Santoprene 281-64MED TPV | Medical Grade USP Class VI 71A TPV

基础信息

品名
Santoprene 281-64MED
牌号
281-64MED
厂商
Celanese Corporation
材料类型
Thermoplastic Vulcanizate (TPV) / Thermoplastic Elastomer (TPE)
产品形态
Pellets
特点
Medical-grade TPV, 71 Shore A hardness, USP Class VI/ISO 10993 biocompatibility testing, FDA DMF support, 432% elongation, 6.1 MPa tensile strength, 2.7 MPa stress at 100% elongation, excellent flex-fatigue resistance, natural color, steam/gamma/ETO sterilization compatibility, injection moldable and extrudable

描述

Santoprene 281-64MED is a natural medical-grade thermoplastic vulcanizate from Celanese designed for medical, healthcare, pharmaceutical and drug-delivery applications.

The grade combines elastomeric flexibility with thermoplastic processability and is specifically included in Celanese’s dedicated Santoprene MED medical-grade portfolio. Celanese describes the material as a soft, colorable specialty TPV with biocompatibility testing corresponding to USP Class VI and ISO 10993.

Current typical properties include:

  • 71 Shore A hardness
  • 0.950 g/cm³ density
  • 6.1 MPa tensile stress at break
  • 432% elongation at break
  • 2.7 MPa tensile stress at 100% elongation
  • 23.7% compression set at 23°C / 168 h
  • 27% compression set at 70°C / 24 h
  • 34% compression set at 125°C / 24 h
  • 44% compression set at 125°C / 70 h

This balance makes Santoprene 281-64MED useful for medical components that require more firmness than very soft elastomers while still needing substantial flexibility and elastic recovery.

Celanese also specifically promotes Santoprene 281-64MED for peristaltic pump tubing, where the material’s resiliency, flex-fatigue performance, elasticity and sterilizability are important.

The grade can be processed on conventional thermoplastic equipment by injection molding and extrusion, and current Celanese data also lists multi-injection molding, sheet extrusion and coextrusion.

For more TPV products, visit our TPV Thermoplastic Vulcanizates Product Category →.

For the current Santoprene portfolio, see the Official Celanese Santoprene & Geolast Product Finder →.

Key Features of Santoprene 281-64MED

Feature Engineering Benefit
71 Shore A Hardness Provides a medium-soft medical elastomer with useful mechanical support
Medical-Grade TPV Developed specifically for healthcare and medical applications
USP Class VI Testing Supports medical biocompatibility evaluation
ISO 10993 Testing Supports biological evaluation requirements
FDA Drug Master File Regulatory documentation available for the Santoprene 181/281 MED family
432% Elongation at Break Provides substantial flexibility and deformation capability
6.1 MPa Tensile Strength Provides useful mechanical durability
2.7 MPa Stress at 100% Elongation Provides a controlled elastomeric response
27% Compression Set @ 70°C / 24 h Provides useful compression-recovery performance
Excellent Flex-Fatigue Resistance Important for repeatedly flexed medical components
Steam Sterilizable Supports selected steam-sterilized medical applications
Gamma Sterilizable Supports selected gamma-sterilized applications
ETO Sterilizable Supports ethylene-oxide sterilization
Injection Moldable Suitable for complex molded medical components
Extrudable Suitable for tubing and continuous medical profiles
Polyolefin Bonding Suitable for selected overmolding and multi-material designs

Celanese specifically identifies Santoprene 281-64MED as a natural medical grade suitable for steam, gamma and ETO sterilization, with injection and extrusion processing and polyolefin bonding capability.

Typical Applications for Santoprene 281-64MED

Santoprene 281-64MED is especially relevant to medical applications requiring durability, repeated flexing and elastic recovery.

Application Area Typical Use
Peristaltic Pump Tubing Flexible tubing exposed to repeated compression and recovery
Medical Seals Flexible sealing components
Medical Gaskets Elastomeric interfaces requiring repeated compression
Drug-Delivery Devices Flexible functional and sealing components
Syringe Components Flexible seals and interfaces
Pharmaceutical Closures Elastomeric closure components
Medical Tubing Components Flexible tubing, connectors and interfaces
Medical Connectors Flexible connector components
Diagnostic Equipment Molded healthcare components
Pump Components Flexible parts exposed to cyclic deformation
Healthcare Equipment Flexible seals, covers and interfaces
Medical Packaging Components Selected pharmaceutical and healthcare components

Celanese’s dedicated peristaltic-pump material guide describes Santoprene 281-64MED as providing high resiliency, excellent flex fatigue, biocompatibility, sterilizability, low permeation and high elasticity for pump-tubing applications.

Typical Properties of Santoprene 281-64MED

Physical Properties

Property Typical Value Test Method
Density 950 kg/m³ / 0.950 g/cm³ ISO 1183
Shore A Hardness, 15 s 71 ISO 48-4 / ISO 868
Appearance Natural Manufacturer information
Product Form Pellets Manufacturer information
Resin Identification TPV ISO 1043
Part Marking Code >TPV< ISO 11469
Polymer Base Polyolefin-based TPV Manufacturer information

The current Celanese Materials Database sheet revised April 21, 2025 lists 71 Shore A hardness and 950 kg/m³ density.

Mechanical Properties

Property Typical Value Test Method
Tensile Stress at 100% Elongation 2.7 MPa ISO 37
Tensile Stress at Break 6.1 MPa ISO 527-1/-2 or ISO 37
Elongation at Break 432% ISO 527-1/-2 or ISO 37
Compression Set, 23°C / 168 h 23.7% ISO 815
Compression Set, 70°C / 24 h 27% ISO 815
Compression Set, 125°C / 24 h 34% ISO 815
Compression Set, 125°C / 70 h 44% ISO 815
Shore A Hardness 71 ISO 48-4 / ISO 868

These current grade-specific values make Santoprene 281-64MED especially relevant to flexible medical parts where repeated deformation and compression recovery matter.

Medical Biocompatibility of Santoprene 281-64MED

A major advantage of Santoprene 281-64MED is the medical biocompatibility program behind the material.

Celanese lists Santoprene 281-64MED in its medical biocompatibility testing matrix with testing corresponding to:

Biological / Medical Test Standard
Cytotoxicity ISO 10993-5
Muscle Implantation USP Class VI / ISO 10993-6
Intracutaneous Testing USP Class VI / ISO 10993-10
Maximization Sensitization ISO 10993-10
Systemic Toxicity USP Class VI / ISO 10993-11
Heavy Metals USP 381
Extractable Heavy Metals EP Monograph 3.2.9

Celanese notes that ISO 10993 and USP Class VI testing is conducted on representative MED grades, while cytotoxicity and heavy-metal testing is performed annually on representative grades.

USP Class VI & ISO 10993 Support

Santoprene 281-64MED is part of Celanese’s medical TPV family supported by biocompatibility testing corresponding to USP Class VI and ISO 10993.

This makes the grade relevant for medical-device manufacturers developing:

  • Drug-delivery equipment
  • Pump systems
  • Medical seals
  • Pharmaceutical components
  • Flexible tubing
  • Connectors
  • Diagnostic equipment
  • Healthcare components

The regulatory support is one of the major reasons to use a dedicated MED grade rather than a general-purpose Santoprene TPV.

FDA Drug Master File Support

Celanese lists active U.S. FDA Drug Master File 17690 for the Santoprene 181 / 281 MED grades.

For customers developing pharmaceutical or drug-delivery products, this can support regulatory submissions by allowing confidential material information to be referenced through the manufacturer’s Drug Master File.

This is especially relevant to:

  • Drug-delivery systems
  • Pharmaceutical packaging
  • Syringe components
  • Medical closures
  • Pump components
  • Combination products

Sterilization Compatibility

Celanese lists Santoprene 281-64MED as compatible with the three major sterilization routes shown in its medical-grade portfolio:

Sterilization Method Santoprene 281-64MED
Steam Compatible
Gamma Radiation Compatible
Ethylene Oxide (ETO) Compatible

Celanese also reports broader Santoprene medical-grade testing involving steam at 134°C, ethylene oxide and gamma radiation up to 50 kGy for relevant medical materials.

Actual finished-part sterilization conditions should be selected according to device design, exposure duration, number of cycles and regulatory requirements.

Peristaltic Pump Tubing

Santoprene 281-64MED has a particularly strong application story in peristaltic pump tubing.

Celanese specifically highlights this grade for flexible pump tubing because of:

  • High resiliency
  • Excellent flex-fatigue resistance
  • Biocompatibility
  • Sterilizability
  • Low permeation
  • High elasticity
  • Good performance with barbed fittings

Peristaltic pump tubing is repeatedly compressed by rollers during operation, so a material must recover its shape consistently over a large number of cycles.

Celanese’s published compression-stress-relaxation work for Santoprene 281-64MED evaluates force retention over extended time using ISO 3384 testing, reinforcing its positioning for cyclic pump-tubing applications.

Polyolefin Bonding

Celanese lists Polyolefin as the compatible bonding substrate for Santoprene 281-64MED.

This can be useful for:

  • Two-component injection molding
  • Overmolded medical components
  • Integrated seals
  • Medical-device housings
  • Flexible interfaces molded onto polyolefin parts

Actual adhesion depends on the specific substrate, component design and processing conditions.

Why Choose Santoprene 281-64MED?

The main reason to select Santoprene 281-64MED is its balance of medical regulatory support, mechanical durability and elastomeric flexibility.

At approximately 71 Shore A, the material provides more mechanical support than very soft TPVs while remaining sufficiently flexible for tubing, seals, gaskets and repeated-flex medical components.

Its approximately 432% elongation at break supports substantial deformation, while 6.1 MPa tensile strength provides useful mechanical durability.

Compression-set values of approximately 23.7% at 23°C / 168 h and 27% at 70°C / 24 h are particularly relevant to sealing and pump applications.

More importantly, the grade combines:

  • Medical-grade TPV formulation
  • USP Class VI / ISO 10993 biocompatibility support
  • FDA Drug Master File support
  • Steam sterilization compatibility
  • Gamma sterilization compatibility
  • ETO sterilization compatibility
  • Excellent flex-fatigue resistance
  • Injection and extrusion processability

For customers requiring a 71A medical-grade TPV for peristaltic pump tubing, medical seals, drug-delivery components or healthcare equipment, Santoprene 281-64MED is a particularly relevant grade to evaluate.

Processing Guidelines for Santoprene 281-64MED

Santoprene 281-64MED is shear dependent and can be processed on conventional thermoplastic equipment.

Current Celanese data lists:

  • Injection molding
  • Multi-injection molding
  • Extrusion
  • Sheet extrusion
  • Coextrusion

Current Grade-Specific Injection Conditions

Processing Parameter Celanese Guidance
Drying Recommended Yes
Drying Temperature 80°C
Drying Time ≥3 hours
Processing Moisture Content ≤0.08%
Optimum Melt Temperature 210°C
Minimum Melt Temperature 190°C
Maximum Melt Temperature 230°C
Optimum Mold Temperature 30°C
Minimum Mold Temperature 10°C
Maximum Mold Temperature 50°C

These values come from the Celanese Materials Database sheet revised April 21, 2025.

Injection Molding Notes

For injection molding, processors should optimize:

  • Melt temperature
  • Injection speed
  • Screw speed
  • Holding pressure
  • Back pressure
  • Gate dimensions
  • Runner design
  • Mold temperature
  • Venting
  • Cooling time

Because Santoprene 281-64MED is shear dependent, higher shear can reduce apparent melt viscosity and improve mold filling.

Extrusion Processing

Santoprene 281-64MED is also specifically designed for extrusion applications.

Important variables include:

  • Barrel temperature profile
  • Screw geometry
  • Screw speed
  • Adapter temperature
  • Die temperature
  • Melt pressure
  • Draw-down ratio
  • Cooling conditions
  • Tubing dimensions
  • Wall-thickness control
  • Surface finish

For medical and pharmaceutical production, cleanliness, material handling and manufacturing controls should be aligned with the customer’s quality system.

Related Products

We supply Santoprene TPV grades for different medical, healthcare, pharmaceutical, hardness and processing requirements.

Typical Santoprene medical product families include:

  • Santoprene 281 MED Series
  • Santoprene 181 MED Series
  • Santoprene 8281 MED Series
  • Santoprene 8181 MED Series
  • Santoprene medical tubing grades
  • Santoprene medical sealing grades
  • Santoprene drug-delivery grades
  • Santoprene pharmaceutical grades
  • Santoprene healthcare TPV grades

View More TPV Thermoplastic Vulcanizates →

For grade-selection support, send us your required hardness, sterilization method, biological evaluation requirements, application and processing method.

Technical Documents for Santoprene 281-64MED

Document Type Description
TDS Current physical, mechanical and processing data
SDS Safety Data Sheet
USP Class VI Information Medical biocompatibility testing information
ISO 10993 Information Biological evaluation information
FDA DMF Information Drug Master File 17690 support
Sterilization Information Steam, gamma and ETO compatibility
Peristaltic Pump Information Pump-tubing application and compression-relaxation data
Processing Guide Injection molding and extrusion guidance
Medical Product Guide Santoprene MED portfolio information
COA Batch-specific quality information where available

Need technical documents for Santoprene 281-64MED?

📧 Email: ruiqingchem@gmail.com

📝 Online form: Contact Us →

Please state Santoprene 281-64MED and specify whether you require TDS, SDS, USP Class VI, ISO 10993, FDA DMF, sterilization or peristaltic-pump information.

FAQ About Santoprene 281-64MED

Q1: What is Santoprene 281-64MED?

Santoprene 281-64MED is a natural medical-grade thermoplastic vulcanizate from Celanese developed for healthcare, medical-device, pharmaceutical and drug-delivery applications.

Q2: What is the hardness of Santoprene 281-64MED?

The current Celanese medical-grade data lists approximately 71 Shore A.

Q3: What is the density?

The typical density is approximately 0.950 g/cm³.

Q4: What is the tensile strength?

Typical tensile stress at break is approximately 6.1 MPa.

Q5: What is the elongation at break?

Typical elongation at break is approximately 432%.

Q6: What is the tensile stress at 100% elongation?

The typical value is approximately 2.7 MPa.

Q7: What is the compression set?

Current Celanese data lists approximately 23.7% at 23°C / 168 h, 27% at 70°C / 24 h, 34% at 125°C / 24 h and 44% at 125°C / 70 h.

Q8: Does Santoprene 281-64MED have USP Class VI support?

Yes. Celanese includes Santoprene 281-64MED in its MED biocompatibility testing matrix corresponding to USP Class VI and ISO 10993.

Q9: Is Santoprene 281-64MED ISO 10993 tested?

Yes. Celanese lists testing covering cytotoxicity, implantation, intracutaneous response, sensitization and systemic toxicity for the MED medical-grade program.

Q10: Does it have an FDA Drug Master File?

Celanese lists active U.S. FDA DMF 17690 for the Santoprene 181/281 MED family.

Q11: Is Santoprene 281-64MED suitable for peristaltic pump tubing?

Yes. Celanese specifically publishes Santoprene 281-64MED as a material solution for peristaltic pump tubing, highlighting resiliency, flex-fatigue resistance and elasticity.

Q12: Can Santoprene 281-64MED be steam sterilized?

Yes. Steam sterilization is listed for the grade in Celanese’s medical portfolio.

Q13: Is it compatible with gamma radiation sterilization?

Yes. Gamma sterilization is listed as compatible for Santoprene 281-64MED.

Q14: Can Santoprene 281-64MED be sterilized with ETO?

Yes. Ethylene oxide (ETO) is also listed as a compatible sterilization method.

Q15: Can Santoprene 281-64MED be injection molded and extruded?

Yes. Current Celanese information lists injection molding, multi-injection molding, extrusion, sheet extrusion and coextrusion.

Q16: What processing temperatures are recommended?

Current Celanese guidance lists an optimum melt temperature of approximately 210°C, with a range of 190–230°C, and an optimum mold temperature of about 30°C, with a range of 10–50°C.

Request Santoprene 281-64MED Price & Technical Support

For pricing, availability, technical documents or application support for Santoprene 281-64MED, please provide:

  • Required quantity
  • Destination country or port
  • Medical-device, pump-tubing or pharmaceutical application
  • Required Shore hardness
  • Patient-contact or fluid-contact condition
  • Required ISO 10993 testing
  • USP Class VI requirement
  • FDA DMF documentation requirement
  • Sterilization method: steam / gamma / ETO
  • Repeated-flex or peristaltic-pump requirement
  • Operating temperature
  • Injection-molding or extrusion process
  • Bonding / overmolding substrate
  • TDS / SDS requirement
  • COA requirement
  • Sample requirement, if applicable

📧 Email: ruiqingchem@gmail.com

📝 Send Inquiry →

Technical Documents

Download technical data sheets, safety data sheets and certificates for this material.

TDS Files

Technical document available for review or download.

0 Files
No TDS file uploaded yet.

MSDS Files

Technical document available for review or download.

0 Files
No MSDS file uploaded yet.