描述
NORYL ENV105 Resin is a non-reinforced blend of polyphenylene ether (PPE) and high impact polystyrene (HIPS), manufactured by SABIC. This impact modified extrusion grade exhibits high heat resistance, with a Vicat softening point B/120 of 115°C, and carries UL94 V-1 flame rating at 1.5mm as well as NFP 92501-1 M1 and M2 certifications.
NORYL ENV105 Resin is an excellent candidate for extrusion electrical applications. It is particularly suitable for wire and cable insulation and sheathing as a halogen-free flame retardant alternative to PVC, offering good flexibility and processability. Physical property data is determined using test methods established by ASTM International and ISO, the globally recognized standards organizations.
For more NORYL grades and technical information, please visit our PPO/PPE product page.
Key Features of NORYL ENV105 Resin
-
Non-Reinforced PPE/HIPS Blend – Unfilled formulation for balanced performance
-
Impact Modified – Excellent impact resistance for demanding applications requiring toughness
-
High Heat Resistance – Vicat softening point of 115°C (ISO 306 B/120)
-
UL94 V-1 Flame Rating – V-1 at 1.5mm thickness
-
NFP M1/M2 Certified – Complies with NFP 92501-1 M1 and M2 standards
-
Very Low Moisture Absorption – 0.06%–0.2% water absorption; maintains properties in humid environments
-
Good Dimensional Stability – Low shrinkage, creep resistance, and low warpage
-
Halogen-Free Flame Retardant – Non-brominated, non-chlorinated system
-
Excellent Electrical Insulation Properties – Low dielectric constant, high volume resistivity, stable across wide temperature and frequency ranges
-
Extrusion Grade – Specifically designed for extrusion processing
-
Good Flexibility & Processability – Suitable alternative to PVC for wire and cable applications
-
RoHS Compliant – Meets global environmental standards
Typical Applications for NORYL ENV105 Resin
| Industry | Typical Components & Considerations |
|---|---|
| Wire & Cable | Wire and cable insulation, sheathing – halogen-free flame retardant alternative to PVC, good flexibility and processability |
| Electrical & Electronics | Extruded electrical components, coil formers, relay boxes, insulating supports |
| Automotive | Automotive components |
| Water Management | Water/fluid handling components |
| Home Appliances & Office Equipment | Appliance and office equipment housings and precision parts |
Typical Properties of NORYL ENV105 Resin
| Property | Value | Test Method |
|---|---|---|
| Density | 1.10 g/cm³ | ISO 1183 |
| Tensile Stress, Yield (50 mm/min) | 50 MPa | ISO 527 |
| Tensile Stress, Break (50 mm/min) | 40 MPa | ISO 527 |
| Tensile Strain, Yield (50 mm/min) | 4% | ISO 527 |
| Tensile Strain, Break (50 mm/min) | 10% | ISO 527 |
| Tensile Modulus (1 mm/min) | 2000 MPa | ISO 527 |
| Flexural Stress (2 mm/min) | 60 MPa | ISO 178 |
| Flexural Modulus (2 mm/min) | 1700 MPa | ISO 178 |
| Notched Izod Impact (23°C) | 25 kJ/m² | ISO 180/1A |
| Notched Izod Impact (-30°C) | 20 kJ/m² | ISO 180/1A |
| Vicat Softening Temperature B/120 | 115°C | ISO 306 |
| HDT @ 1.80 MPa | Refer to full TDS | ISO 75-1/-2 |
| Volume Resistivity | High | IEC 60093 |
| Dielectric Strength | Refer to full TDS | IEC 60243-1 |
| Relative Permittivity (50/60 Hz) | Refer to full TDS | IEC 60250 |
| Flammability (1.5mm) | V-1 | UL 94 |
| NFP 92501-1 | M1 / M2 | NFP |
Important Notes on Typical Data:
Values listed are typical and sourced from manufacturer data sheets. They do not constitute binding product specification.
Batch-to-batch deviations may exist. For critical applications, validate performance with batch-specific COA certificate.
Final performance depends on processing conditions and part design.
Manufacturer official TDS shall serve as definitive technical reference. Request the latest official TDS from our sales team.
Processing Guidelines for NORYL ENV105 Resin
| Step | Process |
|---|---|
| Drying Temperature | Refer to full TDS for specific drying conditions |
| Drying Time | Refer to full TDS |
| Suggested Max Moisture | Refer to full TDS |
| Rear Zone Temperature | Refer to full TDS |
| Middle Zone Temperature | Refer to full TDS |
| Front Zone Temperature | Refer to full TDS |
| Adapter Temperature | Refer to full TDS |
| Melt Temperature | Refer to full TDS |
| Die Temperature | Refer to full TDS |
| Process | Extrusion |
| Storage | Store in original, sealed packaging in a cool, dry place away from direct sunlight |
Critical Processing Warnings:
Extrusion: NORYL ENV105 is specifically designed for extrusion processing.
Drying: Proper drying is critical to prevent hydrolysis and achieve optimal mechanical properties.
Storage: Store in original, sealed packaging in a cool, dry place away from direct sunlight.
Related Products
Explore Engineering Plastics – Browse all engineering plastic materials
About Our Company – Learn more about our supply capabilities and quality assurance
Technical Documents for NORYL ENV105 Resin
| Document Type | Description & Source |
|---|---|
| Manufacturer Official TDS | Complete physical, thermal, and mechanical properties of NORYL ENV105 |
| Manufacturer Official SDS | GHS-compliant safety documentation |
| COA (Certificate of Analysis) | Batch-specific quality certification |
| UL Yellow Card | UL safety certification |
| NFP Certification | NFP 92501-1 M1/M2 certification documentation |
Request any document above by:
Email: ruiqingchem@gmail.com
Online form: Our contact page
We reply within one working business day. Please clearly state product (NORYL ENV105) and document type you require.
FAQ about NORYL ENV105 Resin
Q1: What is NORYL ENV105?
A: NORYL ENV105 is a non-reinforced blend of polyphenylene ether (PPE) and high impact polystyrene (HIPS) from SABIC. It is an impact modified extrusion grade with UL94 V-1 flame rating and NFP M1/M2 certification, designed for electrical applications.
Q2: What are the key features of NORYL ENV105?
A: It offers high heat resistance (Vicat B/120 of 115°C), UL94 V-1 flame rating, NFP M1/M2 certification, halogen-free flame retardancy, very low moisture absorption, good dimensional stability, and excellent electrical insulation properties.
Q3: What are the typical applications for NORYL ENV105?
A: Typical applications include wire and cable insulation and sheathing (halogen-free alternative to PVC), extruded electrical components, coil formers, relay boxes, automotive components, and water management components.
Q4: What is the flame rating of NORYL ENV105?
A: UL94 V-1 at 1.5mm thickness, and NFP 92501-1 M1/M2 certified.
Q5: Is NORYL ENV105 halogen-free?
A: Yes, it contains non-brominated, non-chlorinated flame retardant.
Q6: What is the recommended processing method for NORYL ENV105?
A: NORYL ENV105 is designed for extrusion processing.
Q7: What regions is NORYL ENV105 available in?
A: It is available in Europe.
Q8: What is the lead time for orders?
A: Regular orders ship within 7-10 working days after payment confirmation. Large-volume orders can be negotiated separately.
CTA (Call to Action)
Ready to order NORYL ENV105?
To get a precise quotation and professional technical support, please share:
-
Required quantity (kg)
-
Destination port or delivery address
-
Target application (wire & cable, electrical extrusion, etc.)
-
Document requirement (TDS, SDS, COA, UL docs, NFP docs, etc.)
Sample Policy:
-
Samples are for laboratory validation tests only, not for production use.
-
Buyer bears international sample-shipping freight.
-
If bulk-product performance deviates from sample reference, manufacturer official TDS serves as the authoritative benchmark.
Take action now:
-
📧 Email Us – ruiqingchem@gmail.com
-
📝 Send Inquiry – Use our quick inquiry form
-
💬 Live Chat – Click the bottom-right chat widget to speak directly with our team
After-Sales Support
| Service | Details |
|---|---|
| Quality Inspection Period | All quality-related claims must be submitted within 7 working days after delivery, supported by test data and photographic evidence. |
| Return / Exchange Policy | Confirmed product defects caused by our side trigger replacement or refund. Terms and conditions apply. |
| Logistics Damage | Report shipping damage directly to carrier immediately upon goods receipt. We assist with claim-document preparation. |
| Technical Support | Remote technical guidance available. On-site troubleshooting can be arranged upon special request. |
| Export Documentation | We supply commercial invoice, packing list, bill of lading, COA, and additional compliance certificates on request. |
Disclaimer
DISCLAIMER: All technical data is referenced from original manufacturer typical values for NORYL ENV105. Our company acts as authorized distributor/trader rather than original manufacturer. Final performance depends on processing conditions and part design. Buyers shall independently validate product suitability for individual applications. Our firm bears no liability for product failure caused by improper processing or improper usage. Always reference the latest manufacturer official TDS of NORYL ENV105 as the definitive specification.