描述
MacDermid Alpha Micromax 5874 Ag/AgCl Reference Electrode Ink
Type: Ag/AgCl Ink
Application: Reference / Counter Electrode
Ag:AgCl: 65 / 35
Shelf Life: 3 months
Micromax 5874 is a solvent-based silver/silver chloride composition designed for screen printing on polyester. It is suitable for use as a reference or counter electrode for electrochemical sensors, for iontophoretic anodes and cathodes, or for a variety of biomedical applications. The product offers low electrode polarization, high stability reference potential, high solids for printing thick electrodes, fast drying, and equal electrode capacity for iontophoretic anode and cathode.
Micromax 5874 from MacDermid Alpha is a solvent-based silver/silver chloride composition developed for screen printing on polyester. It is designed as a reference or counter electrode for electrochemical sensors, and is also suitable for iontophoretic anodes and cathodes as well as a range of biomedical applications. The Ag:AgCl ratio is 65/35, and the high solids content supports printing thick electrodes for stable performance.
The paste carries 83.4–86.4% solids, density 3.39 g/cm³, and a viscosity range of 23–35 Pa.s. Micromax 3610 is the listed solvent or thinner. Only print-treated polyester film substrate should be used. Micromax 5874 can also be printed over silver (Micromax 5000, 5025) or over carbon (Micromax 7102). Care should be taken to minimize contact of silver/silver chloride compositions with metals, especially reactive metals such as aluminum or brass; no contact should occur. Components made of these materials can be protected by taping or covering with an inert material. It is best to use a polyester screen when printing to minimize contact with reactive metals.
Mix thoroughly with a plastic or stainless-steel spatula before use. If severe settling is found after long storage, mix and then jar-roll the ink sample overnight before use. Drying is 1–2 minutes in well-ventilated ovens or conveyor dryers at 120°C, or 3–5 minutes in a box oven at 120°C. Clean-up uses ethylene glycol diacetate or dipropylene glycol methyl ether. Typical physical properties include coat weight of 11 mg/cm² on a 160-mesh screen, with Ag depletion (anode) and AgCl depletion (cathode) each exceeding 40 minutes. Store sealed at 5–30°C; unopened shelf life is 3 months.
Genuine MacDermid Alpha Micromax Imported Stock & Technical Support
We hold regular stock of authentic MacDermid Alpha Micromax 5874 Ag/AgCl ink. Original factory TDS and batch-specific COA are available on request for your electrochemical sensor and biomedical programs.
Request Sample, TDS & Quotation
Complete TDS, COA, and regulatory documentation available
Key Features of MacDermid Alpha Micromax 5874
- Solvent-based silver/silver chloride composition for screen printing on polyester
- Ag:AgCl ratio 65/35 for consistent electrochemical behavior
- Low electrode polarization for stable sensor readings
- High stability reference potential for reference electrode use
- High solids for printing thick electrodes
- Fast drying: 1–2 minutes at 120°C in oven or conveyor dryer
- Equal electrode capacity for iontophoretic anode and cathode
- Can be printed over silver (Micromax 5000, 5025) or carbon (Micromax 7102)
- Density 3.39 g/cm³; solids 83.4–86.4%; viscosity 23–35 Pa.s
- Coat weight 11 mg/cm² on 160-mesh screen
- Ag depletion (anode) and AgCl depletion (cathode) each >40 minutes
- Clean-up: ethylene glycol diacetate or dipropylene glycol methyl ether
Primary Applications
- Electrochemical sensors — reference or counter electrode layer
- Iontophoretic devices — anodes and cathodes with equal electrode capacity
- Biomedical applications — printed Ag/AgCl electrode layers on polyester
- Printed biosensors — where stable reference potential is required
Full Technical Specifications
| Property | Typical Value | TDS Reference |
| Product Type | Solvent-based Ag/AgCl composition for screen printing | TDS: Silver/Silver Chloride Composition for Screen Printing |
| Application | Membrane switch conductor (per TDS table); reference/counter electrode for electrochemical sensors, iontophoretic anodes and cathodes, biomedical applications | TDS: Product Description |
| Solvent or Thinner | Micromax 3610 | TDS: Micromax 3610 |
| Density | 3.39 g/cm³ | TDS: 3.39 g/cm³ |
| Solid Content | 83.4 to 86.4 % | TDS: 83.4 to 86.4 % |
| Ag:AgCl Ratio | 65 / 35 | TDS: 65 / 35 |
| Viscosity | 23 to 35 Pa.s | TDS: Brookfield 0.5 RVT, SC4-14/6R, 10 rpm, 25°C |
| Substrate | Print-treated polyester film only | TDS: Substrate |
| Compatible Underlayers | Micromax 5000, 5025 (silver) or Micromax 7102 (carbon) | TDS: Equipment consideration |
| Screen Type | Polyester screen recommended to minimize contact with reactive metals | TDS: Printing |
| Drying (Oven or Conveyor, 120°C) | 1 to 2 minutes | TDS: Drying |
| Drying (Box Oven, 120°C) | 3 to 5 minutes | TDS: Drying |
| Coat Weight (160-mesh screen) | 11 mg/cm² | TDS: Typical Physical and Composition Properties |
| Ag Depletion (Anode) | > 40 minutes | TDS: Typical Physical and Composition Properties |
| AgCl Depletion (Cathode) | > 40 minutes | TDS: Typical Physical and Composition Properties |
| Low Electrode Polarization | Yes | TDS: Product benefits |
| High Stability Reference Potential | Yes | TDS: Product benefits |
| Fast Drying | Yes | TDS: Product benefits |
| Equal Electrode Capacity for Anode and Cathode | Yes (iontophoretic) | TDS: Product benefits |
| Clean-up Solvent | Ethylene glycol diacetate or dipropylene glycol methyl ether | TDS: Clean-up solvent |
| Shelf Life | 3 months | TDS: 3 months |
| Storage Temperature | 5 – 30 °C | TDS: 5°C – 30°C |
Note: All listed values are typical and may vary by batch. Values based on MacDermid Alpha official TDS. Independent qualification testing is required prior to production use.
Recommended Processing Conditions
| Parameter | Recommended Value | TDS Reference |
| Mixing Prior to Use | Mix thoroughly with a plastic or stainless-steel spatula. If severe settling is found after long storage, mix and then jar-roll overnight before use | TDS: Printing |
| Screen Type | Polyester screen recommended to minimize contact with reactive metals | TDS: Printing |
| Substrate | Print-treated polyester film only | TDS: Substrate |
| Compatible Underlayers | Silver (Micromax 5000, 5025) or carbon (Micromax 7102) | TDS: Equipment consideration |
| Reactive Metal Contact | Minimize; no contact with aluminum or brass. Protect such components by taping or covering with an inert material | TDS: Equipment consideration |
| Drying (Oven or Conveyor, 120°C) | 1 to 2 minutes | TDS: Drying |
| Drying (Box Oven, 120°C) | 3 to 5 minutes | TDS: Drying |
| Clean-up Solvent | Ethylene glycol diacetate or dipropylene glycol methyl ether | TDS: Clean-up solvent |
| Thinner | Micromax 3610 | TDS: Micromax 3610 |
Handling and Storage Recommendations
| Storage Rules | Store tightly sealed in a clean, stable environment at 5-30°C. | TDS: 5°C – 30°C |
| Shelf Life | 3 months in unopened containers from date of shipment. | TDS: 3 months |
| Pre-use Preparation | Thoroughly mix prior to use. Some settling of solids may occur during storage. | TDS: thoroughly mix |
| Transportation | Under normal shipping conditions, no temperature control is expected. For extended transport periods, confirm product suitability. | TDS: normal shipping conditions |
Official Technical Documentation
| Document Type | Document Introduction | Document Request |
| TDS | MacDermid Alpha Micromax 5874 original factory technical data sheet | Request TDS |
| COA | Batch-specific certificate of analysis | Request COA |
| SDS | Safety Data Sheet for handling and storage | Request SDS |
Frequently Asked Questions
What type of electrode applications is 5874 designed for?
The TDS positions 5874 as a reference or counter electrode for electrochemical sensors, and also suitable for iontophoretic anodes and cathodes, or for a variety of biomedical applications. Low electrode polarization and high stability reference potential are listed as product benefits.
What is the Ag:AgCl ratio in 5874 and why does it matter?
The TDS lists the Ag:AgCl ratio as 65/35. This ratio determines the electrochemical balance of the printed layer, and 5874 is also noted for equal electrode capacity between iontophoretic anode and cathode.
Can 5874 be printed over silver or carbon layers?
Yes. 5874 can be printed over silver (Micromax 5000, 5025) or over carbon (Micromax 7102). Use a polyester screen when printing to minimize contact with reactive metals, and avoid any contact with aluminum or brass.
What substrate does 5874 require?
Only print-treated polyester film substrate should be used. Substrates of different composition or from different manufacturers may result in variations in performance, so qualification on the target substrate is recommended.
Why is metal contact a concern with Ag/AgCl inks?
The TDS advises minimizing contact of silver/silver chloride compositions with metals, especially reactive metals such as aluminum or brass. Components made of these materials can be protected by taping or covering with an inert material.
How should 5874 be mixed before printing?
Mix thoroughly with a plastic or stainless-steel spatula before use. If severe settling is found after long storage, mix and then jar-roll the ink sample overnight before use.
How should 5874 be stored?
Store tightly sealed at 5–30°C in a clean, stable environment. Unopened shelf life is 3 months from shipment. Some settling may occur, so mix thoroughly before reuse.
Get MacDermid Alpha Micromax 5874 Bulk Pricing and Technical Support
We supply authentic MacDermid Alpha Micromax 5874 Ag/AgCl ink for electrochemical sensor and biomedical programs. Contact our team for bulk quotations, sample availability, technical documentation, and application support.
Inquire Bulk Price & Technical Support
Disclaimer: All technical data on this page are for general guidance only and are not product specifications. Buyers must carry out independent trials and verify suitability before bulk ordering. Actual values may vary between production lots.