描述
VESTAMID L2170 OR E20005 is a high-viscosity, heat- and light-stabilized polyamide 12 resin manufactured by Evonik Operations GmbH. It was developed especially for extrusion of cable sheathings and can also be used for semi-finished products such as tubes, rods, sheets and profiles.
The material is supplied in an orange formulation and is identified in Evonik product literature as PA12, EHL, 22-010. Compared with general-purpose PA12 grades, VESTAMID L2170 OR E20005 places stronger emphasis on light and weathering resistance for demanding outdoor cable applications.
One of its most important advantages is the low coefficient of friction associated with semi-crystalline PA12. This low sliding friction helps reduce resistance when cables are pulled through ducts, conduits or protective channels.
The material also has a tough and smooth surface. Evonik specifically describes cable sheathing made from the L2170 family as helping protect directly buried cables against attack by termites and rodents. Official Evonik cable literature also identifies L2170 as a PA12 grade used for underground cable protection where toughness, weathering resistance and resistance to pests are important.
Low water absorption is another key characteristic. Published data for VESTAMID L2170 OR E20005 gives approximately 1.6% water absorption and 0.8% humidity absorption. As a result, the material retains good dimensional stability when ambient humidity changes.
The grade also combines high toughness with good chemical resistance. These properties are important for outdoor cable systems, underground installation and industrial extrusion applications where the polymer may contact water, oils, fuels or other environmental media.
In addition to wire and cable extrusion, current product data lists injection molding, pipe/tube extrusion, profile extrusion and sheet extrusion as possible processing methods.
Explore additional grades in our PA12 Polyamide 12 Product Category →.
For official manufacturer information about cable applications, visit the Evonik VESTAMID and VESTODUR Cable Sheathing Guide →.
Key Features of VESTAMID L2170 OR E20005
| Feature | Benefit |
|---|---|
| High Viscosity | Provides melt strength for cable sheathing, tube, sheet and profile extrusion |
| Heat Stabilized | Supports demanding processing and service environments |
| Highly Light Stabilized | Designed for strong weathering and UV-exposure requirements |
| Cable Sheathing Grade | Developed specifically for protective outer cable layers |
| High Toughness | Helps protect cables against impact and mechanical damage |
| Low Coefficient of Friction | Eases cable installation through ducts and conduits |
| Low Water Absorption | Helps preserve dimensions under changing humidity |
| Good Chemical Resistance | Suitable for demanding outdoor and industrial environments |
| Tribological Performance | Useful where low sliding friction and wear behavior are important |
| Termite / Rodent Protection | Tough, smooth PA12 sheathing helps resist pest-related cable damage |
| Orange Color | Supplied as orange grade E20005 |
| Broad Extrusion Capability | Suitable for cable, tube, profile and sheet extrusion |
The combination of light stabilization, toughness and low friction is what makes VESTAMID L2170 OR E20005 particularly well suited to cable-protection applications.
Typical Applications for VESTAMID L2170 OR E20005
VESTAMID L2170 OR E20005 is primarily intended for cable-protection and extrusion applications.
| Application Area | Typical Use |
|---|---|
| Cable Sheathing | Protective outer layers for electrical and communication cables |
| Underground Cables | Durable PA12 cladding for direct-buried cable systems |
| Telecommunication Cables | Protective sheathing requiring toughness and weather resistance |
| Optical-Fiber Cable Systems | External protective cable layers and related extrusion applications |
| Tubes | Extruded PA12 tubes requiring toughness and dimensional stability |
| Rods | Semi-finished PA12 rod stock |
| Sheets | Extruded sheet applications |
| Profiles | Technical profiles requiring weathering and chemical resistance |
Evonik’s cable-sheathing literature specifically identifies VESTAMID L2170 OR E20005 and the L2170 family for applications where weathering resistance and protection against termites or rodents are important.
The grade can therefore be particularly useful in hot, humid or pest-prone environments where standard polyethylene cable sheathing may not offer sufficient mechanical protection.
Typical Properties of VESTAMID L2170 OR E20005
Physical & Rheological Properties
| Property | Typical Value | Test Method |
|---|---|---|
| Density | 1.02 g/cm³ | ISO 1183 |
| Water Absorption | 1.6% | Similar to ISO 62 |
| Humidity Absorption | 0.8% | Similar to ISO 62 |
| Melt Volume-Flow Rate (MVR) | 3.4 cm³/10 min | ISO 1133 |
| MVR Test Condition | 230°C / 2.16 kg | — |
| Molding Shrinkage – Parallel | 0.7% | ISO 294-4 / 2577 |
| Molding Shrinkage – Normal | 1.3% | ISO 294-4 / 2577 |
| Shore D Hardness | 72 | ISO 7619-1 |
The relatively low MVR confirms the high-viscosity character of VESTAMID L2170 OR E20005, which supports stable extrusion and good melt strength.
Mechanical Properties
| Property | Typical Value | Test Method |
|---|---|---|
| Tensile Modulus | 1,650 MPa | ISO 527 |
| Yield Stress | 46 MPa | ISO 527 |
| Yield Strain | 4% | ISO 527 |
| Nominal Strain at Break | >50% | ISO 527 |
| Charpy Impact Strength, 23°C | No Break | ISO 179/1eU |
| Charpy Impact Strength, -30°C | No Break | ISO 179/1eU |
| Charpy Notched Impact, 23°C | 6 kJ/m² | ISO 179/1eA |
| Charpy Notched Impact, -30°C | 7 kJ/m² | ISO 179/1eA |
The no-break result in unnotched Charpy testing at both room temperature and -30°C demonstrates the toughness required for protective cable sheathing.
Thermal & Flammability Properties
| Property | Typical Value | Test Method |
|---|---|---|
| Melting Temperature | 178°C | ISO 11357-1/-3 |
| Glass Transition Temperature | 44°C | ISO 11357-1/-2 |
| HDT @ 1.80 MPa | 50°C | ISO 75-1/-2 |
| HDT @ 0.45 MPa | 110°C | ISO 75-1/-2 |
| Vicat Softening Temperature B | 148°C | ISO 306 |
| Flammability @ 1.5 mm | HB | IEC 60695-11-10 |
| Flammability @ 3.0 mm | HB | IEC 60695-11-10 |
| Oxygen Index (LOI) | 24% | ISO 4589-1/-2 |
| UL Yellow Card | Available | — |
The grade is not positioned as a flame-retardant PA12. Its main cable value is weathering, abrasion, impact and chemical performance rather than a V-0 flame-retardant classification.
Electrical Properties
| Property | Typical Value | Test Method |
|---|---|---|
| Relative Permittivity, 100 Hz | 4.1 | IEC 62631-2-1 |
| Relative Permittivity, 1 MHz | 3.0 | IEC 62631-2-1 |
| Dissipation Factor, 100 Hz | 700 × 10⁻⁴ | IEC 62631-2-1 |
| Dissipation Factor, 1 MHz | 353 × 10⁻⁴ | IEC 62631-2-1 |
| Volume Resistivity | 9.2 × 10¹² Ω·m | IEC 62631-3-1 |
| Comparative Tracking Index (CTI) | 600 | IEC 60112 |
These values confirm that VESTAMID L2170 OR E20005 is electrically insulating and suitable for protective cable applications.
Why Choose VESTAMID L2170 OR E20005?
The main reason to choose VESTAMID L2170 OR E20005 is its combination of cable-sheathing processability, weathering resistance and mechanical protection.
Outdoor and underground cables face several simultaneous challenges. They can be exposed to moisture, temperature changes, sunlight, abrasion and chemical contamination. In some regions, termites and rodents can also damage cable jackets.
Evonik developed the L2170 family specifically for this environment. The material is highly light stabilized, and official VESTAMID literature describes L2170 as a UV-stable and termite-resistant cable-sheathing grade.
The PA12 surface also has low friction. This reduces drag when the cable is installed in ducts and can make long cable pulls easier compared with higher-friction materials.
The high viscosity helps maintain stable cable-jacket geometry during extrusion, while the high toughness helps resist mechanical damage after installation.
Low water absorption further supports dimensional stability, and broad chemical resistance helps the sheathing tolerate demanding outdoor and underground environments.
For customers seeking a high-viscosity PA12 specifically optimized around cable-protection requirements, VESTAMID L2170 OR E20005 is therefore more targeted than a general tube-extrusion PA12.
Processing Guidelines for VESTAMID L2170 OR E20005
VESTAMID L2170 OR E20005 is listed for wire/cable extrusion, pipe/tube extrusion, profile extrusion, sheet extrusion and injection molding.
The current product data provides the following ISO test-specimen conditions:
| Processing Item | Published Condition |
|---|---|
| Primary Processing | Wire / Cable Extrusion |
| Other Processes | Pipe / Tube, Profile and Sheet Extrusion; Injection Molding |
| ISO Test Melt Temperature | 240°C |
| ISO Test Mold Temperature | 60°C |
| ISO Test Injection Velocity | 200 mm/s |
| Supply Condition | Cylindrical granules in moisture-proof packaging |
| Storage | Dry storage at ≤30°C in original undamaged packaging |
These ISO molding values are test-specimen conditions and should not be treated as a universal cable-extrusion temperature profile.
For cable extrusion, the barrel-temperature profile, die temperature, line speed, draw-down ratio and cooling system should be optimized for the actual cable diameter, jacket thickness and production line.
Evonik states that VESTAMID compounds are delivered dry in moisture-proof packaging. Material from intact packaging does not normally require additional drying before processing.
For opened or damaged packaging, Evonik’s cable-processing guide recommends drying VESTAMID in a desiccant dryer at approximately 90–100°C for a minimum of two hours. A dehumidifying hopper dryer operating around 60–80°C may also be used during processing.
The moisture content of VESTAMID should remain low during extrusion because excess moisture can reduce melt quality and surface appearance.
Inside original and undamaged packaging, VESTAMID L2170 OR E20005 has a published shelf life of at least two years when stored in dry rooms at temperatures not exceeding 30°C.
VESTAMID L2170 OR E20005 vs. VESTAMID L2140 BK 9.7504
| Feature | VESTAMID L2170 OR E20005 | VESTAMID L2140 BK 9.7504 |
|---|---|---|
| Base Polymer | PA12 | PA12 |
| Viscosity | High | High |
| Color | Orange | Black |
| Light Stabilization | Highly light stabilized | Light stabilized |
| Primary Positioning | Cable sheathing and outdoor cable protection | Fuel lines, tubes, cable sheathing and semi-finished products |
| Termite / Rodent Protection | Specifically highlighted for L2170 cable sheathing | Not the primary product positioning |
| Low Friction | Yes | Yes |
| Main Selection Reason | UV-stable, pest-resistant cable protection | General high-viscosity PA12 extrusion |
Choose VESTAMID L2170 OR E20005 when the main requirement is outdoor or underground cable sheathing with strong weathering, low-friction and pest-protection performance.
Choose VESTAMID L2140 BK 9.7504 when the application is more focused on fuel-line tubing, general high-viscosity PA12 extrusion or black cable sheathing.
Related Products
VESTAMID L2140 BK 9.7504 – High-viscosity black PA12 for fuel lines, cable sheathing and extrusion.
VESTAMID L1940 BK 9.7504 – Medium-viscosity PA12 for cable, fiber-optic and injection-molding applications.
VESTAMID L1670 NC – Low-viscosity PA12 for thin wire insulation and cable extrusion.
View More PA12 Polyamide 12 Materials →
Technical Documents for VESTAMID L2170 OR E20005
| Document Type | Description |
|---|---|
| TDS | Technical Data Sheet with physical, mechanical, thermal and electrical properties |
| SDS | Safety Data Sheet |
| COA | Batch-specific Certificate of Analysis where available |
| Cable Processing Guide | Evonik guidance for VESTAMID cable extrusion and handling |
| UL Information | Relevant UL Yellow Card / flammability information |
| Compliance Documents | Relevant electrical, cable and regulatory documentation subject to availability |
Need technical documents for VESTAMID L2170 OR E20005?
📧 Email: ruiqingchem@gmail.com
📝 Online form: Contact Us →
Please state VESTAMID L2170 OR E20005 and the required document type when submitting your inquiry.
FAQ About VESTAMID L2170 OR E20005
Q1: What is VESTAMID L2170 OR E20005?
VESTAMID L2170 OR E20005 is an orange, high-viscosity, heat- and highly light-stabilized PA12 resin from Evonik developed especially for cable-sheathing extrusion.
Q2: What are the main applications of VESTAMID L2170 OR E20005?
Typical applications include cable sheathing, underground cable protection, telecommunication cables, tubes, rods, sheets and technical profiles.
Q3: Is VESTAMID L2170 OR E20005 UV stabilized?
Yes. Evonik literature identifies the L2170 family as highly light stabilized and specifically positions it for UV-stable cable sheathing.
Q4: What is the density of VESTAMID L2170 OR E20005?
The typical density is approximately 1.02 g/cm³ according to ISO 1183.
Q5: What is the MVR of VESTAMID L2170 OR E20005?
The typical MVR is approximately 3.4 cm³/10 min at 230°C / 2.16 kg according to ISO 1133.
Q6: What is the tensile modulus of VESTAMID L2170 OR E20005?
The typical tensile modulus is approximately 1,650 MPa according to ISO 527.
Q7: What is the melting temperature of VESTAMID L2170 OR E20005?
The typical melting temperature is approximately 178°C according to ISO 11357.
Q8: Can VESTAMID L2170 OR E20005 help protect underground cables from termites and rodents?
Yes. Evonik specifically states that the tough, smooth surface of L2170 PA12 cable sheathing helps protect directly buried cables against termite and rodent attack.
Q9: Is VESTAMID L2170 OR E20005 flame retardant?
It is classified HB at the published test thicknesses and has an oxygen index of approximately 24%. It is not positioned as a dedicated V-0 flame-retardant PA12 grade.
Q10: Can you provide VESTAMID L2170 OR E20005 TDS, SDS and COA?
Yes. Please request the required technical documents through our Contact Page → or email ruiqingchem@gmail.com.
Request VESTAMID L2170 OR E20005 Price & Technical Support
For pricing, availability, technical documents or material-selection support for VESTAMID L2170 OR E20005, please provide:
- Required quantity
- Destination country or port
- Cable, tube, sheet or profile application
- Cable outside diameter and sheath thickness
- Outdoor or underground installation conditions
- UV / weathering requirement
- Required electrical or flame-performance standard
- Extrusion-line information
- TDS, SDS, COA or UL document requirements
- Sample requirement, if applicable
📧 Email: ruiqingchem@gmail.com
📝 Send Inquiry →

