描述
3M Novec 71D90 Engineered Fluid Aerosol Cleaning Solvent
Type: Aerosol Cleaning Blend
Composition: 90% t-DCE / 10% HFE
Boiling Point: 42.6°C
GWP: 32
Packing: 5 kg / 20 kg drum
3M Novec 71D90 Engineered Fluid is a high-solvency blend of 90% trans-1,2-dichloroethylene (t-DCE) and 10% methyl nonafluorobutyl ether (HFE-7100). Designed specifically for aerosol cleaning formulations, this mixture exhibits azeotrope-like behavior with a depressed boiling point of 42.6°C. Novec 71D90 offers excellent solvency as a replacement for HCFC-141b in aerosol cleaners, delivering zero ozone depletion potential and an ultra-low GWP of 32 — one of the lowest among cleaning solvents. The high t-DCE content provides increased formulating flexibility for precision cleaning applications.
Novec 71D90 is nonflammable with no closed cup flashpoint under normal storage conditions. However, due to the differential evaporation rates of its components, the composition will change during evaporation, potentially creating a flammable liquid. Therefore, this product is not recommended for vapor degreasing or cold cleaning baths — it is intended exclusively for aerosol cleaning formulations. With t-DCE not classified as a Hazardous Air Pollutant (HAP), Novec 71D90 offers a favorable regulatory profile compared to traditional chlorinated solvents.
Genuine 3M Imported Stock and Technical Support
We supply stable spot inventory of genuine 3M Novec 71D90 engineered fluid. Official TDS, SDS, and batch COA documents are available for aerosol cleaning formulations and specialty solvent applications.
Request Novec 71D90 Quotation, TDS, SDS, and Sample
Complete SDS, COA, and technical documentation available
Core Advantages of 3M Novec 71D90 Engineered Fluid
- High t-DCE content: 90% — superior solvency for demanding cleaning applications
- Ultra-low GWP: 32 — one of the lowest global warming potential cleaning solvents available
- Zero ozone depletion potential — environmentally sustainable alternative to HCFC-141b
- Azeotrope-like behavior — depressed boiling point for consistent aerosol performance
- Nonflammable — no closed cup flashpoint under normal storage conditions
- Favorable regulatory profile — t-DCE is not a Hazardous Air Pollutant (HAP)
- Excellent formulating flexibility — ideal for aerosol cleaner formulations
- Proven HCFC-141b replacement — drop-in replacement for many aerosol applications
Main Applications
- Aerosol cleaning formulations — precision cleaning of electronic components and assemblies
- HCFC-141b replacement — direct replacement in aerosol cleaner products
- Specialty solvent applications — custom cleaning formulations requiring high solvency
- Industrial cleaning — removal of oils, greases, and contaminants
- Product development and testing — formulation development for new cleaning products
Novec 71D90 is not recommended for vapor degreasing or cold cleaning baths. Evaporation changes composition, potentially creating a flammable liquid. This product is designed exclusively for aerosol cleaning formulations.
Full Technical Parameters
| Property | Typical Value | Test Method |
| Composition | Methyl Nonafluorobutyl Ether (10%) + t-DCE (90%) | — |
| Appearance | Clear colorless liquid | Visual |
| Boiling Point | 42.6°C | ASTM D1078 |
| Freeze Point | -45°C | ASTM D97 |
| Liquid Density (25°C) | 1.26 g/ml | ASTM D891 |
| Surface Tension | 21.1 dynes/cm | — |
| Vapor Pressure (25°C) | 405 mmHg | — |
| Viscosity (25°C) | 0.40 cP | — |
| Heat of Vaporization | 64 cal/g | — |
| Ozone Depletion Potential | 0.00 | — |
| Global Warming Potential | 32 | — |
| Atmospheric Lifetime (HFE component) | 4.1 years | — |
| Atmospheric Lifetime (t-DCE) | 0.01 years | — |
| Flash Point | None | ASTM D3278-96e1 |
| Exposure Guideline (t-DCE, 8hr TWA) | 200 ppm | — |
| Exposure Guideline (HFE, 8hr TWA) | 750 ppm | — |
Note: All listed figures are typical values and may vary by production batch. Complete independent qualification testing is required before mass production deployment.
Handling and Storage Recommendations
| Storage Rules | Store sealed original containers below 38°C in a dry, well-ventilated area away from heat sources and direct sunlight. |
| Pressure Warning | Contents may be under pressure if shipped at elevated temperatures. Open closure slowly to vent pressure. |
| Forbidden Environments | Avoid exposure to open flames, strong oxidizing agents, and reactive metal powders. |
| Operation Protection | Maintain adequate ventilation. Wear nitrile protective gloves and anti-splash safety goggles during handling. |
Official Technical Documentation
| Document Type | Document Introduction | Document Request |
| TDS | 3M Novec 71D90 original factory technical data sheet | Request TDS |
| SDS | Safety data sheet covering transport, storage, and handling guidelines | Request SDS |
| COA | Batch-specific certificate of analysis | Request COA |
Frequently Asked Questions
What is 3M Novec 71D90 Engineered Fluid?
3M Novec 71D90 is a blend of 90% trans-1,2-dichloroethylene and 10% methyl nonafluorobutyl ether. It is specifically designed for aerosol cleaning formulations, offering excellent solvency with zero ozone depletion potential and ultra-low GWP of 32.
Why is Novec 71D90 not recommended for vapor degreasing?
Novec 71D90 will not maintain constant composition during evaporation due to differential evaporation rates of its components. Evaporation may change the composition, resulting in a potentially flammable liquid. Therefore, it is not recommended for vapor degreasing or cold cleaning baths.
What is the GWP of Novec 71D90?
Novec 71D90 has an ultra-low global warming potential (GWP) of 32 (100-year ITH), making it one of the lowest GWP cleaning solvents available.
Is Novec 71D90 flammable?
Novec 71D90 has no closed cup flashpoint and is nonflammable under normal storage conditions. However, evaporation can change composition and potentially create a flammable liquid, so it is not recommended for open bath applications.
What applications is Novec 71D90 suitable for?
Novec 71D90 is intended for aerosol cleaning formulations, replacing HCFC-141b in many aerosol cleaners. Its high t-DCE content (90%) provides increased formulating flexibility for precision cleaning applications.
Is Novec 71D90 a VOC or HAP?
t-DCE is designated as a VOC but is not considered a Hazardous Air Pollutant (HAP), making it less regulated than other chlorinated solvents like trichloroethylene or perchloroethylene.
Related 3M Novec Engineered Fluids
Compare 3M Novec engineered fluids for different cleaning and application requirements.
| Product Grade | Type | Composition | GWP | Core Application |
| Novec 71D90 | Aerosol blend | 90% t-DCE + 10% HFE | 32 | Aerosol cleaning formulations |
| Novec 71DA | Azeotropic blend | HFE + t-DCE + Ethanol | 170 | Defluxing |
| Novec 71DE | Azeotropic blend | HFE + t-DCE (50/50) | 160 | Medium-duty degreasing |
Get 3M Novec 71D90 Bulk Pricing and Technical Support
We supply genuine 3M Novec 71D90 engineered fluid for aerosol cleaning formulations and specialty solvent applications. Contact us for bulk pricing, sample availability, technical documents, and application support.
Request Novec 71D90 Technical Details
Disclaimer: All technical data on this page are for general guidance only and are not product specifications. Buyers must carry out independent trials and verify suitability before bulk ordering. Actual values may vary between production lots.