CYROLITE CG-97 Lipid Resistant Medical Acrylic Copolymer
Material: PMMA-based Copolymer
Impact: 143 J/m
Lipid Resistance: Superior
Medical: USP Class VI
Packing: 1500 lb boxes
CYROLITE CG-97 offers superior lipid resistance combined with the highest impact strength (143 J/m) in the CYROLITE family and excellent gamma sterilization color stability.
CYROLITE CG-97 is a lipid resistant, medical grade PMMA-based copolymer designed for medical device applications requiring superior lipid resistance and gamma sterilization stability. With a notched Izod impact strength of 143 J/m at 23°C — the highest in the CYROLITE family — this material delivers exceptional durability for demanding medical applications. Its superior lipid resistance ensures reliable performance in contact with fatty substances, making it ideal for IV filtration and pediatric medical devices.
CYROLITE CG-97 offers excellent gamma sterilization color stability, maintaining its optical clarity and appearance after gamma radiation exposure. It provides 87% light transmission with 5.0% haze (3.2mm), ensuring good visibility of fluid pathways. The material meets USP Class VI (colorless) and ISO 10993-1 biocompatibility requirements, and offers resistance to body fluids and many chemicals. It is processable on standard injection molding and extrusion equipment with 3-zone general purpose screws. Typical applications include needle hubs, IV filters, lab filters, and pediatric filters where lipid resistance, gamma stability, and high impact resistance are critical.
Genuine Roehm CYROLITE Imported Stock and Technical Support
We supply stable spot inventory of genuine CYROLITE CG-97 lipid resistant medical grade acrylic copolymer. Official TDS, batch COA, and biocompatibility documentation (USP Class VI, ISO 10993) are available for medical device applications.
Request CYROLITE CG-97 Quotation, TDS, and Sample
Complete TDS, COA, and regulatory documentation available
Core Advantages of CYROLITE CG-97
- Superior lipid resistance — reliable performance in contact with fatty substances
- Highest impact strength: 143 J/m — the toughest in the CYROLITE family
- Excellent gamma sterilization color stability — maintains clarity after gamma exposure
- Medical grade compliance — USP Class VI (colorless) and ISO 10993-1
- Good optical clarity — 87% transmission, 5.0% haze
- Multiple sterilization compatibility — EtO, gamma, and E-beam
- Chemical and body fluid resistance — suitable for medical fluid contact
- Excellent bonding to PVC — thermal, ultrasonic, and laser weldable
Main Applications
- Needle hubs — syringe and catheter components requiring lipid resistance
- IV filters — intravenous filtration devices
- Lab filters — laboratory filtration components
- Pediatric filters — specialized filtration for pediatric applications
- Medical device components — applications requiring lipid resistance and gamma stability
Full Technical Parameters
| Property | Typical Value | Test Method |
| Material Type | PMMA-based copolymer | — |
| Medical Compliance | USP Class VI (colorless), ISO 10993-1 | — |
| Notched Izod Impact (23°C) | 143 J/m | ASTM D256 |
| Light Transmission (3.2mm) | 87% | ASTM D1003 |
| Haze (3.2mm) | 5.0% | ASTM D1003 |
| Melt Flow Rate (230°C/5.0kg) | 1.8 g/10min | ASTM D1238 |
| Tensile Strength | 36.3 MPa | ASTM D638 |
| Tensile Modulus | 1.9 GPa | ASTM D638 |
| Tensile Elongation @ Break | 13.9% | ASTM D638 |
| Flexural Strength | 67.6 MPa | ASTM D790 |
| Flexural Modulus | 1.8 GPa | ASTM D790 |
| Vicat Softening Point | 90°C | ASTM D1525 |
| HDT (1.8 MPa) | 70°C | ASTM D648 |
| Specific Gravity | 1.08 | ASTM D792 |
| Mold Shrinkage | 0.005-0.007 in/in | ASTM D955 |
| Lipid Resistance | Superior | — |
| Gamma Sterilization Stability | Excellent color stability | — |
| Sterilization | EtO, Gamma, E-beam | — |
Note: All listed figures are typical values and may vary by production batch. Complete independent qualification testing is required before mass production deployment.
Recommended Processing Conditions
| Parameter | Recommended Value |
| Processing Method | Injection Molding / Extrusion |
| Screw Type | 3-zone general purpose screw |
| Melt Temperature | 230-250°C (typical) |
| Mold Temperature | 50-80°C (typical) |
Handling and Storage Recommendations
| Storage Rules | Store in dry, cool conditions away from direct sunlight and heat sources. |
| Packaging | 1500 lb gaylor boxes; other packaging available on request. |
| Operation Protection | Follow standard safety practices for handling thermoplastic pellets. Use appropriate PPE during processing. |
Official Technical Documentation
| Document Type | Document Introduction | Document Request |
| TDS | CYROLITE CG-97 original factory technical data sheet | Request TDS |
| COA | Batch-specific certificate of analysis | Request COA |
| Biocompatibility | USP Class VI and ISO 10993-1 documentation | Request Documentation |
Frequently Asked Questions
What is CYROLITE CG-97?
CYROLITE CG-97 is a lipid resistant medical grade acrylic copolymer offering superior resistance to lipids, excellent gamma sterilization color stability, and the highest impact strength (143 J/m) in the CYROLITE family for medical device applications.
What is the impact strength of CYROLITE CG-97?
CYROLITE CG-97 offers a notched Izod impact strength of 143 J/m at 23°C — the highest in the CYROLITE G-20 series — providing exceptional durability for medical device components.
What is lipid resistance and why is it important?
Lipid resistance means the material can withstand contact with fatty substances without degradation. CYROLITE CG-97 offers superior lipid resistance, making it ideal for medical devices that may contact lipid-containing fluids.
What medical certifications does CYROLITE CG-97 hold?
CYROLITE CG-97 meets USP Class VI (colorless) and ISO 10993-1 biocompatibility requirements, making it suitable for medical device applications requiring patient contact.
What applications is CYROLITE CG-97 suitable for?
CYROLITE CG-97 is ideal for needle hubs, IV filters, lab filters, pediatric filters, and other medical device components requiring lipid resistance, gamma stability, and high impact resistance.
What is the melt flow rate of CYROLITE CG-97?
CYROLITE CG-97 has a melt flow rate of 1.8 g/10min (230°C/5.0kg), offering good flow for injection molding applications.
Is CYROLITE CG-97 bondable to PVC tubing?
Yes. CYROLITE CG-97 offers excellent bonding to PVC tubing and can be thermal bonded, ultrasonic welded, and laser welded.
Related CYROLITE Products
Compare CYROLITE medical grade polymers for different application requirements.
| Product | Key Feature | Impact (J/m) | MFR | Core Application |
| CG-97 | Lipid resistant + gamma stable | 143 | 1.8 | Needle hubs, IV filters |
| GS-90 | High clarity + gamma stable | 107 | 6.5 | Y-sites, luer locks |
| G-20 | General medical grade | 101 | 2.6 | General medical devices |
Get CYROLITE CG-97 Bulk Pricing and Technical Support
We supply genuine CYROLITE CG-97 lipid resistant medical grade acrylic copolymer for medical device applications. Contact us for bulk pricing, sample availability, technical documents, and application support.
Request CYROLITE CG-97 Technical Details
Disclaimer: All technical data on this page are for general guidance only and are not product specifications. Buyers must carry out independent trials and verify suitability before bulk ordering. Actual values may vary between production lots.