ULTEM Resin HU2110 is a 10% glass fiber reinforced, enhanced flow healthcare grade polyetherimide (PEI) resin manufactured by SABIC. As an authorized distributor and trader, we supply genuine SABIC materials with full traceability.
ULTEM HU2110 is specifically developed for medical devices and pharmaceutical applications. The 10% glass fiber reinforcement provides enhanced stiffness and dimensional stability while maintaining the excellent heat resistance and chemical resistance inherent to PEI. The enhanced flow characteristics enable easier processing of complex, thin-walled parts.
This grade is biocompatible per ISO 10993 or USP Class VI and supports multiple sterilization methods including steam, gamma irradiation, ethylene oxide (EtO), and E-beam. It is FDA and EU food contact compliant and ECO conforming.
With its inherent flame retardancy (UL94 V-0 and 5VA), high stiffness, enhanced flow, hydrolytic stability, and chemical resistance, ULTEM HU2110 is the trusted choice for demanding healthcare environments where performance, safety, and reliability are critical.
Key Features of ULTEM HU2110
-
10% Glass Fiber Reinforced – Provides enhanced stiffness, strength, and dimensional stability compared to unreinforced grades; tensile modulus of 4,610-9,500 MPa
-
Enhanced Flow – Improved flow characteristics (MFI 11.3 g/10min at 337°C/6.6kg) for easier processing and better mold filling of complex, thin-walled parts
-
Healthcare Grade – Specifically developed for medical devices and pharmaceutical applications; biocompatible (ISO 10993 or USP Class VI)
-
Multiple Sterilization Compatibility – Supports steam, gamma irradiation, ethylene oxide (EtO), and E-beam sterilization
-
High Heat Resistance – Glass transition temperature of 217°C; HDT of 205°C at 1.80 MPa; Vicat softening temperature of 220°C
-
Inherent Flame Retardancy – UL94 V-0 (0.2mm) and 5VA (1.9mm) ratings
-
High Stiffness & Strength – Tensile modulus of 4,610 MPa (ASTM) / 9,500 MPa (ISO); tensile yield strength of 114 MPa (ASTM) / 165 MPa (ISO)
-
Excellent Dimensional Stability – Low shrinkage (0.20-0.40%) and low creep sensitivity
-
Food Contact Compliant – FDA and EU food contact compliant
-
Good Chemical Resistance – Excellent resistance to automotive fluids, aircraft fluids, aliphatic hydrocarbons, alcohols, acids, and weak aqueous solutions
-
Hydrolytic Stability – Good resistance to moisture and hydrolysis
-
Low Smoke & Low Toxicity – Inherently low smoke and toxicity
-
Good Metal Adhesion – Suitable for applications requiring metal bonding
-
ECO Conforming – Meets environmental compliance standards
-
Versatile Processing – Suitable for injection molding
HU Series Healthcare Grade Comparison
| Property | HU1100 | HU1110 | HU2100 | HU2110 |
|---|---|---|---|---|
| Glass Fiber Content | 0% | 0% | 10% | 10% |
| Flow Type | Standard | Enhanced | Standard | Enhanced |
| MFR (337°C/6.6kg) | 8.8 g/10min | 16 g/10min | 7 g/10min | 11.3 g/10min |
| Tensile Modulus (ASTM) | 3,720 MPa | — | 4,680 MPa | 4,610 MPa |
| Yield Stress (ASTM) | 110 MPa | 110 MPa | 114 MPa | 114 MPa |
| HDT (1.80 MPa) | 188°C | 210°C | 205°C | 205°C |
| Shrinkage | 0.50-0.70% | — | 0.5-0.6% | 0.20-0.40% |
| Biocompatibility | ISO 10993 / USP Class VI | ISO 10993 / USP Class VI | ISO 10993 / USP Class VI | ISO 10993 / USP Class VI |
| Sterilization | Steam, Gamma, EtO, E-beam | Steam, Gamma, EtO, E-beam | Steam, Gamma, EtO, E-beam | Steam, Gamma, EtO, E-beam |
| Key Feature | Standard flow, unreinforced | Enhanced flow, unreinforced | 10% glass, standard flow | 10% glass, enhanced flow |
Typical Applications for ULTEM HU2110
| Industry | Typical Applications |
|---|---|
| Medical Devices | Surgical instruments, reusable medical devices – withstands multiple sterilization cycles |
| Pharmaceutical Packaging & Drug Delivery | Drug delivery systems, pharmaceutical packaging – biocompatible, FDA compliant |
| Sterilization Trays & Containers | Sterilization trays, containers – supports steam, gamma, EtO, and E-beam sterilization |
| Laboratory Ware & Clinical Diagnostics | Lab ware, clinical diagnostics equipment – chemically resistant, sterilizable |
| Medical Device Components | Enclosures, housings, covers – high strength, flame retardant, sterilizable |
| Healthcare Infrastructure | Healthcare facility infrastructure components – durable, sterilizable |
Typical Properties
| Property | HU2110 (ASTM) | HU2110 (ISO) | Unit | Test Method |
|---|---|---|---|---|
| Physical | ||||
| Density | 1.34 | 1.42 | g/cm³ | ASTM D792 / ISO 1183 |
| Melt Flow Rate (MFR) – 337°C/6.6kg | 11.3 | — | g/10min | ASTM D1238 |
| Mold Shrinkage, Flow (3.2mm) | 0.20 – 0.40 | — | % | Internal Method |
| Water Absorption (Saturation) | — | 0.90 | % | ISO 62 |
| Humidity Absorption (23°C/50% RH) | — | 0.50 | % | ISO 62 |
| Mechanical | ||||
| Tensile Modulus | 4,610 | 9,500 | MPa | ASTM D638 / ISO 527 |
| Tensile Strength (Yield) | 114 | 165 | MPa | ASTM D638 / ISO 527 |
| Tensile Strength (Break) | 116 | 165 | MPa | ASTM D638 / ISO 527 |
| Yield Strain | 3.0 | 2.0 | % | ASTM D638 / ISO 527 |
| Elongation at Break | 3.0 | 2.0 | % | ASTM D638 / ISO 527 |
| Flexural Modulus | 6,850 | 6,890 | MPa | ASTM D790 / ISO 178 |
| Flexural Strength (Yield) | 225 | 228 | MPa | ASTM D790 / ISO 178 |
| Impact | ||||
| Izod Impact (Notched, 23°C) | 48 | 64 | J/m / kJ/m² | ASTM D256 / ISO 180/1A |
| Izod Impact (Notched, -30°C) | 64 | 70 | J/m / kJ/m² | ASTM D256 / ISO 180/1A |
| Charpy Impact (Notched, 23°C) | — | 65 | kJ/m² | ISO 179/1eA |
| Instrumented Dart Impact (23°C, Total Energy) | 8.00 | — | J | ASTM D3763 |
| Thermal | ||||
| Glass Transition Temperature (Tg) | 217 | 217 | °C | |
| Heat Deflection Temp. (1.80 MPa) | 208 | 205 | °C | ASTM D648 / ISO 75-1/-2 |
| Vicat Softening Temp. (B50) | 220 | 220 | °C | ASTM D1525 / ISO 306 |
| Vicat Softening Temp. (120°C/h 50N) | — | 213 | °C | ISO 306 |
| CTE, Flow (-40 to 40°C) | 2.5×10⁻⁵ | 2.5×10⁻⁵ | cm/cm/°C | ASTM E831 / ISO 11359-2 |
| CTE, Transverse (-40 to 40°C) | 5.0×10⁻⁵ | 5.0×10⁻⁵ | cm/cm/°C | ASTM E831 / ISO 11359-2 |
| Flammability | ||||
| UL 94 Flammability | V-0 (0.2mm), 5VA (1.9mm) | — | — | UL 94 |
| Regulatory | ||||
| ECO Conforming | Yes | — | — | |
| Biocompatibility | ISO 10993 / USP Class VI | — | — | |
| Food Contact | FDA & EU compliant | — | — |
Important Notes on Typical Data:
-
Values listed are typical and sourced from SABIC official data sheets. They do not constitute binding product specification.
-
Batch-to-batch deviations may exist. For critical applications, validate performance with batch-specific COA certificate.
-
Final performance depends on processing conditions, mold design, and part geometry.
-
SABIC official TDS shall serve as definitive technical reference. Request the latest official TDS from our sales team.
Processing Guidelines (Injection MoldinG)
| Parameter | Recommended Conditions | |
|---|---|---|
| Drying | ||
| Drying Temperature | 150°C | |
| Drying Time | 4 – 6 hours | |
| Maximum Moisture Content | ≤0.02% | |
| Injection Molding | ||
| Processing (Melt) Temperature | 350 – 400°C | |
| Mold Temperature | 135 – 165°C | |
| Back Pressure | 0.3 – 0.7 MPa | |
| Screw Speed | 40 – 70 rpm | |
| Vent Depth | 0.025 – 0.076 mm |
Critical Processing Warnings:
-
Drying: ULTEM HU2110 is hygroscopic and must be dried to ≤0.02% moisture before processing. Dry at 150°C for 4-6 hours.
-
Enhanced Flow: This grade offers enhanced flow characteristics (MFI 11.3 g/10min) for easier processing and better mold filling of complex, thin-walled parts.
-
Melt Temperature: Recommended melt temperature range is 350-400°C. Avoid excessive residence times to prevent thermal degradation.
-
Mold Temperature: Higher mold temperatures (135-165°C) improve flow and reduce residual stress.
-
Healthcare Applications: This grade is specifically designed for medical devices and pharmaceutical applications. It is biocompatible (ISO 10993 or USP Class VI) and healthcare management of change applies.
-
Sterilization: ULTEM HU2110 supports steam, gamma, EtO, and E-beam sterilization. Verify compatibility with your specific sterilization protocol.
-
Food Contact: This material is food contact compliant in most jurisdictions – exceptions may exist, request a declaration for details.
-
PFAS-Free: This product does not contain PFAS intentionally added during manufacturing.
-
Gate Design: Use large gates and runners to minimize flow resistance and reduce molded-in stress.
-
Regrind: Regrind can be used up to 20-25% with virgin material, provided it is clean and properly dried.
Related Products
-
Explore PEI / Polyetherimide – Browse all ULTEM PEI resin options
-
Explore Engineering Plastics – Browse all engineering plastic materials
-
ULTEM HU2100 – Healthcare Grade PEI – 10% glass fiber reinforced, standard flow
-
ULTEM HU1110 – Healthcare Grade PEI – Enhanced flow, unreinforced
-
About Our Company – Learn more about our supply capabilities and quality assurance
Technical Documents
| Document Type | Description & Source |
|---|---|
| SABIC Official TDS | Complete physical, thermal, and mechanical properties of ULTEM HU2110 |
| SABIC Official SDS | GHS-compliant chemical safety documentation |
| UL Yellow Card | UL certification E121562-101082080 |
| ISO 10993 / USP Class VI | Biocompatibility certification |
| FDA Compliance Declaration | FDA food contact compliance |
| EU Food Contact Compliance | European food contact compliance |
| COA (Certificate of Analysis) | Batch-specific quality certification |
| Processing Guide | Detailed processing guidelines for ULTEM HU2110 |
Request any document above by:
-
Email:
ruiqingchem@gmail.com -
Online form: Our contact page
We reply within one working business day. Please clearly state product (ULTEM HU2110) and document type you require.
FAQ
Q1: What is ULTEM HU2110 and what is it used for?
A: ULTEM HU2110 is a 10% glass fiber reinforced, enhanced flow healthcare grade polyetherimide (PEI) resin manufactured by SABIC. It is specifically developed for medical devices and pharmaceutical applications. It is widely used in surgical instruments, pharmaceutical packaging, drug delivery systems, sterilization trays, laboratory ware, and general healthcare equipment.
Q2: Is ULTEM HU2110 biocompatible?
A: Yes. ULTEM HU2110 is biocompatible per ISO 10993 or USP Class VI, making it suitable for regulated medical and pharmaceutical applications.
Q3: Is ULTEM HU2110 FDA compliant?
A: Yes. ULTEM HU2110 is FDA and EU food contact compliant. It is food contact compliant in most jurisdictions – exceptions may exist, request a declaration for details.
Q4: What sterilization methods can ULTEM HU2110 withstand?
A: ULTEM HU2110 supports steam sterilization, gamma irradiation, ethylene oxide (EtO), and E-beam sterilization.
Q5: What is the glass transition temperature of ULTEM HU2110?
A: The glass transition temperature (Tg) is 217°C.
Q6: What is the density of ULTEM HU2110?
A: Density is 1.34 g/cm³ (ASTM D792) and 1.42 g/cm³ (ISO 1183).
Q7: Is ULTEM HU2110 flame retardant?
A: Yes. ULTEM HU2110 is inherently flame retardant with UL94 V-0 (0.2mm) and 5VA (1.9mm) ratings.
Q8: What is the glass fiber content of ULTEM HU2110?
A: ULTEM HU2110 contains 10% glass fiber reinforcement.
Q9: What is the melt flow rate of ULTEM HU2110?
A: The Melt Flow Rate (MFR) is 11.3 g/10min at 337°C, 6.6kg.
Q10: What is the tensile strength of ULTEM HU2110?
A: Tensile yield strength is 114 MPa (ASTM) / 165 MPa (ISO); tensile break strength is 116 MPa (ASTM) / 165 MPa (ISO).
Q11: What is the tensile modulus of ULTEM HU2110?
A: The tensile modulus is 4,610 MPa (ASTM) / 9,500 MPa (ISO).
Q12: What is the heat deflection temperature of ULTEM HU2110?
A: Heat deflection temperature is 208°C at 1.82 MPa (ASTM) and 205°C at 1.80 MPa (ISO).
Q13: What is the difference between ULTEM HU2100 and ULTEM HU2110?
A: ULTEM HU2110 offers enhanced flow (MFI 11.3 vs 7 g/10min) compared to HU2100. Both grades contain 10% glass fiber reinforcement, are standard flow, biocompatible, sterilizable, and suitable for healthcare applications. HU2110 also has lower shrinkage (0.20-0.40% vs 0.5-0.6%).
Q14: What processing methods can be used for ULTEM HU2110?
A: ULTEM HU2110 is suitable for injection molding.
Q15: What is the recommended drying condition for ULTEM HU2110?
A: Dry at 150°C for 4-6 hours.
Q16: What is the recommended melt temperature for injection molding ULTEM HU2110?
A: Recommended melt temperature is 350-400°C.
Q17: What is the recommended mold temperature for ULTEM HU2110?
A: Recommended mold temperature is 135-165°C.
Q18: What is the shrinkage of ULTEM HU2110?
A: Mold shrinkage (flow, 3.2mm) is 0.20-0.40%.
Q19: What is the lead time for orders?
A: Regular orders ship within 7-10 working days after payment confirmation. Large-volume or urgent orders can be negotiated separately.
CTA (Call to Action)
Ready to order ULTEM HU2110?
To get a precise quotation and professional technical support, please share:
-
Required quantity (kg)
-
Destination port or delivery address
-
Target application (surgical devices, pharmaceutical packaging, drug delivery, medical devices, sterilization trays, etc.)
-
Processing method (injection molding)
-
Color requirement (custom colors available via ColorXpress)
-
Document requirement (TDS, SDS, ISO 10993/USP Class VI certification, FDA compliance, UL, COA, etc.)
Sample Policy:
-
Samples are for laboratory validation tests only, not for production use.
-
Buyer bears international sample-shipping freight.
-
If bulk-product performance deviates from sample reference, SABIC official TDS serves as the authoritative benchmark.
Take action now:
-
📧 Email Us –
ruiqingchem@gmail.com -
📝 Send Inquiry – Use our quick inquiry form
-
💬 Live Chat – Click the bottom-right chat widget to speak directly with our team
After-Sales Support
| Service | Details |
|---|---|
| Quality Inspection Period | All quality-related claims must be submitted within 7 working-days after delivery, supported by test data and photographic evidence. |
| Return / Exchange Policy | Confirmed product defects caused by our side trigger replacement or refund. Terms and conditions apply. |
| Logistics Damage | Report shipping damage directly to carrier immediately upon goods receipt. We assist with claim-document preparation. |
| Technical Support | Remote technical guidance available. On-site troubleshooting can be arranged upon special request. |
| Export Documentation | We supply commercial invoice, packing list, bill of lading, COA, and additional compliance certificates (e.g., FDA, ISO 10993, USP Class VI, UL, RoHS) on request. |
Disclaimer
DISCLAIMER: All technical data is referenced from original SABIC typical values for ULTEM HU2110. Our company acts as authorized distributor/trader rather than original manufacturer. Final performance depends on processing conditions, mold design, and part geometry. Buyers shall independently validate product suitability for individual applications, particularly for medical device applications where regulatory compliance must be verified under end-use conditions. Our firm bears no liability for product failure caused by improper processing or improper usage. Always reference the latest SABIC official TDS of ULTEM HU2110 as the definitive specification.