描述
ULTEM Resin HU1110 is an enhanced flow, healthcare grade polyetherimide (PEI) resin manufactured by SABIC. As an authorized distributor and trader, we supply genuine SABIC materials with full traceability. For more product options and company information, please visit our website at https://szrqchem.com/.
ULTEM HU1110 is an unreinforced, amorphous PEI resin specifically developed for medical devices and pharmaceutical applications. It features a glass transition temperature of 217°C and enhanced flow characteristics for easier processing of complex, thin-walled parts.
This grade is biocompatible per ISO 10993 or USP Class VI and supports multiple sterilization methods including steam, gamma irradiation, ethylene oxide (EtO), and E-beam. It is FDA and EU food contact compliant and ECO conforming.
With its inherent flame retardancy (UL94 V-0 and 5VA), high stiffness, enhanced flow, hydrolytic stability, and chemical resistance, ULTEM HU1110 is the trusted choice for demanding healthcare environments where performance, safety, and reliability are critical. It is also suitable for additive manufacturing (3D printing).
Key Features of ULTEM HU1110
-
Healthcare Grade – Specifically developed for medical devices and pharmaceutical applications; biocompatible (ISO 10993 or USP Class VI)
-
Enhanced Flow – Improved flow characteristics (MFR 16 g/10min, MVR 21 cm³/10min) for easier processing and better mold filling of complex, thin-walled parts
-
Multiple Sterilization Compatibility – Supports steam, gamma irradiation, ethylene oxide (EtO), and E-beam sterilization
-
High Heat Resistance – Glass transition temperature of 217°C; HDT of 210°C at 1.80 MPa
-
Inherent Flame Retardancy – UL94 V-0 (0.75mm), V-2 (0.4mm), and 5VA ratings
-
High Stiffness & Strength – Tensile modulus of 3,500 MPa; tensile yield strength of 110 MPa
-
Excellent Dimensional Stability – Low shrinkage (0.50-0.70%) and low creep sensitivity
-
Food Contact Compliant – FDA and EU food contact compliant
-
Good Chemical Resistance – Excellent resistance to automotive fluids, aircraft fluids, aliphatic hydrocarbons, alcohols, acids, and weak aqueous solutions
-
Hydrolytic Stability – Good resistance to moisture and hydrolysis
-
Low Smoke & Low Toxicity – Inherently low smoke and toxicity
-
ECO Conforming – Meets environmental compliance standards
-
PFAS-Free – No PFAS intentionally added during manufacturing
-
Versatile Processing – Suitable for injection molding; also compatible with additive manufacturing (3D printing)
Comparison: ULTEM HU1100 vs ULTEM HU1110
| Property | ULTEM HU1100 | ULTEM HU1110 |
|---|---|---|
| Flow Type | Standard Flow | Enhanced Flow |
| MFR (337°C/6.6kg) | 8.8 g/10min | 16 g/10min |
| MVR (360°C/5kg) | 16 cm³/10min | 21 cm³/10min |
| Density (ISO) | 1.27 g/cm³ | 1.27 g/cm³ |
| Tg | 217°C | 217°C |
| HDT (1.80 MPa) | 188°C | 210°C |
| Tensile Modulus | 3,200 MPa | 3,500 MPa |
| Yield Stress | 105 MPa | 110 MPa |
| UL 94 | V-2 (0.4mm), 5VA | V-0 (0.75mm), V-2 (0.4mm), 5VA |
| Key Feature | Standard flow | Enhanced flow + higher HDT + higher stiffness |
ULTEM HU1110 offers enhanced flow for easier processing, a higher heat deflection temperature (210°C vs 188°C) , and higher stiffness (3,500 MPa vs 3,200 MPa) compared to HU1100, while maintaining the same healthcare-grade biocompatibility and sterilization capabilities.
Typical Applications for ULTEM HU1110
| Industry | Typical Applications |
|---|---|
| Surgical Devices | Surgical instruments, reusable medical devices – withstands multiple sterilization cycles |
| Pharmaceutical Packaging & Drug Delivery | Drug delivery systems, pharmaceutical packaging – biocompatible, FDA compliant |
| Ophthalmics | Ophthalmic surgical instruments and devices |
| Sterilization Trays & Containers | Sterilization trays, containers – supports steam, gamma, EtO, and E-beam sterilization |
| Respiratory & Sleep Therapy | Respiratory devices, sleep therapy equipment |
| Fluid & Blood Handling | Fluid handling components, blood handling devices |
| Medical Facility Infrastructure | Healthcare facility infrastructure components |
| Laboratory Ware & Clinical Diagnostics | Lab ware, clinical diagnostics equipment |
| Personal Accessories | Personal healthcare accessories |
| Additive Manufacturing | 3D printed medical device prototypes and components |
Typical Properties
| Property | HU1110 (ISO) | HU1110 (ASTM) | Unit | Test Method |
|---|---|---|---|---|
| Physical | ||||
| Density | 1.27 | 1.36 | g/cm³ | ISO 1183 / ASTM D792 |
| Melt Volume Rate (MVR) – 360°C/5kg | 21 | — | cm³/10min | ISO 1133 |
| Melt Flow Rate (MFR) – 337°C/6.6kg | — | 16 | g/10min | ASTM D1238 |
| Mold Shrinkage, Flow (3.2mm) | — | 0.50 – 0.70 | % | |
| Mechanical | ||||
| Tensile Modulus | 3,500 | — | MPa | ISO 527 |
| Tensile Strength (Yield) | 110 | 110 | MPa | ISO 527 / ASTM D638 |
| Tensile Strength (Break) | — | — | MPa | — |
| Yield Strain | 6 | — | % | ISO 527 |
| Elongation at Break | 50 | — | % | ISO 527 |
| Flexural Modulus | 3,300 | — | MPa | ISO 178 |
| Impact | ||||
| Izod Impact (Notched, 23°C) | 4 | — | kJ/m² | ISO 180/1A |
| Izod Impact (Notched, -30°C) | 4 | — | kJ/m² | ISO 180/1A |
| Charpy Impact (Notched, 23°C) | 5 | — | kJ/m² | ISO 179/1eA |
| Ball Indentation Hardness | 145 | — | MPa | ISO 2039-1 |
| Thermal | ||||
| Glass Transition Temperature (Tg) | 217 | 217 | °C | |
| Heat Deflection Temp. (1.80 MPa) | 210 | — | °C | ISO 75-1/-2 |
| Vicat Softening Temp. (A) | 210 | — | °C | ISO 306 |
| Vicat Softening Temp. (B) | 200 | — | °C | ISO 306 |
| Vicat Softening Temp. (120°C/h 50N) | 205 | — | °C | ISO 306 |
| UL RTI (Elec/Imp/Str) | 170 / 170 / 170 | — | °C | UL 746 |
| Flammability | ||||
| UL 94 Flammability | V-0 (0.75mm), V-2 (0.4mm), 5VA | — | — | UL 94 |
| Glow Wire Flammability Index (GWFI, 3.2mm) | 960 | — | °C | IEC 60695-2-12 |
| Other | ||||
| Water Absorption (Saturation) | 1.2 | — | % | ISO 62 |
Important Notes on Typical Data:
-
Values listed are typical and sourced from SABIC official data sheets. They do not constitute binding product specification.
-
Batch-to-batch deviations may exist. For critical applications, validate performance with batch-specific COA certificate.
-
Final performance depends on processing conditions, mold design, and part geometry.
-
SABIC official TDS shall serve as definitive technical reference. Request the latest official TDS from our sales team.
Processing Guidelines (Injection Molding)
| Parameter | Recommended Conditions | |
|---|---|---|
| Drying | ||
| Drying Temperature | 150°C | |
| Drying Time | 4 – 6 hours | |
| Maximum Moisture Content | ≤0.02% | |
| Injection Molding | ||
| Suggested Shot Size | 40 – 60% of cylinder capacity | |
| Rear Temperature | — | |
| Middle Temperature | — | |
| Front Temperature | — | |
| Nozzle Temperature | — | |
| Processing (Melt) Temperature | 350 – 400°C | |
| Mold Temperature | 135 – 165°C | |
| Back Pressure | 0.3 – 0.7 MPa | |
| Screw Speed | 40 – 70 rpm | |
| Vent Depth | 0.025 – 0.076 mm |
Critical Processing Warnings:
-
Drying: ULTEM HU1110 is hygroscopic and must be dried to ≤0.02% moisture before processing. Dry at 150°C for 4-6 hours.
-
Enhanced Flow: This grade offers enhanced flow characteristics (MFR 16 g/10min, MVR 21 cm³/10min) for easier processing and better mold filling of complex, thin-walled parts.
-
Melt Temperature: Recommended melt temperature range is 350-400°C. Avoid excessive residence times to prevent thermal degradation.
-
Mold Temperature: Higher mold temperatures (135-165°C) improve flow and reduce residual stress.
-
Healthcare Applications: This grade is specifically designed for medical devices and pharmaceutical applications. It is biocompatible (ISO 10993 or USP Class VI) and healthcare management of change applies.
-
Sterilization: ULTEM HU1110 supports steam, gamma, EtO, and E-beam sterilization. Verify compatibility with your specific sterilization protocol.
-
Food Contact: This material is food contact compliant in most jurisdictions – exceptions may exist, request a declaration for details.
-
PFAS-Free: This product does not contain PFAS intentionally added during manufacturing.
-
Gate Design: Use large gates and runners to minimize flow resistance and reduce molded-in stress.
-
Regrind: Regrind can be used up to 20-25% with virgin material, provided it is clean and properly dried.
Related Products
-
Explore PEI / Polyetherimide – Browse all ULTEM PEI resin options
-
Explore Engineering Plastics – Browse all engineering plastic materials
-
ULTEM HU1100 – Healthcare Grade PEI – Standard flow healthcare PEI
-
ULTEM HU1004 – Healthcare Grade PEI Blend – Healthcare PEI with improved ductility and enhanced hydrolytic stability
-
About Our Company – Learn more about our supply capabilities and quality assurance
Technical Documents
| Document Type | Description & Source |
|---|---|
| SABIC Official TDS | Complete physical, thermal, and mechanical properties of ULTEM HU1110 |
| SABIC Official SDS | GHS-compliant chemical safety documentation |
| UL Yellow Card | UL certification E121562-100044748 |
| ISO 10993 / USP Class VI | Biocompatibility certification |
| FDA Compliance Declaration | FDA food contact compliance |
| EU Food Contact Compliance | European food contact compliance |
| COA (Certificate of Analysis) | Batch-specific quality certification |
| Processing Guide | Detailed processing guidelines for ULTEM HU1110 |
Request any document above by:
-
Email:
ruiqingchem@gmail.com -
Online form: Our contact page
We reply within one working business day. Please clearly state product (ULTEM HU1110) and document type you require.
FAQ
Q1: What is ULTEM HU1110 and what is it used for?
A: ULTEM HU1110 is an enhanced flow, healthcare grade polyetherimide (PEI) resin manufactured by SABIC. It is specifically developed for medical devices and pharmaceutical applications. It is widely used in surgical instruments, pharmaceutical packaging, drug delivery systems, sterilization trays, laboratory ware, ophthalmics, respiratory & sleep therapy devices, fluid & blood handling components, and general healthcare equipment.
Q2: Is ULTEM HU1110 biocompatible?
A: Yes. ULTEM HU1110 is biocompatible per ISO 10993 or USP Class VI, making it suitable for regulated medical and pharmaceutical applications.
Q3: Is ULTEM HU1110 FDA compliant?
A: Yes. ULTEM HU1110 is FDA and EU food contact compliant. It is food contact compliant in most jurisdictions – exceptions may exist, request a declaration for details.
Q4: What sterilization methods can ULTEM HU1110 withstand?
A: ULTEM HU1110 supports steam sterilization, gamma irradiation, ethylene oxide (EtO), and E-beam sterilization.
Q5: What is the glass transition temperature of ULTEM HU1110?
A: The glass transition temperature (Tg) is 217°C.
Q6: What is the density of ULTEM HU1110?
A: Density is 1.27 g/cm³ (ISO 1183) and specific gravity is 1.36 g/cm³ (ASTM D792) .
Q7: Is ULTEM HU1110 flame retardant?
A: Yes. ULTEM HU1110 is inherently flame retardant with UL94 V-0 (0.75mm) , V-2 (0.4mm) , and 5VA ratings.
Q8: Is ULTEM HU1110 transparent?
A: Yes. ULTEM HU1110 is transparent, with all colors customizable.
Q9: Is ULTEM HU1110 PFAS-free?
A: Yes. ULTEM HU1110 has no PFAS intentionally added during manufacturing.
Q10: What is the melt flow rate of ULTEM HU1110?
A: The Melt Flow Rate (MFR) is 16 g/10min at 337°C, 6.6kg; the Melt Volume Rate (MVR) is 21 cm³/10min at 360°C, 5kg.
Q11: What is the tensile strength of ULTEM HU1110?
A: Tensile yield strength is 110 MPa.
Q12: What is the tensile modulus of ULTEM HU1110?
A: The tensile modulus is 3,500 MPa.
Q13: What is the heat deflection temperature of ULTEM HU1110?
A: Heat deflection temperature is 210°C at 1.80 MPa.
Q14: What is the difference between ULTEM HU1100 and ULTEM HU1110?
A: ULTEM HU1110 offers enhanced flow (MFR 16 vs 8.8 g/10min), a higher heat deflection temperature (210°C vs 188°C) , and higher stiffness (3,500 MPa vs 3,200 MPa) compared to HU1100, while maintaining the same healthcare-grade biocompatibility and sterilization capabilities.
Q15: What processing methods can be used for ULTEM HU1110?
A: ULTEM HU1110 is suitable for injection molding and is also compatible with additive manufacturing (3D printing) .
Q16: What is the recommended drying condition for ULTEM HU1110?
A: Dry at 150°C for 4-6 hours.
Q17: What is the recommended melt temperature for injection molding ULTEM HU1110?
A: Recommended melt temperature is 350-400°C.
Q18: What is the recommended mold temperature for ULTEM HU1110?
A: Recommended mold temperature is 135-165°C.
Q19: What is the lead time for orders?
A: Regular orders ship within 7-10 working days after payment confirmation. Large-volume or urgent orders can be negotiated separately.
CTA (Call to Action)
Ready to order ULTEM HU1110?
To get a precise quotation and professional technical support, please share:
-
Required quantity (kg)
-
Destination port or delivery address
-
Target application (surgical devices, pharmaceutical packaging, drug delivery, ophthalmics, respiratory, fluid handling, medical devices, etc.)
-
Processing method (injection molding, additive manufacturing, etc.)
-
Color requirement (transparent or custom color)
-
Document requirement (TDS, SDS, ISO 10993/USP Class VI certification, FDA compliance, UL, COA, etc.)
Sample Policy:
-
Samples are for laboratory validation tests only, not for production use.
-
Buyer bears international sample-shipping freight.
-
If bulk-product performance deviates from sample reference, SABIC official TDS serves as the authoritative benchmark.
Take action now:
-
📧 Email Us –
ruiqingchem@gmail.com -
📝 Send Inquiry – Use our quick inquiry form
-
💬 Live Chat – Click the bottom-right chat widget to speak directly with our team
After-Sales Support
| Service | Details |
|---|---|
| Quality Inspection Period | All quality-related claims must be submitted within 7 working-days after delivery, supported by test data and photographic evidence. |
| Return / Exchange Policy | Confirmed product defects caused by our side trigger replacement or refund. Terms and conditions apply. |
| Logistics Damage | Report shipping damage directly to carrier immediately upon goods receipt. We assist with claim-document preparation. |
| Technical Support | Remote technical guidance available. On-site troubleshooting can be arranged upon special request. |
| Export Documentation | We supply commercial invoice, packing list, bill of lading, COA, and additional compliance certificates (e.g., FDA, ISO 10993, USP Class VI, UL, RoHS) on request. |
Disclaimer
DISCLAIMER: All technical data is referenced from original SABIC typical values for ULTEM HU1110. Our company acts as authorized distributor/trader rather than original manufacturer. Final performance depends on processing conditions, mold design, and part geometry. Buyers shall independently validate product suitability for individual applications, particularly for medical device applications where regulatory compliance must be verified under end-use conditions. Our firm bears no liability for product failure caused by improper processing or improper usage. Always reference the latest SABIC official TDS of ULTEM HU1110 as the definitive specification.