VESTAMID LX9057 OR E20081 PA12 FR Halogen-Free Cable Resin

基础信息

品名
VESTAMID LX9057 OR E20081
牌号
LX9057 OR E20081
厂商
Evonik
材料类型
Unfilled Polyamide 12 (PA12)
产品形态
Pellets / Granules (Injection Molding Grade)
特点
Halogen-free flame retardant, UL94 V-2, heat stabilized, low viscosity, high toughness, low water absorption, dimensional stability, low coefficient of friction, electrical insulation and general chemical resistance

描述

VESTAMID LX9057 OR E20081 is a low-viscosity, self-extinguishing polyamide 12 compound from Evonik Operations GmbH containing an efficient halogen-free flame-retardant system.

The grade is designed especially for the electrical, electronics and cable industries, where flame behavior, electrical insulation, dimensional stability, toughness and processing consistency are important at the same time.

Current grade-specific material information classifies VESTAMID LX9057 OR E20081 as PA12 FR(30+40). It is heat stabilized, halogen-free and suitable for both injection molding and wire extrusion coating.

Flame behavior is one of the grade’s defining characteristics. The current Material Data Center datasheet reports V-2 at 0.8 mm and V-2 at 1.5 mm, with a Yellow Card available. The current UL certification for LX9057 OR E20081 also lists V-2 down to 0.40 mm for the orange grade. This provides useful qualification information for thin-wall electrical and cable-related components.

The PA12 base contributes low moisture sensitivity. Published water absorption is approximately 1.8% and humidity absorption approximately 0.8%. Because PA12 absorbs much less water than many shorter-chain polyamides, molded or extruded parts show good dimensional stability as ambient humidity changes.

Mechanical performance remains strong despite the flame-retardant package. Dry tensile modulus is approximately 1,200 MPa, while conditioned modulus is approximately 820 MPa. Dry yield stress is approximately 37 MPa, and nominal strain at break remains above 50% in both dry and conditioned states.

Impact behavior is also useful. Dry unnotched Charpy impact strength at 23°C is approximately 130 kJ/m², while the current -30°C values are approximately 69 kJ/m² dry and 122 kJ/m² conditioned.

The orange E20081 formulation also retains important electrical-insulation performance. Current data lists a dry volume resistivity of approximately 7.4 × 10¹¹ Ω·m, electric strength of approximately 35 kV/mm, and CTI 600.

The material is supplied as cylindrical granules in moisture-proof packaging and has a shelf life of at least two years in original undamaged packaging stored dry at temperatures not exceeding 30°C.

For more PA12 materials, visit our PA12 Polyamide 12 Product Category →.

For official manufacturer information on PA12 cable materials, visit the Evonik VESTAMID Cable Sheathing Guide →.

Key Features of VESTAMID LX9057 OR E20081

Feature Benefit
Halogen-Free Flame Retardant Supports modern electrical and cable material concepts
UL94 V-2 Current UL record lists V-2 down to 0.40 mm for the orange grade
Low Viscosity Supports good flow in molding and wire-coating processes
Heat Stabilized Supports reliable processing and thermal durability
High Toughness Useful for cable and electrical parts exposed to impact
Low Water Absorption Helps reduce humidity-driven dimensional change
Dimensional Stability Important for connectors, cable parts and molded components
Electrical Insulation 35 kV/mm dry electric strength and CTI 600
Low Coefficient of Friction Useful for moving, sliding or cable-contact surfaces
General Chemical Resistance Supports many electrical and industrial environments
Injection Moldable Suitable for molded electrical/electronic components
Wire Extrusion Coating Suitable for conductor and cable insulation/protection

The combination of low viscosity, electrical insulation and halogen-free flame retardancy is the central advantage of VESTAMID LX9057 OR E20081.

Typical Applications for VESTAMID LX9057 OR E20081

VESTAMID LX9057 OR E20081 is primarily intended for electrical and cable applications.

Application Area Typical Use
Wire Extrusion Coating PA12 insulation or protective covering on wires and conductors
Cable Components Flame-retardant, halogen-free cable parts
Electrical Connectors Tough injection-molded components requiring flame performance
Electronic Components Small molded parts with electrical-insulation requirements
Cable Protection Parts PA12 components exposed to abrasion and repeated movement
Insulating Components Molded parts requiring dimensional stability and dielectric strength
Thin-Wall Electrical Parts Applications benefiting from UL94 V-2 performance at low thickness
Technical Injection-Molded Parts Flame-retardant engineering components

The strongest product positioning is electrical/electronic parts and wire extrusion coating.

Typical Properties of VESTAMID LX9057 OR E20081

Physical & Rheological Properties

Property Typical Value Test Method
Density 1.08 g/cm³ ISO 1183
Water Absorption 1.8% Similar to ISO 62
Humidity Absorption 0.8% Similar to ISO 62
MVR 45 cm³/10 min ISO 1133
MVR Test Condition 220°C / 2.16 kg
Molding Shrinkage – Parallel 0.9% ISO 294-4 / 2577
Molding Shrinkage – Normal 1.0% ISO 294-4 / 2577
Shore D Hardness 69 ISO 7619-1
Material Classification PA12 FR(30+40) Current grade designation

The MVR of 45 cm³/10 min at 220°C / 2.16 kg confirms the low-viscosity positioning of VESTAMID LX9057 OR E20081.

Mechanical Properties

Property Dry / Conditioned Test Method
Tensile Modulus 1,200 / 820 MPa ISO 527
Yield Stress 37 / 33 MPa ISO 527
Yield Strain 12 / 17% ISO 527
Nominal Strain at Break >50 / >50% ISO 527
Charpy Impact Strength, 23°C 130 / No Break kJ/m² ISO 179/1eU
Charpy Impact Strength, -30°C 69 / 122 kJ/m² ISO 179/1eU
Charpy Notched Impact, 23°C 3 / 7 kJ/m² ISO 179/1eA
Charpy Notched Impact, -30°C 3 / 2 kJ/m² ISO 179/1eA

These values show that VESTAMID LX9057 OR E20081 remains ductile and impact resistant despite containing a flame-retardant system.

Thermal & Flammability Properties

Property Typical Value Test Method
Melting Temperature 176°C ISO 11357-1/-3
Glass Transition Temperature 40°C ISO 11357-1/-2
HDT @ 1.80 MPa 55°C ISO 75-1/-2
HDT @ 0.45 MPa 130°C ISO 75-1/-2
Vicat Softening Temperature B 136°C ISO 306
Flammability @ 1.5 mm V-2 IEC 60695-11-10
Flammability @ 0.8 mm V-2 IEC 60695-11-10
UL Certification V-2 down to 0.40 mm UL E100211
Yellow Card Available Manufacturer / UL data

The current grade-specific dataset and current UL record should take precedence over older generic LX9057 family brochures where a different flame class may be shown.

Electrical Properties

Property Dry / Conditioned Test Method
Relative Permittivity, 100 Hz 4.5 / 7.5 IEC 62631-2-1
Relative Permittivity, 1 MHz 3.2 / 3.5 IEC 62631-2-1
Dissipation Factor, 100 Hz 920 / 1920 × 10⁻⁴ IEC 62631-2-1
Dissipation Factor, 1 MHz — / 537 × 10⁻⁴ IEC 62631-2-1
Volume Resistivity 7.4 × 10¹¹ / 9.3 × 10⁹ Ω·m IEC 62631-3-1
Electric Strength 35 / 36 kV/mm IEC 60243-1
Comparative Tracking Index 600 IEC 60112

The combination of CTI 600 and approximately 35–36 kV/mm electric strength makes VESTAMID LX9057 OR E20081 particularly relevant for electrical and electronic applications.

Why Choose VESTAMID LX9057 OR E20081?

The primary reason to choose VESTAMID LX9057 OR E20081 is the balance of halogen-free flame retardancy, electrical insulation and PA12 toughness.

Many flame-retardant engineering plastics become relatively stiff or brittle. LX9057 OR E20081 retains more than 50% nominal strain at break and strong impact performance, making it suitable for parts that must survive assembly, vibration and handling.

Low moisture uptake is another important advantage. Electrical components can suffer dimensional drift when a polymer absorbs water. PA12 helps reduce this problem compared with more hygroscopic polyamides.

The material’s low viscosity also supports processing. In injection molding, good flow can assist filling of thin-wall features. In wire extrusion coating, it helps the melt distribute around the conductor or cable substrate.

Electrical performance is particularly strong for this application class. CTI 600 supports tracking resistance, while 35–36 kV/mm electric strength provides useful dielectric capability.

Finally, the orange E20081 color provides a ready-colored formulation for applications where orange identification is required.

Processing Guidelines for VESTAMID LX9057 OR E20081

VESTAMID LX9057 OR E20081 can be processed by injection molding and coating / wire extrusion coating.

Temperature control is especially important because of the flame-retardant package.

Processing Parameter Published Guidance
Recommended Melt Temperature 200–220°C
Maximum Melt Temperature Do not exceed 240°C
ISO Test Melt Temperature 220°C
ISO Test Mold Temperature 80°C
ISO Test Injection Velocity 200 mm/s
MVR Test Condition 220°C / 2.16 kg
Primary Processes Injection Molding, Coating / Wire Extrusion Coating
Packaging Moisture-proof bags
Shelf Life At least 2 years at ≤30°C in original undamaged packaging

Evonik specifically states that the melt temperature should not exceed 240°C because the compound contains flame retardant. The recommended melt-temperature range is 200–220°C.

For wire extrusion coating, the exact barrel profile, head temperature, die temperature, conductor preheating, line speed and coating thickness should be optimized for the actual equipment and cable construction.

For injection molding, the grade-specific standardized test condition of 220°C melt / 80°C mold / 200 mm/s injection velocity is a useful technical reference.

VESTAMID LX9057 OR E20081 vs. VESTAMID LX9057 GN E60044

Feature VESTAMID LX9057 OR E20081 VESTAMID LX9057 GN E60044
Base Polymer PA12 FR(30+40) PA12 FR(30+40)
Color Orange Green
Viscosity Low Low
Flame Retardant Halogen-Free Halogen-Free
Current Flame Class V-2 V-2
MVR 45 cm³/10 min @ 220°C / 2.16 kg Use exact GN grade TDS
Tensile Modulus 1,200 / 820 MPa Use exact GN grade TDS
Primary Applications Electrical parts, cable, wire coating Electrical parts, cable, wire coating
Recommended Melt Range 200–220°C 200–220°C
Main Selection Difference Orange E20081 color and exact OR property set Green E60044 color and exact GN property set

The two grades belong to the same LX9057 flame-retardant PA12 family, but pigmentation can affect property values. For qualification, the exact color-grade TDS should always be used.

Choose VESTAMID LX9057 OR E20081 when the orange E20081 formulation is specified.

Choose VESTAMID LX9057 GN E60044 when the green E60044 formulation is required.

Related Products

VESTAMID LX9057 GN E60044 – Green halogen-free flame-retardant PA12 for electrical and cable applications.

VESTAMID LX9104 – Flame-retardant PA12 cable material for selected higher flame-performance cable systems.

VESTAMID L2170 OR E20005 – Orange PA12 cable-sheathing grade where LX9057 flame-retardant performance is not required.

View More PA12 Polyamide 12 Materials →

Technical Documents for VESTAMID LX9057 OR E20081

Document Type Description
TDS Grade-specific physical, mechanical, thermal, electrical and rheological data
SDS Safety Data Sheet
COA Batch-specific Certificate of Analysis where available
UL Yellow Card Current UL flame and electrical certification data
Cable Processing Information Wire extrusion coating guidance
Compliance Documentation Electrical, electronic and cable-related documents subject to availability

Need technical documents for VESTAMID LX9057 OR E20081?

📧 Email: ruiqingchem@gmail.com
📝 Online form: Contact Us →

Please state VESTAMID LX9057 OR E20081 and the required document type when submitting your inquiry.

FAQ About VESTAMID LX9057 OR E20081

Q1: What is VESTAMID LX9057 OR E20081?

VESTAMID LX9057 OR E20081 is an orange, low-viscosity, heat-stabilized, halogen-free flame-retardant PA12 from Evonik for electrical components and wire extrusion coating.

Q2: Is VESTAMID LX9057 OR E20081 halogen-free?

Yes. Evonik explicitly describes this grade as containing an efficient halogen-free flame-retardant system.

Q3: What UL94 rating does VESTAMID LX9057 OR E20081 have?

The current grade-specific datasheet reports V-2 at 0.8 mm and 1.5 mm. The current UL certification record lists V-2 down to 0.40 mm for the orange grade.

Q4: What is the MVR of VESTAMID LX9057 OR E20081?

The typical MVR is approximately 45 cm³/10 min at 220°C / 2.16 kg.

Q5: What is the density of VESTAMID LX9057 OR E20081?

The typical density is approximately 1.08 g/cm³ according to ISO 1183.

Q6: What is the tensile modulus?

The typical tensile modulus is approximately 1,200 MPa dry and 820 MPa conditioned.

Q7: What electrical properties does the grade offer?

Typical dry values include 7.4 × 10¹¹ Ω·m volume resistivity, 35 kV/mm electric strength and CTI 600.

Q8: What processing temperature is recommended?

Evonik recommends a melt temperature of approximately 200–220°C and states that the melt should not exceed 240°C.

Q9: Can VESTAMID LX9057 OR E20081 be used for wire extrusion coating?

Yes. Wire extrusion coating is explicitly identified as a processing/application route for this grade.

Q10: Can you provide VESTAMID LX9057 OR E20081 TDS, SDS and UL documentation?

Yes. Please request the required technical documents through our Contact Page → or email ruiqingchem@gmail.com.

Request VESTAMID LX9057 OR E20081 Price & Technical Support

For pricing, availability, technical documents or grade-selection support for VESTAMID LX9057 OR E20081, please provide:

  • Required quantity
  • Destination country or port
  • Injection-molded electrical part or wire-coating application
  • Required UL94 rating and minimum thickness
  • Cable or conductor dimensions
  • Required wall / insulation thickness
  • Operating temperature
  • Electrical insulation requirement
  • CTI or dielectric-strength requirement
  • Chemical exposure
  • Color requirement
  • Injection-molding or wire-extrusion equipment information
  • TDS, SDS, COA or UL documentation requirements
  • Sample requirement, if applicable

📧 Email: ruiqingchem@gmail.com
📝 Send Inquiry →

Technical Documents

Download technical data sheets, safety data sheets and certificates for this material.

TDS Files

Technical document available for review or download.

0 Files
No TDS file uploaded yet.

MSDS Files

Technical document available for review or download.

0 Files
No MSDS file uploaded yet.