描述
3M Novec 8200 Engineered Fluid Film Cleaning Solvent
Type: Film Cleaning Solvent
Boiling Point: 76°C
Surface Tension: 13.6 dynes/cm
GWP: 55
Packing: 5KG / 20KG drum
3M Novec 8200 Engineered Fluid is a clear, colorless, low-odor solvent specifically designed for film cleaning applications. Engineered as a replacement for 1,1,1-trichloroethane and perchloroethylene, this proprietary fluid delivers excellent cleaning performance with zero ozone depletion potential and a low GWP of 55. With a boiling point of 76°C and low surface tension of 13.6 dynes/cm, Novec 8200 provides effective cleaning without leaching plasticizer from film substrates, making it ideal for acetate and Estar film cleaning in the motion picture and archival industries.
Novec 8200 offers a superior environmental profile — excluded by the U.S. EPA from VOC definition, certified as a Clean Air Solvent by California's SCAQMD, and not classified as a Hazardous Air Pollutant. Its nonflammable nature, low toxicity (200 ppm exposure guideline), and excellent compatibility with film substrates ensure safe and effective operation in high-speed film cleaning equipment. Optimized for use in Lipsner-Smith CF-9200 film cleaning machines and retrofitted equipment, Novec 8200 achieves running speeds exceeding 220 feet per minute with cleaning efficiency of 75,000 to 85,000 feet per gallon — delivering cost-competitive performance compared to traditional chlorinated solvents.
Genuine 3M Imported Stock and Technical Support
We supply stable spot inventory of genuine 3M Novec 8200 engineered fluid. Official TDS, SDS, and batch COA documents are available for film cleaning and specialty solvent applications.
Request Novec 8200 Quotation, TDS, SDS, and Sample
Complete SDS, COA, and technical documentation available
Core Advantages of 3M Novec 8200 Engineered Fluid
- Film cleaning optimized — specifically designed for acetate and Estar film substrates without leaching plasticizer
- VOC exempt (U.S. EPA) — excluded from VOC definition; negligible contribution to smog formation
- Clean Air Solvent certified — approved by California's South Coast Air Quality Management District
- Low GWP: 55 — environmentally sustainable alternative to chlorinated solvents
- Zero ozone depletion potential — environmentally responsible formulation
- Nonflammable — no flash point, safe for industrial film cleaning operations
- Low toxicity — 200 ppm exposure guideline, practically non-toxic through inhalation
- Excellent equipment compatibility — optimized for Lipsner-Smith CF-9200 and retrofitted film cleaning machines
Main Applications
- Motion picture film cleaning — cleaning of acetate and Estar film substrates
- Archival film preservation — safe cleaning of historical and archival film materials
- Film processing — cleaning during film manufacturing and processing operations
- Replacement for chlorinated solvents — alternative to 1,1,1-trichloroethane and perchloroethylene
- Specialty solvent applications — where low surface tension and material compatibility are critical
Full Technical Parameters
| Property | Typical Value | Test Method |
| Type | Segregated Hydrofluoroether | — |
| Molecular Weight | 264 | — |
| Boiling Point | 76°C | ASTM D1078 |
| Freeze Point | -138°C | ASTM D97 |
| Liquid Density (25°C) | 1.43 g/ml | ASTM D891 |
| Surface Tension | 13.6 dynes/cm | — |
| Vapor Pressure (25°C) | 109 mmHg | — |
| Viscosity (25°C) | 0.61 cP | — |
| Solubility in Water | <20 ppmw | — |
| Water Solubility | 92 ppmw | — |
| Heat of Vaporization | 30 cal/g | — |
| Ozone Depletion Potential | 0.00 | — |
| Global Warming Potential | 55 | — |
| Atmospheric Lifetime | 0.84 years | — |
| Flash Point | None | — |
| Flammability Range in Air | 2.4-12.4% | ASTM E681-94 |
| Exposure Guideline (8hr TWA) | 200 ppm | 3M Medical Dept. |
| Acute Toxicity (4h LC50 Rat) | >92,000 ppm | — |
| VOC Designation | Exempt (U.S. EPA) | — |
| Clean Air Solvent | SCAQMD Certified | — |
Note: All listed figures are typical values and may vary by production batch. Complete independent qualification testing is required before mass production deployment.
Handling and Storage Recommendations
| Storage Rules | Store sealed original containers in a dry, well-ventilated area away from heat sources and direct sunlight. |
| Forbidden Environments | Avoid exposure to open flames, strong oxidizing agents, and reactive metal powders. |
| Operation Protection | Maintain adequate ventilation. Wear nitrile protective gloves and anti-splash safety goggles during handling. |
Official Technical Documentation
| Document Type | Document Introduction | Document Request |
| TDS | 3M Novec 8200 original factory technical data sheet | Request TDS |
| SDS | Safety data sheet covering transport, storage, and handling guidelines | Request SDS |
| COA | Batch-specific certificate of analysis | Request COA |
Frequently Asked Questions
What is 3M Novec 8200 Engineered Fluid?
3M Novec 8200 is a clear, colorless, low-odor engineered fluid designed specifically for film cleaning applications. It replaces 1,1,1-trichloroethane and perchloroethylene, with zero ozone depletion potential and low GWP of 55.
Is Novec 8200 a VOC?
No. Novec 8200 has been excluded by the U.S. EPA from the definition of a VOC based on negligible contribution to tropospheric ozone formation. It is also certified as a Clean Air Solvent by California's SCAQMD.
What is the boiling point of Novec 8200?
Novec 8200 has a boiling point of 76°C, higher than most CFCs, HCFCs, and HFCs, which reduces evaporative losses during film cleaning operations.
Is Novec 8200 compatible with film substrates?
Yes. Novec 8200 demonstrates excellent compatibility with acetate and Estar film substrates, with low propensity to leach plasticizer compared to traditional solvents like perchloroethylene.
What equipment is recommended for Novec 8200?
Novec 8200 is optimized for use in Lipsner-Smith CF-9200 film cleaning machines or retrofitted CF-3000 Mark VI and higher equipment. It can achieve running speeds exceeding 220 feet per minute.
Is Novec 8200 flammable?
No. Novec 8200 is nonflammable with no flash point, providing safe operation in film cleaning applications.
What is the exposure guideline for Novec 8200?
Novec 8200 has an 8-hour time-weighted average exposure guideline of 200 ppm, with a 4-hour rat LC50 of >92,000 ppm.
Related 3M Novec Engineered Fluids
Compare 3M Novec engineered fluids for different cleaning and application requirements.
| Product Grade | Boiling Point | GWP | VOC Status | Core Application |
| Novec 8200 | 76°C | 55 | Exempt | Film cleaning |
| Novec 7200 | 76°C | 55 | Exempt | Vapor degreasing |
| Novec 7100 | 61°C | 320 | Exempt | Solvent cleaning, heat transfer |
Get 3M Novec 8200 Bulk Pricing and Technical Support
We supply genuine 3M Novec 8200 engineered fluid for film cleaning, archival preservation, and specialty solvent applications. Contact us for bulk pricing, sample availability, technical documents, and application support.
Request Novec 8200 Technical Details
Disclaimer: All technical data on this page are for general guidance only and are not product specifications. Buyers must carry out independent trials and verify suitability before bulk ordering. Actual values may vary between production lots.