical resistance |
| Industrial | Material handling, chemical processing components – resistance to aggressive chemicals |
| Consumer Goods | Home appliances, personal accessories – durability and aesthetics |
Typical Properties
| Property | Typical Value | Unit | Test Method |
|---|---|---|---|
| Physical | |||
| Specific Gravity / Density | 1.28 | g/cm³ | ASTM D792 / ISO 1183 |
| MFR (337°C/6.6kg) | 11 | g/10min | ASTM D1238 |
| MVR (360°C/5kg) | 20 | cm³/10min | ISO 1133 |
| Mold Shrinkage, Flow (3.2mm) | 0.40 – 0.70 | % | SABIC Method |
| Water Absorption (Saturation, 23°C) | 1.2 | % | ISO 62-1 |
| Moisture Absorption (23°C/50% RH) | 0.20 | % | ISO 62 |
| Mechanical | |||
| Tensile Modulus | 2,900 | MPa | ASTM D638 / ISO 527 |
| Tensile Strength (Yield) | 100 | MPa | ASTM D638 / ISO 527 |
| Tensile Strength (Break) – ASTM | 75 | MPa | ASTM D638 |
| Tensile Strength (Break) – ISO | 85 | MPa | ISO 527 |
| Elongation at Yield | 8.0 | % | ASTM D638 / ISO 527 |
| Elongation at Break – ASTM | 60 | % | ASTM D638 |
| Elongation at Break – ISO | 50 | % | ISO 527 |
| Flexural Modulus – ASTM | 3,100 | MPa | ASTM D790 |
| Flexural Modulus – ISO | 2,900 | MPa | ISO 178 |
| Flexural Strength (Yield) – ASTM | 138 | MPa | ASTM D790 |
| Impact | |||
| Izod Impact (Notched, 23°C) – ASTM | 59 | J/m | ASTM D256 |
| Izod Impact (Notched, 23°C) – ISO | 5.0 | kJ/m² | ISO 180/1A |
| Izod Impact (Unnotched, 23°C) – ASTM | 2,100 | J/m | ASTM D4812 |
| Reverse Notch Izod Impact (3.2mm) | 2,100 | J/m | ASTM D256 |
| Charpy Impact (Notched, 23°C) | 7.0 | kJ/m² | ISO 179/1eA |
| Thermal | |||
| Glass Transition Temperature (Tg) | 225 | °C | |
| Heat Deflection Temp. (0.45 MPa, 3.2mm) | 213 | °C | ASTM D648 |
| Vicat Softening Temp. (A/50) | 220 | °C | ISO 306 |
| Vicat Softening Temp. (B/120) | 215 | °C | ISO 306 |
| Thermal Conductivity | 0.31 | W/m-°C | ASTM C177 |
Processing Guidelines
| Step | Process |
|---|---|
| Drying | 135-150°C for 4-6 hours (moisture <0.02%) |
| Front Zone 3 Temperature | 365 – 390°C |
| Back Pressure | 0.3 – 0.7 MPa |
| Vent Depth | 0.025 – 0.076 mm |
| Injection Molding | Standard injection molding equipment; enhanced flow enables complex geometries |
Critical Processing Warnings:
-
Drying: ULTEM UF5011S is hygroscopic and must be dried to <0.02% moisture before processing.
-
Enhanced Flow: This grade offers improved flow characteristics for easier processing and better mold filling of complex parts.
-
Specialty Filtered: The specialty filtered nature of this grade provides high purity; maintain clean processing conditions.
-
Melt Temperature: Recommended front zone temperature is 365-390°C. Avoid excessive residence times.
-
Medical Applications: For medical device applications, verify biocompatibility (ISO 10993/USP Class VI) certification for your specific end-use requirements.
Related Products
-
Explore PEI / Polyetherimide – Browse all ULTEM PEI resin options
-
Explore Engineering Plastics – Browse all engineering plastic materials
-
About Our Company – Learn more about our supply capabilities and quality assurance
Technical Documents
| Document Type | Description & Source |
|---|---|
| SABIC Official TDS | Complete physical, thermal, and mechanical properties of ULTEM UF5011S |
| SABIC Official SDS | GHS-compliant chemical safety documentation |
| ECO Certification | ECO conforming documentation |
| COA (Certificate of Analysis) | Batch-specific quality certification |
Request any document above by:
-
Email:
ruiqingchem@gmail.com -
Online form: Our contact page
We reply within one working business day. Please clearly state product (ULTEM UF5011S) and document type you require.
FAQ
Q1: What is ULTEM UF5011S?
A: ULTEM UF5011S is an enhanced flow, specialty filtered polyetherimide (PEI) resin manufactured by SABIC. It offers a glass transition temperature of 225°C, enhanced chemical resistance to strong acids, bases, aromatics, and ketones, and is ECO conforming. It is available in color UF5011S-1000.
Q2: What is the glass transition temperature of ULTEM UF5011S?
A: The glass transition temperature (Tg) is 225°C, which is higher than standard PEI grades (typically 217°C).
Q3: Is ULTEM UF5011S suitable for medical applications?
A: Yes. ULTEM UF5011S is used in medical device applications including surgical instruments and medical equipment housings. For specific medical applications, verify biocompatibility (ISO 10993/USP Class VI) certification for your end-use requirements.
Q4: What is the density of ULTEM UF5011S?
A: The density is 1.28 g/cm³ (ASTM D792 / ISO 1183).
Q5: What makes UF5011S “specialty filtered”?
A: The specialty filtered designation indicates a higher purity grade, making it particularly suitable for applications where material cleanliness and consistency are critical.
Q6: What is the chemical resistance of ULTEM UF5011S?
A: ULTEM UF5011S offers enhanced chemical resistance to strong acids, bases, aromatics, and ketones, making it suitable for aggressive chemical environments.
Q7: What is the melt flow rate of ULTEM UF5011S?
A: The Melt Flow Rate (MFR) is 11 g/10min at 337°C, 6.6kg (ASTM D1238); the Melt Volume Rate (MVR) is 20 cm³/10min at 360°C, 5kg (ISO 1133).
Q8: What is the tensile strength of ULTEM UF5011S?
A: Tensile yield strength is 100 MPa; tensile break strength is 75 MPa (ASTM) / 85 MPa (ISO).
Q9: Is ULTEM UF5011S ECO conforming?
A: Yes. ULTEM UF5011S is ECO conforming, meeting environmental compliance standards.
Q10: What processing methods can be used for ULTEM UF5011S?
A: ULTEM UF5011S is processed by injection molding. The enhanced flow enables easier processing of complex geometries.
Q11: What is the recommended drying condition for ULTEM UF5011S?
A: Dry at 135-150°C for 4-6 hours to <0.02% moisture.
Q12: What is the recommended front zone temperature for injection molding ULTEM UF5011S?
A: Recommended front zone temperature is 365-390°C.
Q13: What is the heat deflection temperature of ULTEM UF5011S?
A: Heat deflection temperature is 213°C at 0.45 MPa (3.2mm, unannealed).
Q14: What is the Vicat softening temperature of ULTEM UF5011S?
A: Vicat softening temperature is 220°C (A/50) and 215°C (B/120).
Q15: What is the lead time for orders?
A: Regular orders ship within 7-10 working days after payment confirmation. Large-volume or urgent orders can be negotiated separately.
CTA (Call to Action)
Ready to order ULTEM UF5011S?
To get a precise quotation and professional technical support, please share:
-
Required quantity (kg)
-
Destination port or delivery address
-
Target application (medical, electrical, automotive, industrial, etc.)
-
Color requirement (UF5011S-1000 or custom color)
-
Document requirement (TDS, SDS, ECO certification, COA, etc.)
Sample Policy:
-
Samples are for laboratory validation tests only, not for production use.
-
Buyer bears international sample-shipping freight.
-
If bulk-product performance deviates from sample reference, SABIC official TDS serves as the authoritative benchmark.
Take action now:
-
📧 Email Us –
ruiqingchem@gmail.com -
📝 Send Inquiry – Use our quick inquiry form
-
💬 Live Chat – Click the bottom-right chat widget to speak directly with our team
After-Sales Support
| Service | Details |
|---|---|
| Quality Inspection Period | All quality-related claims must be submitted within 7 working-days after delivery, supported by test data and photographic evidence. |
| Return / Exchange Policy | Confirmed product defects caused by our side trigger replacement or refund. Terms and conditions apply. |
| Logistics Damage | Report shipping damage directly to carrier immediately upon goods receipt. We assist with claim-document preparation. |
| Technical Support | Remote technical guidance available. On-site troubleshooting can be arranged upon special request. |
| Export Documentation | We supply commercial invoice, packing list, bill of lading, COA, and additional compliance certificates (e.g., ECO) on request. |
Disclaimer
DISCLAIMER: All technical data is referenced from original SABIC typical values for ULTEM UF5011S. Our company acts as authorized distributor/trader rather than original manufacturer. Final performance depends on processing conditions, mold design, and part geometry. Buyers shall independently validate product suitability for individual applications, particularly for medical device applications where regulatory compliance must be verified under end-use conditions. Our firm bears no liability for product failure caused by improper processing or improper usage. Always reference the latest SABIC official TDS of ULTEM UF5011S as the definitive specification.


