描述
ULTEM Resin 2100 is a 10% glass fiber reinforced, amorphous polyetherimide (PEI) engineering thermoplastic manufactured by SABIC. As an authorized distributor and trader, we supply genuine SABIC materials with full traceability. For more product options and company information, please visit our website at https://szrqchem.com/.
ULTEM 2100 is a 10% glass fiber reinforced, general purpose grade that delivers an outstanding balance of mechanical, thermal, and electrical properties with enhanced stiffness. Key attributes include:
-
10% Glass Fiber Reinforcement – Increased stiffness and strength compared to unreinforced grades
-
High Heat Resistance – Glass transition temperature (Tg) of 217°C; RTI of 170°C
-
Inherent Flame Retardancy – UL94 V-0 and 5VA ratings without additives
-
Medical & Food Contact Approved – ISO 10993 or USP Class VI biocompatible; US FDA & European Food Contact approved
-
Sterilizable – Supports steam, gamma, EtO, and E-beam sterilization
-
High Stiffness & Strength – Tensile modulus of 4,500 MPa (ISO) / 4,680 MPa (ASTM) ; yield stress of 115 MPa
-
Excellent Dimensional Stability – Low creep sensitivity and low shrinkage
-
Hydrolytic Stability – Good resistance to moisture and hydrolysis
-
Good Metal Adhesion – Suitable for applications requiring metal bonding
Key Features of ULTEM 2100
-
10% Glass Fiber Reinforced – Provides increased stiffness, strength, and dimensional stability compared to unreinforced grades
-
Medical Device Compatible – Biocompatible per ISO 10993 or USP Class VI; suitable for medical devices and pharmaceutical applications
-
Food Contact Approved – Complies with US FDA and European Food Contact regulations
-
Multiple Sterilization Options – Supports steam, gamma, EtO, and E-beam sterilization
-
High Heat Resistance – Glass transition temperature of 217°C; RTI of 170°C
-
Inherent Flame Retardancy – UL94 V-0 and 5VA ratings; oxygen index of 47%
-
High Mechanical Strength – Tensile modulus of 4,500 MPa (ISO) / 4,680 MPa (ASTM) ; yield stress of 115 MPa
-
Excellent Dimensional Stability – Low creep sensitivity, low shrinkage (0.5-0.6%), and low warpage
-
Good Chemical Resistance – Resists automotive fluids, aircraft fluids, alcohols, acids, and weak aqueous solutions
-
Hydrolytic Stability – Good resistance to moisture and hydrolysis
-
Low Smoke & Toxicity – Inherently low smoke and toxicity; suitable for aerospace and mass transit applications
-
NSF 51 Listed – Certified for food equipment applications
-
ECO Conforming – Meets environmental compliance standards
-
Versatile Processing – Suitable for injection molding
Typical Applications for ULTEM 2100
| Industry | Typical Applications |
|---|---|
| Medical Devices | Sterilizable surgical instruments, medical device components, pharmaceutical equipment – ISO 10993/USP Class VI biocompatible |
| Aerospace & Mass Transportation | Aircraft interiors, heavy truck, bus, specialty vehicles – low smoke and toxicity |
| Electrical & Electronics | High-temperature connectors, IC sockets, electrical components, electronics material handling |
| Automotive | Under-hood sensors, connectors, interior components – FORD WSF-M4D736-A specification |
| Semiconductor | High-temperature wafer carriers, sockets, and fluid handling components |
| Consumer & Industrial | Home & commercial appliances, rigid packaging, sports & leisure, building & construction |
| Defense | Defense applications requiring high performance and flame retardancy |
| Energy | Hydrocarbon & wind energy components |
Typical Properties
| Property | ULTEM 2100 | Unit | Test Method |
|---|---|---|---|
| Density / Specific Gravity | 1.34 | g/cm³ | ASTM D792 / ISO 1183 |
| Melt Flow Rate (MFR) – 337°C/6.6kg | 7 | g/10min | ASTM D1238 |
| Melt Volume Rate (MVR) – 360°C/5kg | 9 | cm³/10min | ISO 1133 |
| Glass Transition Temperature (Tg) | 217 | °C | |
| Heat Deflection Temp. (1.8MPa) – ASTM | – | °C | ASTM D648 |
| Heat Deflection Temp. (1.8MPa) – ISO | 205 | °C | ISO 75-1/-2 |
| Vicat Softening Temperature | 212-217 | °C | ISO 306 |
| RTI (Elec/Imp/Str) | 170 | °C | UL 746 |
| Tensile Modulus – ASTM | 4,680 | MPa | ASTM D638 |
| Tensile Modulus – ISO | 4,500 | MPa | ISO 527 |
| Tensile Strength (Yield) – ASTM | 114 | MPa | ASTM D638 |
| Tensile Strength (Break) – ASTM | 115 | MPa | ASTM D638 |
| Yield Stress – ISO | 115 | MPa | ISO 527 |
| Stress at Break – ISO | 115 | MPa | ISO 527 |
| Yield Strain – ISO | 4 | % | ISO 527 |
| Elongation at Yield – ASTM | 6 | % | ASTM D638 |
| Elongation at Break – ASTM | 6 | % | ASTM D638 |
| Flexural Modulus – ASTM | 5,500 | MPa | ASTM D790 |
| Flexural Modulus – ISO | 4,500 | MPa | ISO 178 |
| Izod Impact Notched – ASTM | 53 | J/m | ASTM D256 |
| Charpy Notched Impact – ISO | 7 | kJ/m² | ISO 179/1eA |
| Izod Impact Unnotched – ISO | 30 | kJ/m² | ISO 180/1U |
| Mold Shrinkage (Flow) | 0.5-0.6 | % | SABIC Method |
| Water Absorption (Saturation) | 1.0 | % | ISO 62 |
| Volume Resistivity | 1×10¹⁷ | Ω·cm | ASTM D257 |
| Arc Resistance | 60-119 | s | ASTM D495 |
| Comparative Tracking Index (CTI) | 100-174 | V | UL 746A |
| UL 94 Flammability | V-0 (0.75mm), 5VA (3.0mm) | – | UL 94 |
Important Notes on Typical Data:
-
Values listed are typical and sourced from SABIC official data sheets. They do not constitute binding product specification.
-
Batch-to-batch deviations may exist. For critical applications, validate performance with batch-specific COA certificate.
-
Final performance depends on processing conditions, mold design, and part geometry.
-
SABIC official TDS shall serve as definitive technical reference. Request the latest official TDS from our sales team.
Processing Guidelines
| Parameter | Recommended Conditions |
|---|---|
| Drying | 150°C for 4-6 hours |
| Recommended Moisture | <0.02% |
| Hopper Temperature | 80-120°C |
| Front Zone Temperature | 360-415°C |
| Mold Temperature | 135-165°C |
Critical Processing Warnings:
-
Drying: ULTEM 2100 is hygroscopic and must be dried to <0.02% moisture before processing. Dry at 150°C for 4-6 hours.
-
Melt Temperature: Recommended melt temperature range is 360-415°C. Avoid excessive residence times to prevent thermal degradation.
-
Mold Temperature: Higher mold temperatures (135-165°C) improve flow and reduce residual stress.
-
Gate Design: Use large gates and runners to minimize flow resistance and reduce molded-in stress.
-
Regrind: Regrind can be used up to 20-25% with virgin material, provided it is clean and properly dried.
Related Products
-
Explore PEI / Polyetherimide – Browse all ULTEM PEI resin options
-
Explore Engineering Plastics – Browse all engineering plastic materials
-
About Our Company – Learn more about our supply capabilities and quality assurance
Technical Documents
| Document Type | Description & Source |
|---|---|
| SABIC Official TDS | Complete physical, thermal, and mechanical properties of ULTEM 2100 |
| SABIC Official SDS | GHS-compliant chemical safety documentation |
| UL Yellow Card | UL certification E121562 |
| FDA Compliance Declaration | US FDA food contact compliance |
| EU Food Contact Compliance | European food contact compliance |
| NSF 51 Listing | Food equipment certification |
| ISO 10993 / USP Class VI | Biocompatibility certification |
| COA (Certificate of Analysis) | Batch-specific quality certification |
| Processing Guide | Detailed processing guidelines for ULTEM resins |
Request any document above by:
-
Email:
ruiqingchem@gmail.com -
Online form: Our contact page
We reply within one working business day. Please clearly state product (ULTEM 2100) and document type you require.
FAQ
Q1: What is ULTEM 2100 and what is it used for?
A: ULTEM 2100 is a 10% glass fiber reinforced polyetherimide (PEI) resin manufactured by SABIC. It combines high heat resistance (Tg 217°C), inherent flame retardancy (UL94 V-0 & 5VA), and enhanced stiffness from glass fiber reinforcement. It is widely used in medical devices, aerospace interiors, electrical/electronic components, automotive under-hood applications, semiconductor equipment, and industrial components.
Q2: Is ULTEM 2100 FDA compliant?
A: Yes. ULTEM 2100 complies with US FDA and European Food Contact regulations. It is also NSF 51 listed.
Q3: Is ULTEM 2100 biocompatible?
A: Yes. ULTEM 2100 (HU2100 variant) is biocompatible per ISO 10993 or USP Class VI, making it suitable for medical devices and pharmaceutical applications.
Q4: Can ULTEM 2100 be sterilized?
A: Yes. ULTEM 2100 supports steam, gamma, EtO, and E-beam sterilization.
Q5: What is the glass transition temperature of ULTEM 2100?
A: The glass transition temperature (Tg) is 217°C.
Q6: What is the density of ULTEM 2100?
A: The density is 1.34 g/cm³.
Q7: Is ULTEM 2100 flame retardant?
A: Yes. ULTEM 2100 is inherently flame retardant with UL94 V-0 and 5VA ratings.
Q8: What is the glass fiber content of ULTEM 2100?
A: ULTEM 2100 contains 10% glass fiber reinforcement.
Q9: What is the tensile modulus of ULTEM 2100?
A: Tensile modulus is 4,500 MPa (ISO) / 4,680 MPa (ASTM) .
Q10: What is the lead time for orders?
A: Regular orders ship within 7-10 working days after payment confirmation. Large-volume or urgent orders can be negotiated separately.
CTA (Call to Action)
Ready to order ULTEM 2100?
To get a precise quotation and professional technical support, please share:
-
Required quantity (kg)
-
Destination port or delivery address
-
Target application (medical, aerospace, electrical, automotive, etc.)
-
Processing method (injection molding, etc.)
-
Color requirement (natural amber or custom color)
-
Document requirement (TDS, SDS, UL, FDA compliance, ISO 10993, COA, etc.)
Sample Policy:
-
Samples are for laboratory validation tests only, not for production use.
-
Buyer bears international sample-shipping freight.
-
If bulk-product performance deviates from sample reference, SABIC official TDS serves as the authoritative benchmark.
Take action now:
-
📧 Email Us –
ruiqingchem@gmail.com -
📝 Send Inquiry – Use our quick inquiry form
-
💬 Live Chat – Click the bottom-right chat widget to speak directly with our team
After-Sales Support
| Service | Details |
|---|---|
| Quality Inspection Period | All quality-related claims must be submitted within 7 working-days after delivery, supported by test data and photographic evidence. |
| Return / Exchange Policy | Confirmed product defects caused by our side trigger replacement or refund. Terms and conditions apply. |
| Logistics Damage | Report shipping damage directly to carrier immediately upon goods receipt. We assist with claim-document preparation. |
| Technical Support | Remote technical guidance available. On-site troubleshooting can be arranged upon special request. |
| Export Documentation | We supply commercial invoice, packing list, bill of lading, COA, and additional compliance certificates (e.g., FDA, EU, NSF 51, ISO 10993, UL, RoHS) on request. |
Disclaimer
DISCLAIMER: All technical data is referenced from original SABIC typical values for ULTEM 2100. Our company acts as authorized distributor/trader rather than original manufacturer. Final performance depends on processing conditions, mold design, and part geometry. Buyers shall independently validate product suitability for individual applications. Our firm bears no liability for product failure caused by improper processing or improper usage. Always reference the latest SABIC official TDS of ULTEM 2100 as the definitive specification.