Hostaform MT SlideX 2404 is a low melt viscosity, tribologically modified POM‑C (Polyoxymethylene Copolymer) injection molding grade, genuinely manufactured by Celanese and imported as original product. As an authorized distributor and trader, we supply genuine material with full traceability and direct access to official Celanese technical documentation.

This unfilled acetal copolymer is a low melt viscosity injection molding grade designed for fast cycling and thin walled parts with tribological modification for use in demanding applications that require prevention of audible noise caused by stick-slip phenomenon and low friction and wear against plastics and metals.

Hostaform MT SlideX 2404 is a special grade developed for medical industry applications, containing low residual monomers and no animal-derived constituents. It complies with FDA 21 CFR 177.2470, is listed in the Drug Master File (DMF 11559) and the Device Master File (MAF 1079), and meets USP Class VI and ISO 10993 biocompatibility requirements. It is suitable for injection molding processing and is available with ECO‑B sustainable option. We hold regular stock, supporting small trial orders and large‑volume bulk shipments for demanding end‑users.

Key Features of Hostaform MT SlideX 2404

  • Low Melt Viscosity / High Flow – MVR of 25 cm³/10min (190°C/2.16kg), providing exceptional flow for thin wall parts and enabling fast cycling

  • Tribological Modified – Specially formulated for demanding applications requiring low friction and low wear against plastics and metals

  • Stick-Slip Noise Prevention – Prevents audible noise caused by stick-slip phenomenon for smooth and quiet operation

  • Medical Grade Compliance – Developed specifically for medical industry applications

  • Low Residual Monomers – Contains low residual monomers suitable for sensitive medical applications

  • No Animal-Derived Constituents – Formulated without animal products

  • Biocompatible – ISO 10993 and USP Class VI certified

  • FDA Compliant – FDA 21 CFR 177.2470 compliant and listed in Drug Master File (DMF 11559) and Device Master File (MAF 1079)

  • Good Mechanical Properties – Tensile modulus of 2550 MPa and yield stress of 55 MPa

  • Excellent Ductility – Nominal strain at break of 50%

  • Good Impact Resistance – Charpy notched impact strength of 5.5 kJ/m² at 23°C and -30°C

  • Sterilizable – Compatible with Ethylene Oxide (EtO) sterilization and steam sterilization

  • Sustainable Option – ECO‑B variant uses bio-based feedstocks via mass‑balance approach, ISCC Plus certified

  • Regional Availability – Available in North America, Europe, South and Central America, and Near East/Africa

Typical Applications for Hostaform MT SlideX 2404

Industry Typical Components & Considerations
Medical & Healthcare Drug delivery devices, inhalers, insulin injection pens, surgical instruments, portable diagnostic medical equipment. Fast cycling and thin wall capability enables high‑volume production of precision components.
Medical Devices Components requiring low friction, low wear, and medical compliance
Thin Wall Applications Thin walled parts requiring exceptional flowability and fast cycle times
Automotive Interior components, gears, bearings, fuel system components, door locks, seat belt systems
Electrical & Electronics Connectors, switches, coil formers, precision housings, low VOC components
Industrial Machinery Gears, cams, guide rails, pump valves, conveyor rollers, fasteners
Consumer Goods Household appliances, toys, zippers, stationery, precision metal replacement parts

Explore our full range of engineering plastics solutions for more industry‑specific case studies. See also our full POM product portfolio .

Material Advantages of Hostaform MT SlideX 2404

What makes Hostaform MT SlideX 2404 the preferred material for medical and high‑flow tribological applications? Below are its core practical advantages:

Low Melt Viscosity for Fast Cycling & Thin Walls
With an MVR of 25 cm³/10minHostaform MT SlideX 2404 offers exceptional flowability for filling thin wall geometries and enables fast cycling for high‑volume production.

Medical Grade Compliance
This grade is developed specifically for medical industry applications. It complies with ISO 10993 and USP Class VI biocompatibility standards, contains low residual monomers and no animal‑derived constituents, and is FDA 21 CFR compliant with DMF and MAF listings.

Tribological Performance
The proprietary SlideX tribological modification system provides excellent low friction and low wear against plastics and metals. It effectively prevents audible stick‑slip noise, ensuring smooth and quiet operation in demanding applications.

Excellent Mechanical Properties
With a tensile modulus of 2550 MPa, yield stress of 55 MPa, and nominal strain at break of 50%, this material delivers reliable structural performance with good ductility.

Sterilizable
Hostaform MT SlideX 2404 is compatible with both Ethylene Oxide (EtO) sterilization and steam sterilization (autoclaving), making it suitable for medical applications requiring sterilization.

Good Thermal Properties
Melting temperature of 166°C and heat deflection temperature of 90°C at 1.8 MPa ensure thermal stability during processing and service.

ECO‑B Sustainable Option
The ECO‑B variant uses a mass‑balance approach with biogenic feedstocks to offset fossil‑based raw materials and decrease greenhouse gas emissions, audited and certified according to ISCC Plus.

Heavy‑Metal Free
Environmentally friendly formulation.

Batch‑to‑Batch Consistency
Celanese manufactures this grade under strict ISO quality standards for consistent property across shipments.

Reliable Supply
We maintain active inventory and stable supply chains. For more supply‑chain details, visit our company background page .

Typical Properties (ISO Standards)

Typical properties of Hostaform MT SlideX 2404 measured to ISO standards are listed below:

Property Test Standard Typical Value Unit
Physical Properties
Density ISO 1183 1400 kg/m³
Melt Volume Flow Rate (MVR) ISO 1133 (190°C/2.16kg) 25 cm³/10min
Molding Shrinkage, Parallel ISO 294-4, 2577 1.9 %
Molding Shrinkage, Normal ISO 294-4, 2577 1.8 %
Water Absorption (23°C/sat) Sim. to ISO 62 0.6 %
Humidity Absorption (23°C/50% RH) Sim. to ISO 62 0.2 %
Mechanical Properties
Tensile Modulus ISO 527-1/-2 2550 MPa
Yield Stress ISO 527-1/-2 55 MPa
Yield Strain ISO 527-1/-2 7 %
Nominal Strain at Break ISO 527-1/-2 50 %
Flexural Modulus ISO 178 2300 MPa
Ball Indentation Hardness (H 358/30) ISO 2039-1 130 MPa
Charpy Impact Strength (23°C) ISO 179/1eU 160 kJ/m²
Charpy Impact Strength (-30°C) ISO 179/1eU 150 kJ/m²
Charpy Notched Impact (23°C) ISO 179/1eA 5.5 kJ/m²
Charpy Notched Impact (-30°C) ISO 179/1eA 5.5 kJ/m²
Poisson’s Ratio 0.38
Thermal Properties
Melting Temperature ISO 11357-1/-3 166 °C
Heat Deflection Temp (1.8 MPa) ISO 75-1/-2 90 °C
CLTE, Parallel ISO 11359-1/-2 140 E-6/K
CLTE, Normal ISO 11359-1/-2 140 E-6/K
Certifications
Medical Compliance ISO 10993, USP Class VI
Food Contact FDA 21 CFR, BfR

Important Notes on Typical Data:

  1. Values listed are typical and sourced from Celanese official data sheets for Hostaform MT SlideX 2404. They do not constitute binding product specification.

  2. Batch‑to‑batch deviations may exist. For critical applications, validate performance with batch‑specific COA certificate.

  3. Final part performance depends on component design, processing parameters and end‑use environment.

  4. Celanese original TDS shall serve as definitive technical reference. Request the latest official Hostaform MT SlideX 2404 TDS from our sales team.

Processing Guidelines (Injection Molding)

Recommended processing parameters for Hostaform MT SlideX 2404:

Parameter Recommended Setting
Drying Recommended Recommended
Drying Temperature 100°C
Drying Time 3 – 4 hours
Max. Processing Moisture Content ≤0.15%
Zone 1 Temperature 170 – 175°C
Optimum Melt Temperature 190 – 210°C
Optimum Mold Temperature 80 – 120°C

Critical Processing Warnings for Hostaform MT SlideX 2404:

  • Fast Cycling Capability: With low melt viscosity (MVR 25 cm³/10min), Hostaform MT SlideX 2404 is designed for fast cycling and thin walled parts. Adjust cycle parameters to maximize throughput while maintaining part quality.

  • Drying: Drying is recommended for this medical grade material to achieve optimal performance and part quality. If material has come into contact with moisture through improper storage or handling, drying is necessary to prevent splay and odor.

  • Medical Grade Purity: Strictly prevent cross‑contamination with other polymer grades or non-medical materials. Contamination will compromise the medical compliance and biocompatibility of the material.

  • Thermal Degradation Risk: POM‑based material can decompose under excessive heat and release formaldehyde vapors. Guarantee sufficient ventilation; avoid overly long barrel residence times.

  • Regrind / Recycled Material Notice: We do not recommend adding regrind for this medical grade specialty material. Reprocessing may compromise the biocompatibility, tribological properties, and medical compliance. If regrind usage is mandatory, keep percentage below 10% and complete pre‑validation testing first.

  • Storage Guidance: Store pellets in cool, dry conditions; keep sealed in original factory packaging whenever possible to maintain low residual monomer content.

Related Products

Technical Documents

We provide complete supporting documentation for material selection and compliance verification.

Document Type Description & Source
Celanese Official TDS Complete physical, thermal, mechanical and processing properties of Hostaform MT SlideX 2404, issued by Celanese original.
Celanese Official SDS GHS‑compliant chemical safety documentation, original Celanese document.
Celanese Distributor Authorization Certificate Proof of our authorized‑distributor qualification for Celanese Hostaform series, available upon request.
ISO 10993 Biocompatibility Report Biocompatibility certification documentation for medical applications.
USP Class VI Certification USP Class VI biocompatibility compliance documentation.
FDA Compliance Declaration FDA 21 CFR 177.2470 compliance statement; Drug Master File (DMF 11559) and Device Master File (MAF 1079) listings.
BfR Food Contact Compliance Food contact approval documentation.
ISCC Plus Certification (ECO‑B) Sustainability certification for ECO‑B variant.
RoHS / REACH Compliance Declarations Available upon customer request.
Processing & Molding Guide Detailed molding operation guidance for medical grade tribological POM.

Request any document above by:

  • Email: ruiqingchem@gmail.com

  • Online form: Our contact page

We reply within one working business day. Please clearly state material grade (Hostaform MT SlideX 2404) and document type you require.

External Reference

For further authoritative information, please visit the official Celanese Hostaform product portal and download the latest datasheet for Hostaform MT SlideX 2404.

Major technical standards referenced inside this article:

  • ISO 1043-1 / ISO 11469 – Resin identification and part marking

  • ISO 1183 – Density measurement

  • ISO 527-1/-2 – Tensile properties

  • ISO 178 – Flexural properties

  • ISO 179/1eU / 1eA – Impact resistance

  • ISO 75-1/-2 – Heat deflection temperature

  • ISO 1133 – Melt volume-flow rate

  • ISO 11357-1/-3 – Melting temperature

  • ISO 294-4, 2577 – Mold shrinkage

  • ISO 11359-1/-2 – Coefficient of linear thermal expansion

  • ISO 2039-1 – Ball indentation hardness

  • ISO 62 – Water/humidity absorption

  • ISO 10993 – Biological evaluation of medical devices

  • USP Class VI – United States Pharmacopeia biocompatibility standard

  • FDA 21 CFR 177.2470 – U.S. Food and Drug Administration food contact regulation

Our technical team can supply relevant standard excerpts for your engineering reference.

FAQ

Q1: What is Hostaform MT SlideX 2404 and what is it used for?
A: Hostaform MT SlideX 2404 is a low melt viscosity, tribologically modified POM‑C (Polyoxymethylene Copolymer) injection molding grade developed by Celanese. It is designed for fast cycling and thin walled parts with tribological modification for use in demanding applications that require prevention of audible noise caused by stick-slip phenomenon and low friction and wear against plastics and metals. It is widely used in medical and healthcare applications including drug delivery devices, inhalers, insulin injection pens, surgical instruments, and portable diagnostic medical equipment, as well as automotive interior components, electrical & electronics, industrial machinery, and consumer goods.

Q2: What is the difference between Hostaform MT SlideX 1203 and 2404?
A: MT SlideX 1203 is a standard flow grade (MVR 13 cm³/10min) with medium flowability. MT SlideX 2404 is a high flow/low melt viscosity grade (MVR 25 cm³/10min) designed for fast cycling and thin walled parts. Choose 2404 when exceptional flowability, thin wall capability, and fast cycle times are required.

Q3: What makes this grade different from standard POM grades?
A: Hostaform MT SlideX 2404 features proprietary SlideX tribological modification for excellent low friction and low wear. It is a medical grade with full ISO 10993 and USP Class VI biocompatibility certification, contains low residual monomers and no animal‑derived constituents, and is FDA 21 CFR compliant with DMF and MAF listings. It also provides effective stick‑slip noise prevention for quiet operation and has low melt viscosity for fast cycling.

Q4: What are the key mechanical properties?
A: Tensile modulus 2550 MPa, yield stress 55 MPa, yield strain 7%, nominal strain at break 50%, Charpy notched impact strength 5.5 kJ/m² (23°C and -30°C), Charpy impact strength 160 kJ/m² (23°C) / 150 kJ/m² (-30°C), ball indentation hardness 130 MPa, melting temperature 166°C, and heat deflection temperature 90°C at 1.8 MPa

Q5: What is the MVR?
A: Melt‑volume‑flow‑rate equals 25 cm³/10min measured under 190°C / 2.16 kg test condition.

Q6: What sterilization methods are compatible with this material?
A: Hostaform MT SlideX 2404 is compatible with Ethylene Oxide (EtO) sterilization and steam sterilization (autoclaving), making it suitable for medical applications requiring sterilization.

Q7: What medical certifications does this material hold?
A: This material complies with ISO 10993 (biological evaluation of medical devices) and USP Class VI biocompatibility standards. It is FDA 21 CFR compliant and listed in the Drug Master File (DMF 11559) and Device Master File (MAF 1079).

Q8: What is the ECO‑B variant?
A: ECO‑B is a sustainable version of Hostaform MT SlideX 2404 with the same properties and performance. Using a mass‑balance approach, biogenic feedstocks offset fossil‑based raw materials and decrease greenhouse gas emissions. The process is audited and certified according to ISCC Plus.

Q9: Is drying required before processing?
A: Drying is recommended for this medical grade material. Recommended drying: 100°C for 3-4 hours. Maximum processing moisture content should be ≤0.15%.

Q10: What are recommended processing‑temperature windows?
A: Zone 1 temperature: 170-175°C. Optimum mold temperature: 80-120°C.

Q11: What regions is this material available in?
A: Hostaform MT SlideX 2404 is available in North America, Europe, South and Central America, and Near East/Africa.

Q12: Can I buy this material and what is lead‑time?
A: Yes. Submit your inquiry via our quick inquiry form or email ruiqingchem@gmail.com, specify quantity, application and delivery address. Regular orders 1‑5 tons ship within 7‑10 working days after payment confirmation. Large‑volume or urgent orders can be negotiated separately.

Q13: What are limitations?
A: POM‑C does not resist strong mineral acids, powerful oxidizing agents, or continuous exposure to hot water >80°C. Consult our technical team for chemical‑compatibility data for your exact working environment.

CTA (Call to Action)

Ready to order Hostaform MT SlideX 2404?

To get precise quotation and professional technical support, please share these details:

  • Required quantity (kg or tons)

  • Destination port or delivery address

  • Target application and part brief (medical device, thin wall parts, drug delivery, etc.)

  • Core performance requirements (fast cycling, low friction, biocompatibility, sterilization method, etc.)

  • ECO‑B preference (standard or sustainable ECO‑B variant)

  • Document requirement (TDS, SDS, ISO 10993 report, USP Class VI certification, FDA compliance, etc.)

Sample Policy:

  • Samples are for laboratory validation tests only, not for mass‑production use.

  • Buyer bears international sample‑shipping freight.

  • If bulk‑material performance deviates from sample reference, Celanese official TDS serves as authoritative benchmark.

Take action now:

  • Send Inquiry – Use our quick inquiry form

  • Email Us – ruiqingchem@gmail.com

  • Live Chat – Click bottom‑right chat widget to speak directly with our team

After-Sales Support

Service Details
Quality Inspection Period All quality‑related claims must be submitted within 7 working‑days after delivery, supported by test data and photographic evidence.
Return / Exchange Policy Confirmed material defects caused by our side trigger replacement or refund. Terms and conditions apply. Please check our full Terms & Conditions.
Logistics Damage Report shipping damage directly to carrier immediately upon goods receipt. We assist with claim‑document preparation.
Technical Support Remote technical guidance available. On‑site molding troubleshooting service can be arranged upon special request.
Export Documentation We supply standard export documents: commercial invoice, packing list, bill of lading, COA. Additional compliance certificates (e.g., ISO 10993 reports, USP Class VI certifications, FDA compliance documents) can be provided on request.

Disclaimer

DISCLAIMER: All technical data is referenced from original Celanese typical values for Hostaform MT SlideX 2404. Our company acts as authorized distributor/trader rather than original manufacturer. Final component performance depends on part geometry, processing setup and end‑use environment. Buyers shall independently validate material suitability for individual applications, particularly for medical device applications where regulatory compliance and biocompatibility testing are required. Our firm bears no liability for finished‑part failure caused by improper design or improper processing. Always reference latest Celanese official TDS of Hostaform MT SlideX 2404 as definitive specification.

Technical Documents

Download technical data sheets, safety data sheets and certificates for this material.

TDS Files

Technical document available for review or download.

0 Files
No TDS file uploaded yet.

MSDS Files

Technical document available for review or download.

0 Files
No MSDS file uploaded yet.